Reproducibility of peak moment for isometric and isokinetic knee extension exercise

被引:1
|
作者
Zoeger, Manfred [1 ,2 ,3 ]
Nimmerichter, Alfred [1 ,2 ]
Baca, Arnold [2 ]
Wirth, Klaus [1 ]
机构
[1] Univ Appl Sci Wiener Neustadt, Training & Sports Sci, Johannes Gutenberg Str 3, A-2700 Wiener Neustadt, Austria
[2] Univ Vienna, Ctr Sport Sci & Univ Sports, Schmelz 6, A-1150 Vienna, Austria
[3] Univ Vienna, Doctoral Sch Pharmaceut Nutr & Sport Sci, Josef Holaubek Pl 2, A-1090 Vienna, Austria
关键词
Reproducibility; Isomed; 2000; Dynamometer; Isometric; Isokinetic; TEST-RETEST RELIABILITY; STRENGTH; FLEXION; DYNAMOMETRY; BASKETBALL; IMBALANCE; PROTOCOL; BIODEX; INJURY;
D O I
10.1186/s13102-023-00788-z
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
BackgroundAccurate measurements of muscular performance are important for diagnostics, for example during rehabilitation after traumatic injuries but also in competitive sports. For these purposes, dynamometric devices are widely used and considered the gold standard for muscle strength testing. However, few previous studies have tested the reproducibility of peak moment (PM) at velocities close to the maximum device capability, and in general, reproducibility results cannot be transferred to other devices or test protocols. The purpose of this study was to evaluate the reproducibility of PM for different isometric and isokinetic knee extension exercises using the IsoMed 2000.MethodsThirty subjects volunteered in three repeated test sessions, including isometric knee extension (100 degrees and 140 degrees knee angle) and isokinetic knee extension (30 degrees/s and 400 degrees/s). Statistical analysis for comparison of sessions two and three included paired sample t-test, calculation of intraclass correlation coefficient (ICC) and standard error of measurement (SEM). Additionally, Bland Altman statistics and corresponding plots were created.ResultsA significant difference between sessions in PM was found for isometric knee extension in one leg (140 degrees left). Reproducibility was high for all conditions with ICC ranging from 0.964 to 0.988 and SEM in the range of 7.6 to 10.5 Nm. Bland Altman statistics revealed a bias between - 7.3 and 0.7 Nm.ConclusionsReproducibility of PM using the IsoMed 2000 was good after an initial familiarization trial with high values of relative reproducibility. Absolute reproducibility can be interpreted as appropriate for most common practical applications.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Reproducibility of peak moment for isometric and isokinetic knee extension exercise
    Manfred Zöger
    Alfred Nimmerichter
    Arnold Baca
    Klaus Wirth
    BMC Sports Science, Medicine and Rehabilitation, 15
  • [2] Reproducibility of peak force for isometric and isokinetic multi-joint leg extension exercise
    Zoeger, Manfred
    Nimmerichter, Alfred
    Baca, Arnold
    Wirth, Klaus
    BMC SPORTS SCIENCE MEDICINE AND REHABILITATION, 2025, 17 (01):
  • [3] Inertial effects on moment curves and angle of peak moment during isokinetic knee extension
    Iossifidou, AN
    Baltzopoulos, V
    ISOKINETICS AND EXERCISE SCIENCE, 1998, 7 (02) : 87 - 93
  • [4] Calculation of knee joint moment in isometric and isokinetic knee motion
    Yoonsu Nam
    Seongnam Kim
    So-Ra Baek
    International Journal of Precision Engineering and Manufacturing, 2011, 12 : 921 - 924
  • [5] Calculation of Knee Joint Moment in Isometric and Isokinetic Knee Motion
    Nam, Yoonsu
    Kim, Seongnam
    Baek, So-Ra
    INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2011, 12 (05): : 921 - 924
  • [6] Reproducibility for isometric and isokinetic maximum knee flexion and extension measurements using the IsoMed 2000-dynamometer
    Dirnberger, Johannes
    Wiesinger, Hans-Peter
    Koesters, Alexander
    Mueller, Erich
    ISOKINETICS AND EXERCISE SCIENCE, 2012, 20 (03) : 149 - 153
  • [7] Detection of submaximal effort in isometric and isokinetic knee extension tests
    Lin, PC
    Robinson, ME
    Carlos, J
    OConnor, P
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1996, 24 (01): : 19 - 24
  • [8] TORQUE CURVES PRODUCED AT THE KNEE DURING ISOMETRIC AND ISOKINETIC EXERCISE
    SCUDDER, GN
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1980, 61 (02): : 68 - 73
  • [9] EVALUATION OF MOMENT-ANGLE CURVES IN ISOKINETIC KNEE EXTENSION
    BOBBERT, MF
    HARLAAR, J
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1993, 25 (02): : 251 - 259
  • [10] Factors influencing the reproducibility of isokinetic knee flexion and extension test findings
    Alt, Tobias
    Knicker, Axel J.
    Strueder, Heiko K.
    ISOKINETICS AND EXERCISE SCIENCE, 2014, 22 (04) : 333 - 342