Noninvasive Estimation of Blood Pressure in HeartMate 3 Patients

被引:0
作者
Pinsino, Alberto [1 ,2 ]
Gaudig, Antonia [3 ]
Castagna, Francesco [2 ,4 ]
Mondellini, Giulio M. [2 ,5 ]
Mcdonnell, Barry J. [6 ]
Stoehr, Eric J. [2 ,7 ]
Cockcroft, John [6 ]
Kormos, Robert L. [8 ]
Sayer, Gabriel T. [2 ]
Uriel, Nir [2 ]
Naka, Yoshifumi [9 ]
Takeda, Koji [10 ]
Yuzefpolskaya, Melana [2 ]
Colombo, Paolo C. [2 ,11 ]
机构
[1] Montefiore Med Ctr, Div Crit Care Med, Bronx, NY USA
[2] Columbia Univ, Irving Med Ctr, Div Cardiol, New York, NY USA
[3] Westfal Wilhelms Univ Munster, Munster, Germany
[4] Montefiore Med Ctr, Div Cardiol, Bronx, NY USA
[5] Univ Milan, Milan, Italy
[6] Cardiff Metropolitan Univ, Sch Sport & Hlth Sci, Cardiff, Wales
[7] Leibniz Univ Hannover, Inst Sports Sci, COR HELIX Cardiovasc Regulat & Human Exercise Lab, Hannover, Germany
[8] Med Affairs, Austin, TX USA
[9] Weill Cornell Med, Div Heart Failure Heart Transplantat & Mech Circul, New York, NY USA
[10] Columbia Univ, Div Cardiothorac Surg, Irving Med Ctr, New York, NY USA
[11] Columbia Univ, Div Cardiol, Irving Med Ctr, 622 West 168th St,PH 12-134, New York, NY 10032 USA
关键词
blood pressure; left ventricular assist device; Doppler; automated blood pressure monitor;
D O I
10.1097/MAT.0000000000002012
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Blood pressure (BP) measurement is challenging among patients with continuous-flow left ventricular assist device (CF-LVAD) due to reduced pulse pressure (PP). Although Doppler opening BP (DOBP) is uniformly obtainable and provides an accurate measure of systolic BP (SBP), it routinely overestimates mean arterial pressure (MAP), particularly among CF-LVAD patients with higher PP.1,2 The success rate of traditional cuff-based automated BP (ABP) monitors ranges from 50% to 80%, and is highly dependent on PP.1–3 The HeartMate 3 (HM3, Abbott Labs) is the latest generation CF-LVAD with an improved pump design that resulted in significant reduction in mortality and hemocompatibility-related adverse events,4 and, eventually, in a monopoly of the market. The HM3 features an artificial pulse which occurs asynchronously from the native. © 2024 Lippincott Williams and Wilkins. All rights reserved.
引用
收藏
页码:e18 / e20
页数:3
相关论文
共 8 条
  • [1] Physiology and Clinical Utility of HeartMate Pump Parameters
    Belkin, Mark N.
    Kagan, Viktoriya
    Labuhn, Colleen
    Pinney, Sean P.
    Grinstein, Jonathan
    [J]. JOURNAL OF CARDIAC FAILURE, 2022, 28 (05) : 845 - 862
  • [2] Ideal methodology to assess systemic blood pressure in patients with continuous-flow left ventricular assist devices
    Bennett, Mosi K.
    Roberts, Celine A.
    Dordunoo, Dzifa
    Shah, Ashish
    Russell, Stuart D.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2010, 29 (05) : 593 - 594
  • [3] The Unique Blood Pressures and Pulsatility of LVAD Patients: Current Challenges and Future Opportunities
    Castagna, Francesco
    Stohr, Eric J.
    Pinsino, Alberto
    Cockcroft, John R.
    Willey, Joshua
    Garan, A. Reshad
    Topkara, Veli K.
    Colombo, Paolo C.
    Yuzefpolskaya, Melana
    McDonnell, Barry J.
    [J]. CURRENT HYPERTENSION REPORTS, 2017, 19 (10)
  • [4] Non-invasive measurement of peripheral, central and 24-hour blood pressure in patients with continuous-flow left ventricular assist device
    Castagna, Francesco
    McDonnell, Barry J.
    Stohr, Eric J.
    Yuzefpolskaya, Melana
    Trinh, Pauline N.
    Topkara, Veli K.
    Garan, A. Reshad
    Flannery, Margaret A.
    Takeda, Koji
    Takayama, Hiroo
    Naka, Yoshifumi
    Demmer, Ryan T.
    Wassertheurer, Siegfried
    Cockcroft, John
    Colombo, Paolo C.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2017, 36 (06) : 694 - 697
  • [5] Variability in Blood Pressure Assessment in Patients Supported with the HeartMate 3TM
    Cowger, Jennifer A.
    Estep, Jerry D.
    Rinde-Hoffman, Debbie A.
    Givertz, Michael M.
    Anderson, Allen S.
    Jacoby, Daniel
    Chen, Leway
    Brieke, Andreas
    Mahr, Claudius
    Hall, Shelley
    Ewald, Gregory A.
    Dirckx, Nick
    Baker, Andrew T.
    Pinney, Sean P.
    [J]. ASAIO JOURNAL, 2022, 68 (03) : 374 - 383
  • [6] Lanier GM., 2013, Circ Heart Fail, V112, P000186
  • [7] A Fully Magnetically Levitated Left Ventricular Assist Device - Final Report
    Mehra, M. R.
    Uriel, N.
    Naka, Y.
    Cleveland, J. C., Jr.
    Yuzefpolskaya, M.
    Salerno, C. T.
    Walsh, M. N.
    Milano, C. A.
    Patel, C. B.
    Hutchins, S. W.
    Ransom, J.
    Ewald, G. A.
    Itoh, A.
    Raval, N. Y.
    Silvestry, S. C.
    Cogswell, R.
    John, R.
    Bhimaraj, A.
    Bruckner, B. A.
    Lowes, B. D.
    Um, J. Y.
    Jeevanandam, V.
    Sayer, G.
    Mangi, A. A.
    Molina, E. J.
    Sheikh, F.
    Aaronson, K.
    Pagani, F. D.
    Cotts, W. G.
    Tatooles, A. J.
    Babu, A.
    Chomsky, D.
    Katz, J. N.
    Tessmann, P. B.
    Dean, D.
    Krishnamoorthy, A.
    Chuang, J.
    Topuria, I.
    Sood, P.
    Goldstein, D. J.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2019, 380 (17) : 1618 - 1627
  • [8] Noninvasive Blood Pressure Monitor Designed for Patients With Heart Failure Supported with Continuous-Flow Left Ventricular Assist Devices
    Sajgalik, Pavol
    Kremen, Vaclav
    Fabian, Vratislav
    Maltais, Simon
    Stulak, John M.
    Kushwaha, Sudhir S.
    Joyce, Lyle D.
    Schirger, John A.
    Johnson, Bruce D.
    [J]. ASAIO JOURNAL, 2019, 65 (02) : 127 - 133