Metal artifact reduction around cervical spine implant using diffusion tensor imaging at 3T: A phantom study

被引:0
作者
Tounekti, Slimane [1 ,8 ]
Alizadeh, Mahdi [2 ]
Middleton, Devon [1 ]
Harrop, James S.
Hiba, Bassem [3 ]
Krisa, Laura [4 ]
Mekkaoui, Choukri [5 ,6 ,7 ]
Mohamed, Feroze B. [1 ]
机构
[1] Thomas Jefferson Univ, Dept Radiol, Philadelphia, PA USA
[2] Thomas Jefferson Univ, Dept Neurosurg, Philadelphia, PA USA
[3] Univ Lyon 1, Inst Sci Cognit, CNRS UMR 5229, Lyon, France
[4] Thomas Jefferson Univ, Dept Phys Therapy, Philadelphia, PA USA
[5] Harvard Med Sch, Boston, MA USA
[6] Massachusetts Gen Hosp, Dept Radiol, Boston, MA USA
[7] AA Martinos Ctr Biomed Imaging, Charlestown, MA USA
[8] Thomas Jefferson Univ, Jefferson Integrated Magnet Resonance Imaging Ctr, Dept Radiol, 909 Walnut St, Philadelphia, PA 19107 USA
基金
美国国家卫生研究院;
关键词
Diffusion tensor imaging; Metal implant; Metal artifacts; Geometric distortion; 3; Tesla; RESOLUTION; CORD; MRI; DWI; EPI;
D O I
10.1016/j.mri.2023.11.007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Diffusion MRI continues to play a key role in non-invasively assessing spinal cord integrity and pre-operative injury evaluation. However, post-operative Diffusion Tensor Imaging (DTI) acquisition of patients with metal implants results in severe geometric distortion. We propose and demonstrate a method to alleviate the technical challenges facing the acquisition of DTI on post-operative cases and longitudinal evaluation of therapeutics.Material and methods: The described technique is based on the combination of the reduced Field-Of-View (rFOV) strategy and the phase segmented EPI, termed rFOV-PS-EPI. A custom-built phantom based on a cervical spine model with metal implants was used to collect DTI data at 3 Tesla scanner using: rFOV-PS-EPI, reduced Field-Of-View single-shot EPI (rFOV-SS-EPI), and conventional full FOV techniques including SS-EPI, PS-EPI, and readout-segmented EPI (RS-EPI). Geometric distortion, SNR, and signal void were assessed to evaluate images and compare the sequences. A two-sample t-test was performed with p-value of 0.05 or less to indicate statistical significance.Results: The reduced FOV techniques showed better capability to reduce distortions compared to the Full FOV techniques. The rFOV-PS-EPI method provided DTI images of the phantom at the level of the hardware whereas the conventional rFOV-SS-EPI is useful only when the metal is approximately 20 mm away. In addition, compared to the rFOV-SS-EPI technique, the suggested approach produced smaller signal voids area as well as significantly reduced geometric distortion in Circularity (p < 0.005) and Eccentricity (p < 0.005) measurements. No statistically significant differences were found for these geometric distortion measurements between the rFOV-PS-EPI DTI sequence and conventional structural T2 images (p > 0.05).Conclusion: The combination of rFOV and a phase-segmented acquisition approach is effective for reducing metal-induced distortions in DTI scan on spinal cord with metal hardware at 3 T.
引用
收藏
页码:57 / 66
页数:10
相关论文
共 41 条
  • [1] Diffusion-weighted interleaved echo-planar imaging with a pair of orthogonal navigator echoes
    Butts, K
    deCrespigny, A
    Pauly, JM
    Moseley, M
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (05) : 763 - 770
  • [2] Human brain diffusion tensor imaging at submillimeter isotropic resolution on a 3 Tesla clinical MRI scanner
    Chang, Hing-Chiu
    Sundman, Mark
    Petit, Laurent
    Guhaniyogi, Shayan
    Chu, Mei-Lan
    Petty, Christopher
    Song, Allen W.
