Elastic and viscous bumpers for seismic mitigation of base-isolated liquid storage tanks in near-fault zones

被引:4
作者
Bagheri, Saman [1 ]
Farajian, Mostafa [2 ]
机构
[1] Univ Tabriz, Fac Civil Engn, 29 Bahman Blvd, Tabriz 5166616471, Iran
[2] Western Sydney Univ, Sch Engn, Ctr Infrastruct Engn, Penrith, NSW, Australia
关键词
base isolation; near-fault earthquakes; liquid storage tanks; collision; bumper; ISOLATED BRIDGES;
D O I
10.1177/10775463221116493
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The use of friction pendulum system (FPS) as a base isolation system is one of the efficient and reliable techniques for seismic response reduction of liquid storage tanks. However, recent studies have shown that the FPS may experience substantial displacements under pulse-like near-fault earthquakes, which could lead to the collision of its articulated slider against the retainer ring. This internal impact in the FPS can make the isolation system less effective or even damaged. The best solution to this problem is to provide an appropriate displacement capacity of the FPS bearing to accommodate the resulting movements. However, due to any practical limitation or under extreme ground motions, the base displacement may exceed the displacement capacity provided and an internal impact may occur. This paper proposes and investigates the use of elastic and viscous bumpers in FPS-isolated tanks subjected to near-fault earthquakes to limit excessive bearing displacements and to prevent direct impact with the retainer. The material properties of the bumpers and their initial gap distance are used as variable parameters in the nonlinear time-history analyses of selected isolated tanks with different aspect ratios. The results, while showing the advantages of viscous bumpers over elastic ones, indicate the effectiveness of both shock absorbers in isolated tanks that are subject to large displacement demands. Based on the results of the parametric study, design recommendations are given for the use of such bumpers in FPS-isolated tanks.
引用
收藏
页码:4334 / 4343
页数:10
相关论文
共 20 条
[1]   Parametric analysis of liquid storage tanks base isolated by curved surface sliding bearings [J].
Abali, Emre ;
Uckan, Eren .
SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2010, 30 (1-2) :21-31
[2]   Influence of the characteristics of isolation and mitigation devices on the response of single-degree-of-freedom vibro-impact systems with two-sided bumpers and gaps via shaking table tests [J].
Andreaus, Ugo ;
De Angelis, Maurizio .
STRUCTURAL CONTROL & HEALTH MONITORING, 2020, 27 (05)
[3]  
API (American Petroleum Institute Standards), 2007, Welded Tanks for Oil Storage
[4]   Lateral Impact Resilient double concave Friction Pendulum (LIR-DCFP) bearing: Formulation, parametric study of the slider and three-dimensional numerical example [J].
Auad, Gaspar ;
Almazan, Jose L. .
ENGINEERING STRUCTURES, 2021, 233
[5]  
Bagheri S., 2005, P 10 INT C CIV STRUC
[6]   The effects of input earthquake characteristics on the nonlinear dynamic behavior of FPS isolated liquid storage tanks [J].
Bagheri, Saman ;
Farajian, Mostafa .
JOURNAL OF VIBRATION AND CONTROL, 2018, 24 (07) :1264-1282
[7]   SHAKE TABLE TEST OF CYLINDRICAL WATER TANKS IN BASE-ISOLATED STRUCTURES [J].
CHALHOUB, MS ;
KELLY, JM .
JOURNAL OF ENGINEERING MECHANICS-ASCE, 1990, 116 (07) :1451-1472
[8]   Experimental study on the seismic response of liquid storage tanks with Sliding Concave Bearings [J].
Compagnoni, Maria E. ;
Curadelli, Oscar ;
Ambrosini, Daniel .
JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 2018, 55 :1-9
[9]   Performance of seismic-isolated bridges with and without elastic-gap devices in near-fault zones [J].
Dicleli, Murat .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2008, 37 (06) :935-954
[10]   Supplemental elastic stiffness to reduce isolator displacements for seismic-isolated bridges in near-fault zones [J].
Dicleli, Murat .
ENGINEERING STRUCTURES, 2007, 29 (05) :763-775