Electrochemical determination of butylhydroxyanisole (BHA) using a carbon fiber microelectrode modified by electrodeposition of gold nanoparticles and poly-NiTSPc film

被引:2
|
作者
Bougna, Honorine Hortense Tchoumi [1 ]
Njanja, Evangeline [1 ]
Mbokou, Serge Foukmeniok [1 ,2 ]
Tagueu, Raissa Massah [1 ]
Bako, Yibor Fabrice Roland [3 ]
Pontie, Maxime [2 ]
Tonle, Ignas Kenfack [1 ]
机构
[1] Univ Dschang, Dept Chem, Electrochem & Chem Mat, POB 67, Dschang, Cameroon
[2] Univ Angers, Dept Chem, Grp Anal & Proc GA&P, F-49045 Angers 01, France
[3] Ecole Normale Super, Inst Sci & Technol, 01 BP 1757, Ouagadougou, Burkina Faso
关键词
Butylhydroxyanisole; Electrodeposition; Carbon fiber microelectrode; Gold nanoparticles; Nickel(II) tetrasulfonated phthalocyanine; SYNTHETIC PHENOLIC ANTIOXIDANTS; EDIBLE OILS; BUTYLATED HYDROXYANISOLE; VOLTAMMETRIC DETERMINATION; METHOD VALIDATION; SENSOR; FOOD; HYDROXYTOLUENE; OXIDE; TBHQ;
D O I
10.1007/s10800-024-02093-0
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
We present an approach on the electrodeposition of gold nanoparticles (AuNPs) on a carbon fiber microelectrode (CFME) followed by deposition of nickel(II) tetrasulfonated phthalocyanine (p-NiTSPc) film by electropolymerization to form CFME-AuNPs/p-NiTSPc, for the sensitive determination of butylhydroxyanisole (BHA) using cyclic voltammetry (CV) and differential pulse voltammetry (DPV). Atomic force microscopy (AFM), scanning electron microscopy (SEM), and energy-dispersive X-ray spectroscopy (EDX) were used to characterize the topography, morphology, and elemental composition of CFME, CFME-AuNPs, CFME-p-NiTSPc, and CFME-AuNPs/p-NiTSPc, respectively. Additionally, the electrochemical impedance spectroscopy (EIS) technique was employed to evaluate the charge-transfer rate of the tested sensors. To establish the optimal conditions for the electroanalysis of BHA, various parameters were investigated, including the potential scan rate, pH, and electrolysis potential. CFME-AuNPs/p-NiTSPc demonstrated the highest BHA signal, corresponding to the highest active surface area of 0.025 cm2, compared to CFME-p-NiTSPc (0.024 cm2), CFME-AuNPs (0.022 cm2), and CFME (0.021 cm2). In a phosphate buffer solution (PBS, 0.1 M; pH 3), a good linear relationship (R2 = 0.998) was observed between peak current intensities and BHA concentrations in the range of 10-80 mu M, resulting to a detection limit (LOD) of 3.60 mu M (S/N = 3) and a quantification limit (LOQ) of 12 mu M (S/N = 10). The analytical HPLC technique was also tested for BHA determination within the concentration range of 5.55-55.48 mu M and the obtained LOD was calculated to be 4.41 mu M. The potential interference of certain species that could affect the BHA oxidation signal was also evaluated, followed by the application of CFME-AuNPs/p-NiTSPc in real water and Mitosyl ointment samples. The recovery values of BHA were acceptable, ranging from 96 to 99% and demonstrating that the developed sensor is highly sensitive and effective for detecting trace amounts of BHA.
引用
收藏
页码:2121 / 2134
页数:14
相关论文
共 50 条
  • [21] Highly selective electrochemical method for the detection of serotonin at carbon fiber microelectrode modified with gold nanoflowers and overoxidized polypyrrole
    Song, Jiajia
    Wang, Lifen
    Qi, Hetong
    Qi, Honglan
    Zhang, Chengxiao
    CHINESE CHEMICAL LETTERS, 2019, 30 (09) : 1643 - 1646
  • [22] Simultaneous determination of aesculin and aesculetin and their interactions with DNA using carbon fiber microelectrode modified by Pt-Au bimetallic nanoparticles
    Bao, Changhao
    Shi, Min
    Ma, Wenwen
    Li, Jun
    Huang, Xianju
    Cheng, Han
    ANALYTICA CHIMICA ACTA, 2022, 1202
  • [23] Electrochemical sensor for nitroaromatic type energetic materials using gold nanoparticles/poly(o-phenylenediamine-aniline) film modified glassy carbon electrode
    Saglam, Sener
    Uzer, Aysem
    Tekdemir, Yasemin
    Ercag, Erol
    Apak, Resat
    TALANTA, 2015, 139 : 181 - 188
  • [24] Electrochemical sensor for the determination of ketoconazole based on gold nanoparticles modified carbon paste electrode
    Saleh, Tawfik A.
    AlAqad, Khaled M. M.
    Rahim, Abdur
    JOURNAL OF MOLECULAR LIQUIDS, 2018, 256 : 39 - 48
  • [25] Gold nanoparticles-carbon nanotubes modified sensor for electrochemical determination of organophosphate pesticides
    Yan Zhang
    Tian-Fang Kang
    Yi-Wen Wan
    Shui-Yuan Chen
    Microchimica Acta, 2009, 165 : 307 - 311
  • [26] Gold nanoparticles-carbon nanotubes modified sensor for electrochemical determination of organophosphate pesticides
    Zhang, Yan
    Kang, Tian-Fang
    Wan, Yi-Wen
    Chen, Shui-Yuan
    MICROCHIMICA ACTA, 2009, 165 (3-4) : 307 - 311
  • [27] Development of electrochemical sensors for the determination of selenium using gold nanoparticles modified electrodes
    Segura, Rodrigo
    Pizarro, Jaime
    Diaz, Karina
    Placencio, Alan
    Godoy, Fernando
    Pino, Eduardo
    Recio, Francisco
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 220 : 263 - 269
  • [28] Electrochemical determination of human hemoglobin by using ferrocene carboxylic acid modified carbon powder microelectrode
    Chen, M
    Stöcklein, W
    Scheller, FW
    Wollenberger, U
    ANALYTICAL LETTERS, 2003, 36 (09) : 2049 - 2059
  • [29] Electrochemical Determination of Tetracycline Using Molecularly Imprinted Polymer Modified Carbon Nanotube-Gold Nanoparticles Electrode
    Wang, Hongtao
    Zhao, Huimin
    Quan, Xie
    Chen, Shuo
    ELECTROANALYSIS, 2011, 23 (08) : 1863 - 1869
  • [30] Electrochemical Morphine Sensing Using Gold Nanoparticles Modified Carbon Paste Electrode
    Atta, Nada F.
    Galal, Ahmed
    Azab, Shereen M.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2011, 6 (10): : 5066 - 5081