Evaluation of biometric indicators of anterior segment parameters after ICL implantation by swept-source optical coherence tomography

被引:5
作者
Tang, Chuhao [1 ]
Sun, Tong [1 ]
Sun, Zhengze [1 ]
Duan, Hongyu [1 ]
Liu, Yilin [1 ]
Zhao, Lu [1 ]
Li, Wenlong [1 ]
Bian, Linbo [1 ]
Qi, Hong [1 ]
机构
[1] Peking Univ Third Hosp, Dept Ophthalmol, Beijing Key Lab Restorat Damaged Ocular Nerve 9, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
Implantable collamer lens implantation surgery; Myopia; Optical coherence tomography; Vault; Iridotrabecular contact; PRIMARY ANGLE-CLOSURE; COLLAMER LENS ICL; HIGH MYOPIA; CONTACT; MODERATE; INDEX;
D O I
10.1186/s12886-023-02942-0
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BackgroundTo evaluate anterior segment structural alterations after implantable collamer lens (ICL) implantation in myopic patients using swept-source quantitative optical coherence tomography (SS-OCT).MethodsThis prospective study included 47 eyes in 24 patients with preoperative spherical equivalent >= -3.00 D. Patients underwent ICL implantation at Department of Ophthalmology, Peking University Third Hospital, from May 2021 to December 2022. SS-OCT was used to measure anterior chamber width (ACW), angle opening distance (AOD), angle recess area (ARA), trabecular-iris area (TISA), trabecular-iris angle (TIA), iridotrabecular contact (ITC) area, and ITC Index before ICL implantation surgery and at 1 month follow-up. The correlations among the ITC index, vault, and angle parameters were analysed. Receiver operating characteristic (ROC) analysis was used to explore the ability of the vault to identify eyes with suspected angle-closure.ResultsAt one month following ICL implantation, the ITC area was 0.396 +/- 0.37 mm(2), and the ITC index is 8.143 +/- 5.439%. All angle parameters, except ACW, showed a statistically significant reduction on SS-OCT (P < 0.05). Mean AOD500, AOD750, ARA500, ARA750, TISA500, TISA750, TIA500, and TIA750 values at one month postoperatively decreased by 60.0%, 60.4%, 58.1%, 59.2%, 57.3%, 58.7%, 48.8%, and 50.7%, respectively. The vault was positively correlated with the ITC index and percent change in anterior chamber angle parameters. A vault of > 0.659 mm was found to be optimal for angle-closure suspect with a sensitivity of 85.2% and a specificity of 53.9%.ConclusionsAnterior chamber angle parameters decreased one month after ICL implantation, and their percentage changes and ITC index correlated with the vault. When the vault is larger than 0.659 mm, it is necessary to be alert to possible closed angle suspicion.
引用
收藏
页数:10
相关论文
共 31 条
  • [1] Gonioscopic changes after implantation of a posterior chamber lens in phakic myopic eyes
    Abela-Formanek, C
    Kruger, AJ
    Dejaco-Ruhswurm, I
    Pieh, S
    Skorpik, C
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (12) : 1919 - 1925
  • [2] Interocular biometric parameters comparison measured with swept-source technology
    Albarran-Diego, Cesar
    Poyales, Francisco
    Lopez-Artero, Esther
    Garzon, Nuria
    Garcia-Montero, Maria
    [J]. INTERNATIONAL OPHTHALMOLOGY, 2022, 42 (01) : 239 - 251
  • [3] Angmo Dewang, 2016, Oman J Ophthalmol, V9, P3, DOI 10.4103/0974-620X.176093
  • [4] Collamer intraocular contact lens to correct high myopia
    Assetto, V
    Benedetti, S
    Pesando, P
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1996, 22 (05) : 551 - 556
  • [5] Assessment of Circumferential Angle-Closure by the IriseTrabecular Contact Index with Swept-Source Optical Coherence Tomography
    Baskaran, Mani
    Ho, Sue-Wei
    Tun, Tin A.
    How, Alicia C.
    Perera, Shamira A.
    Friedman, David S.
    Aung, Tin
    [J]. OPHTHALMOLOGY, 2013, 120 (11) : 2226 - 2231
  • [6] Causes of blindness and vision impairment in, 2020, LANCET GLOB HEALTH, V9, pe144, DOI [10.1016/S2214-109X(20)30489-7, DOI 10.1016/S2214-109X(20)30489-7]
  • [7] A Rare Case of Pupillary Block Glaucoma Following CentraFLOW Implantable Collamer Lens Surgery
    Grover, Isha G.
    Senthil, Sirisha
    Murthy, Somasheila
    Reddy, Jagadesh C.
    [J]. JOURNAL OF GLAUCOMA, 2017, 26 (08) : 694 - 696
  • [8] Quantification of Iridotrabecular Contact in Primary Angle-Closure Disease
    Gupta, Barkha
    Angmo, Dewang
    Yadav, Suresh
    Dada, Tanuj
    Gupta, Viney
    Sihota, Ramanjit
    [J]. JOURNAL OF GLAUCOMA, 2020, 29 (08) : 681 - 688
  • [9] Swept source optical coherence tomography measurement of the iris-trabecular contact (ITC) index: a new parameter for angle closure
    Ho, Sue-Wei
    Baskaran, Mani
    Zheng, Ce
    Tun, Tin A.
    Perera, Shamira A.
    Narayanaswamy, Arun K.
    Friedman, David S.
    Aung, Tin
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 251 (04) : 1205 - 1211
  • [10] Ex-PRESS shunt implantation for intractable glaucoma with posterior chamber phakic intraocular lens: a case report
    Hu, Rongrong
    Xu, Wei
    Huang, Baishuang
    Wang, Xiaoyu
    [J]. BMC OPHTHALMOLOGY, 2021, 21 (01)