Methodological considerations for the determination of VO2max in healthy men

被引:2
作者
Succi, Pasquale J. [1 ]
Benitez, Brian [1 ]
Kwak, Minyoung [1 ]
Bergstrom, Haley C. [1 ]
机构
[1] Univ Kentucky, Dept Kinesiol & Hlth Promot, 1210 Univ Dr, Lexington, KY 40502 USA
关键词
Running; Cardiorespiratory fitness; Graded exercise test; Reliability; MAXIMAL OXYGEN-UPTAKE; VERIFICATION PHASE; O-2; UPTAKE; EXERCISE; RAMP; RELIABILITY; VO(2)MAX; CRITERIA;
D O I
10.1007/s00421-022-05033-y
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Purpose A square-wave verification bout to confirm maximal oxygen uptake ((V) over dot O-2max) from a graded exercise test (GXT) has been recommended. This study ascertained if a verification bout is necessary to determine(V) over dot O-2max in moderately trained men. Methods Ten men (24 +/- 4 years) completed familiarization and two treadmill GXTs, followed by a submaximal verification bout to determine (V) over dot O-2GXT and (V) over dot O-2verification (highest (V) over dot O-2 from each testing method). After completing the GXT, subjects rested for 5 min then performed a verification bout at 90% speed and 50% incline at termination of the GXT. The analyses included a 2-way repeated-measures ANOVA, intra-class correlation coefficients (ICC2,1), standard errors of the measurement (SEM), minimal differences (MD), and coefficients of variation (CoV). Results There was no test (test 1 vs test 2) x method (GXT vs verification) interaction (p = 0.584), or main effect for test (p = 0.320), but there was a main effect for method (p = 0.011). The (V) over dot O-2GXT (50.9 +/- 3.0 mL.kg(-1).min(-1)) was greater than (V) over dot O-2verification (46.9 +/- mL.kg(-1). min(-1)). The (V) over dot O-2GXT (ICC = 0.988, SEM = 1.0 mL.kg(-1) min(-1), MD = 2.9 mL kg(-1) min(-1), CoV = 2.03%) and (V) over dot O-2verification (ICC = 0.976, SEM = 1.0 mL.kg(-1) -min(-1), MD = 2.7 mL.kg(-1).min(-1), CoV = 2.03%) demonstrated "excellent" reliability. No subject exceeded the MD for (V) over dot O-2GXT test-retest or for (V) over dot O-2verification test-retest, but 50% of subjects had a (V) over dot O-2GXT that was greater than the (V) over dot O-2verification (> MD). Conclusion While (V) over dot O-2GXT and (V) over dot O-2verification demonstrated excellent reliability, (V) over dot O-GXT(2) from a stand-alone GXT provided higher estimates of (V) over dot O-2 and, therefore, should be considered (V) over dot O-2max. The lack of test-retest differences in (V) over dot O-2 GXT above the MD indicated that subjects achieved their highest (V) over dot O-2 ((V) over dot O-2max) from a standalone GXT. Therefore, the verification bout may not be required to confirm(V) over dot O-2max in this population.
引用
收藏
页码:191 / 199
页数:9
相关论文
共 39 条
[1]   Efficacy of constant load verification testing to confirm VO2max attainment [J].
Astorino, Todd A. ;
DeRevere, Jamie .
CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2018, 38 (04) :703-709
[2]  
Astrand P.O., 1952, Experimental Studies of Physical Working Capacity in Relation to Sex and Age
[3]   Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine [J].
Atkinson, G ;
Nevill, AM .
SPORTS MEDICINE, 1998, 26 (04) :217-238
[4]  
Beltz Nicholas M, 2016, J Sports Med (Hindawi Publ Corp), V2016, P3968393, DOI 10.1155/2016/3968393
[5]   OPTIMIZING THE EXERCISE PROTOCOL FOR CARDIOPULMONARY ASSESSMENT [J].
BUCHFUHRER, MJ ;
HANSEN, JE ;
ROBINSON, TE ;
SUE, DY ;
WASSERMAN, K ;
WHIPP, BJ .
JOURNAL OF APPLIED PHYSIOLOGY, 1983, 55 (05) :1558-1564
[6]   RELIABILITY OF NEUROMUSCULAR MEASUREMENTS DURING EXPLOSIVE ISOMETRIC CONTRACTIONS, WITH SPECIAL REFERENCE TO ELECTROMYOGRAPHY NORMALIZATION TECHNIQUES [J].
Buckthorpe, Matthew W. ;
Hannah, Ricci ;
Pain, Matthew T. G. ;
Folland, Jonathan P. .
MUSCLE & NERVE, 2012, 46 (04) :566-576
[7]   \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$ \dot{V}_{{{\text{O}}_{2} { \max }}} $$\end{document} is not altered by self-pacing during incremental exercise [J].
Weerapong Chidnok ;
Fred J. DiMenna ;
Stephen J. Bailey ;
Mark Burnley ;
Daryl P. Wilkerson ;
Anni Vanhatalo ;
Andrew M. Jones .
European Journal of Applied Physiology, 2013, 113 (2) :529-539
[8]   Sociodemographic, laboratory, image data and predictors of gravity risk in patients with COVID-19 [J].
Costa, Victor de Oliveira ;
Nicolini, Eveline Montessi ;
da Costa, Bruna Malaquias Arguelles ;
Ferreira, Victor Hugo Perches ;
Tonisi, Ana Julia Rodrigues ;
Machado, Nathalia Munck ;
Moura, Marcos de Assis ;
Montessi, Jorge ;
de Castro Ferreira, Lincoln Eduardo Villela Vieira ;
Campos, Rogerio Leal ;
Costa, Patricia Moreira ;
Campos, Maria Antonia .
PLOS ONE, 2021, 16 (08)
[9]  
Czuba M., 2010, STUDIES PHYS CULTURE, V17, P123
[10]   Suitability of Verification Testing to Confirm Attainment of VO2max in Middle-Aged and Older Adults [J].
Dalleck, Lance C. ;
Astorino, Todd A. ;
Erickson, Rachel M. ;
McCarthy, Caitlin M. ;
Beadell, Alyssa A. ;
Botten, Brigette H. .
RESEARCH IN SPORTS MEDICINE, 2012, 20 (02) :118-128