    Chen, Nan-Kuei
    [J]. NEUROIMAGE, 2015, 118 : 667 - 675
  • [3] Interleaved Diffusion-Weighted EPI Improved by Adaptive Partial-Fourier and Multiband Multiplexed Sensitivity-Encoding Reconstruction
    Chang, Hing-Chiu
    Guhaniyogi, Shayan
    Chen, Nan-kuei
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (05) : 1872 - 1884
  • [4] A robust multi-shot scan strategy for high-resolution diffusion weighted MRI enabled by multiplexed sensitivity-encoding (MUSE)
    Chen, Nan-kuei
    Guidon, Arnaud
    Chang, Hing-Chiu
    Song, Allen W.
    [J]. NEUROIMAGE, 2013, 72 : 41 - 47
  • [5] Generic acquisition protocol for quantitative MRI of the spinal cord
    Cohen-Adad, Julien
    Alonso-Ortiz, Eva
    Abramovic, Mihael
    Arneitz, Carina
    Atcheson, Nicole
    Barlow, Laura
    Barry, Robert L.
    Barth, Markus
    Battiston, Marco
    Buechel, Christian
    Budde, Matthew
    Callot, Virginie
    Combes, Anna J. E.
    De Leener, Benjamin
    Descoteaux, Maxime
    de Sousa, Paulo Loureiro
    Dostal, Marek
    Doyon, Julien
    Dvorak, Adam
    Eippert, Falk
    Epperson, Karla R.
    Epperson, Kevin S.
    Freund, Patrick
    Finsterbusch, Juergen
    Foias, Alexandru
    Fratini, Michela
    Fukunaga, Issei
    Wheeler-Kingshott, Claudia A. M. Gandini
    Germani, Giancarlo
    Gilbert, Guillaume
    Giove, Federico
    Gros, Charley
    Grussu, Francesco
    Hagiwara, Akifumi
    Henry, Pierre-Gilles
    Horak, Tomas
    Hori, Masaaki
    Joers, James
    Kamiya, Kouhei
    Karbasforoushan, Haleh
    Kerkovsky, Milos
    Khatibi, Ali
    Kim, Joo-Won
    Kinany, Nawal
    Kitzler, Hagen
    Kolind, Shannon
    Kong, Yazhuo
    Kudlicka, Petr
    Kuntke, Paul
    Kurniawan, Nyoman D.
    [J]. NATURE PROTOCOLS, 2021, 16 (10) : 4611 - 4632
  • [6] High-resolution whole-brain diffusion MRI at 3T using simultaneous multi-slab (SMSlab) acquisition
    Dai, Erpeng
    Liu, Simin
    Guo, Hua
    [J]. NEUROIMAGE, 2021, 237
  • [7] Reproducibility, temporal stability, and functional correlation of diffusion MR measurements within the spinal cord in patients with asymptomatic cervical stenosis or cervical myelopathy
    Ellingson, Benjamin M.
    Salamon, Noriko
    Woodworth, Davis C.
    Yokota, Hajime
    Holly, Langston T.
    [J]. JOURNAL OF NEUROSURGERY-SPINE, 2018, 28 (05) : 472 - 480
  • [8] High-Resolution Diffusion Tensor Imaging With Inner Field-of-View EPI
    Finsterbusch, Juergen
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 29 (04) : 987 - 993
  • [9] Scan time reduction for readout-segmented EPI using simultaneous multislice acceleration: Diffusion-weighted imaging at 3 and 7 Tesla
    Frost, Robert
    Jezzard, Peter
    Douaud, Gwenaelle
    Clare, Stuart
    Porter, David A.
    Miller, Karla L.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (01) : 136 - 149
  • [10] Correlation study of 3T-MR-DTI measurements and clinical symptoms of cervical spondylotic myelopathy
    Gao Si-Jia
    Yuan Xiao
    Jiang Xu-Yuan
    Liu Xiu-Xiang
    Liu Xi-Ping
    Wang Yong-Feng
    Cao Ji-Bin
    Bai Lu-Na
    Xu Ke
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (11) : 1940 - 1945