Electrochemical determination of butylhydroxyanisole (BHA) using a carbon fiber microelectrode modified by electrodeposition of gold nanoparticles and poly-NiTSPc film

被引:2
|
作者
Bougna, Honorine Hortense Tchoumi [1 ]
Njanja, Evangeline [1 ]
Mbokou, Serge Foukmeniok [1 ,2 ]
Tagueu, Raissa Massah [1 ]
Bako, Yibor Fabrice Roland [3 ]
Pontie, Maxime [2 ]
Tonle, Ignas Kenfack [1 ]
机构
[1] Univ Dschang, Dept Chem, Electrochem & Chem Mat, POB 67, Dschang, Cameroon
[2] Univ Angers, Dept Chem, Grp Anal & Proc GA&P, F-49045 Angers 01, France
[3] Ecole Normale Super, Inst Sci & Technol, 01 BP 1757, Ouagadougou, Burkina Faso
关键词
Butylhydroxyanisole; Electrodeposition; Carbon fiber microelectrode; Gold nanoparticles; Nickel(II) tetrasulfonated phthalocyanine; SYNTHETIC PHENOLIC ANTIOXIDANTS; EDIBLE OILS; BUTYLATED HYDROXYANISOLE; VOLTAMMETRIC DETERMINATION; METHOD VALIDATION; SENSOR; FOOD; HYDROXYTOLUENE; OXIDE; TBHQ;
D O I
10.1007/s10800-024-02093-0
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
We present an approach on the electrodeposition of gold nanoparticles (AuNPs) on a carbon fiber microelectrode (CFME) followed by deposition of nickel(II) tetrasulfonated phthalocyanine (p-NiTSPc) film by electropolymerization to form CFME-AuNPs/p-NiTSPc, for the sensitive determination of butylhydroxyanisole (BHA) using cyclic voltammetry (CV) and differential pulse voltammetry (DPV). Atomic force microscopy (AFM), scanning electron microscopy (SEM), and energy-dispersive X-ray spectroscopy (EDX) were used to characterize the topography, morphology, and elemental composition of CFME, CFME-AuNPs, CFME-p-NiTSPc, and CFME-AuNPs/p-NiTSPc, respectively. Additionally, the electrochemical impedance spectroscopy (EIS) technique was employed to evaluate the charge-transfer rate of the tested sensors. To establish the optimal conditions for the electroanalysis of BHA, various parameters were investigated, including the potential scan rate, pH, and electrolysis potential. CFME-AuNPs/p-NiTSPc demonstrated the highest BHA signal, corresponding to the highest active surface area of 0.025 cm2, compared to CFME-p-NiTSPc (0.024 cm2), CFME-AuNPs (0.022 cm2), and CFME (0.021 cm2). In a phosphate buffer solution (PBS, 0.1 M; pH 3), a good linear relationship (R2 = 0.998) was observed between peak current intensities and BHA concentrations in the range of 10-80 mu M, resulting to a detection limit (LOD) of 3.60 mu M (S/N = 3) and a quantification limit (LOQ) of 12 mu M (S/N = 10). The analytical HPLC technique was also tested for BHA determination within the concentration range of 5.55-55.48 mu M and the obtained LOD was calculated to be 4.41 mu M. The potential interference of certain species that could affect the BHA oxidation signal was also evaluated, followed by the application of CFME-AuNPs/p-NiTSPc in real water and Mitosyl ointment samples. The recovery values of BHA were acceptable, ranging from 96 to 99% and demonstrating that the developed sensor is highly sensitive and effective for detecting trace amounts of BHA.
引用
收藏
页码:2121 / 2134
页数:14
相关论文
共 50 条
  • [41] Sensitive simultaneous determination of catechol and hydroquinone using a gold electrode modified with carbon nanofibers and gold nanoparticles
    Zhaohui Huo
    Yanli Zhou
    Qin Liu
    Xulun He
    Yong Liang
    Maotian Xu
    Microchimica Acta, 2011, 173 : 119 - 125
  • [42] Sensitive simultaneous determination of catechol and hydroquinone using a gold electrode modified with carbon nanofibers and gold nanoparticles
    Huo, Zhaohui
    Zhou, Yanli
    Liu, Qin
    He, Xulun
    Liang, Yong
    Xu, Maotian
    MICROCHIMICA ACTA, 2011, 173 (1-2) : 119 - 125
  • [43] Voltammetric determination of Chromium(VI) using a gold film modified carbon composite electrode
    Kachoosangi, Roohollah Torabi
    Compton, Richard G.
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 178 : 555 - 562
  • [44] Electrochemical Behavior and Sensitive Determination of l-Tyrosine with a Gold Nanoparticles Modified Glassy Carbon Electrode
    Hao Cheng
    Changdong Chen
    Shuai Zhang
    Analytical Sciences, 2009, 25 : 1221 - 1225
  • [45] A novel molecularly imprinted electrochemical sensor modified with carbon dots, chitosan, gold nanoparticles for the determination of patulin
    Guo, Wei
    Pi, Fuwei
    Zhang, Hongxia
    Sun, Jiadi
    Zhang, Yinzhi
    Sun, Xiulan
    BIOSENSORS & BIOELECTRONICS, 2017, 98 : 299 - 304
  • [46] Electrochemical determination of tryptophan, uric acid and ascorbic acid at a gold nanoparticles modified carbon paste electrode
    Ghoreishi, Sayed Mehdi
    Behpour, Mohsen
    Saeidinejad, Faezeh
    ANALYTICAL METHODS, 2012, 4 (08) : 2447 - 2453
  • [47] Electrochemical Behavior and Sensitive Determination of L-Tyrosine with a Gold Nanoparticles Modified Glassy Carbon Electrode
    Cheng, Hao
    Chen, Changdong
    Zhang, Shuai
    ANALYTICAL SCIENCES, 2009, 25 (10) : 1221 - 1225
  • [48] Electrochemical Determination of Levofloxacin Using Poly(Pyrogallol Red) Modified Glassy Carbon Electrode
    Kocak, Cagri Ceylan
    Aslisen, Burak
    Karabiberoglu, Sukriye
    Ozdokur, Kemal Volkan
    Aslan, Avni
    Kocak, Suleyman
    CHEMISTRYSELECT, 2022, 7 (41):
  • [49] Electrochemical Determination of Phenazopyridine Hydrocloride using Poly(p-Aminobenzene Sulfonic Acid) Film Modified Glassy Carbon Electrode
    Demirtas, Cigdem
    Yilmaz, Selehattin
    Saglikoglu, Gulsen
    Sadikoglu, Murat
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (02): : 1883 - 1892
  • [50] Determination of Levodopa Using Biosynthesed Gold Nanoparticles/Multiwalled Carbon Nanotubes/L-Cysteine Composite Film Modified Glassy Carbon Electrode
    Yue Weichao
    Cai Zhuo
    Jiang Cuiwen
    Ye Danni
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2014, 35 (02): : 250 - 256