A local POE-based self-calibration method using position and distance constraints for collaborative robots

被引:10
作者
He, Jianhui [1 ,2 ]
Gu, Lefeng [3 ]
Yang, Guilin [1 ,2 ]
Feng, Yiyang [1 ,2 ]
Chen, Silu [1 ,2 ]
Fang, Zaojun [1 ,2 ]
机构
[1] Chinese Acad Sci, Ningbo Inst Mat Technol & Engn, Zhejiang Key Lab Robot & Intelligent Mfg Equipment, Ningbo 315201, Zhejiang, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[3] Tsinghua Univ, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
Collaborative robot; Local POE formula; Kinematic error model; Self-calibration method; Position and distance constraints; KINEMATIC CALIBRATION; PRODUCT; MODEL;
D O I
10.1016/j.rcim.2023.102685
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Collaborative robots are designed to not only work alongside humans but also adapt to new tasks quickly. To improve their absolute accuracy, self-calibration methods utilizing portable measurement devices are cost-effective solutions. Based on the local frame representation of the Product-of-Exponential (POE) formula, a new modular kinematic error model is derived for collaborative robots, in which all geometric errors in a joint-link assembly, i.e., a dyad, are lumped into a local rigid body motion applied to its nominal joint axis. Its major advantage over the conventional local POE-based kinematic error model is that all columns in the error transformation Jacobian matrix are functions of joint displacements, which is critical to formulate singularity -free self-calibration models based on geometric constraints. A portable and cost-effective self-calibration device with both position and distance constraints is proposed for collaborative robots, which can readily collect a wide range of constraint errors by drag teaching within a collaborative robot's workspace. Additionally, a two-step self-calibration method is established for both the robot arm and its base calibration. Its effectiveness and robustness are validated through simulations and experiments. The experimental results on Aubo i5 show that its average position error is significantly reduced from 4.11 mm to 0.36 mm after calibration.
引用
收藏
页数:13
相关论文
共 30 条
[1]   Design of a Parallel Robot for Needle-Based Interventions on Small Animals [J].
Bebek, Ozkan ;
Hwang, Myun Joong ;
Cavusoglu, M. Cenk .
IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2013, 18 (01) :62-73
[2]  
Besnard S, 2000, ADVANCES IN ROBOT KINEMATICS, P61
[3]  
Brockett R. W., 2005, MATH THEORY NETWORKS, P120
[4]   Determination of the Identifiable Parameters in Robot Calibration Based on the POE Formula [J].
Chen, Genliang ;
Wang, Hao ;
Lin, Zhongqin .
IEEE TRANSACTIONS ON ROBOTICS, 2014, 30 (05) :1066-1077
[5]  
Chen IM, 1997, J ROBOTIC SYST, V14, P807, DOI 10.1002/(SICI)1097-4563(199711)14:11<807::AID-ROB4>3.3.CO
[6]  
2-3
[7]   Local POE model for robot kinematic calibration [J].
Chen, IM ;
Yang, GL ;
Tan, CT ;
Yeo, SH .
MECHANISM AND MACHINE THEORY, 2001, 36 (11-12) :1215-1239
[8]  
Everett L. J., 1987, Proceedings of the 1987 IEEE International Conference on Robotics and Automation (Cat. No.87CH2413-3), P183
[9]   Self-Calibration of an Industrial Robot Using a Novel Affordable 3D Measuring Device [J].
Gaudreault, Martin ;
Joubair, Ahmed ;
Bonev, Ilian .
SENSORS, 2018, 18 (10)
[10]   A Two-Step Self-calibration Method with Portable Measurement Devices for Industrial Robots Based on POE Formula [J].
Gu, Lefeng ;
Yang, Guilin ;
Fang, Zaojun ;
Shen, Wenjun ;
Zheng, Tianjiang ;
Chen, Chinyin ;
Zhang, Chi .