Variation in cartilage T2 and T2*mapping of the wrist: a comparison between 3-and 7-T MRI

被引:5
|
作者
Heiss, Rafael [1 ]
Weber, Marc-Andre [2 ]
Balbach, Eva L. [1 ]
Hinsen, Maximilian [1 ]
Geissler, Frederik [1 ]
Nagel, Armin M. [1 ,3 ]
Ladd, Mark E. [3 ,4 ,5 ]
Arkudas, Andreas [6 ,7 ]
Horch, Raymund E. [6 ,7 ]
Gall, Christine [8 ]
Uder, Michael [1 ]
Roemer, Frank W. [1 ,9 ]
机构
[1] Univ Hosp Erlangen, Friedrich Alexander Univ Erlangen Nurnberg FAU, Dept Radiol, Maximilianspl 3, D-91054 Erlangen, Germany
[2] Univ Med Ctr Rostock, Inst Diagnost & Intervent Radiol, Pediat Radiol & Neuroradiol, Schillingallee 35, D-18057 Rostock, Germany
[3] German Canc Res Ctr, Med Phys Radiol, Neuenheimer Feld 280, D-69120 Heidelberg, Germany
[4] Heidelberg Univ, Fac Med, Neuenheimer Feld 226, D-69120 Heidelberg, Germany
[5] Heidelberg Univ, Fac Phys & Astron, Neuenheimer Feld 226, D-69120 Heidelberg, Germany
[6] Friedrich Alexander Univ Erlangen Nurnberg FAU, Univ Hosp Erlangen, Dept Plast & Hand Surg, Krankenhausstr 12, D-91054 Erlangen, Germany
[7] Friedrich Alexander Univ Erlangen Nurnberg FAU, Univ Hosp Erlangen, Lab Tissue Engn & Regenerat Med, Krankenhausstr 12, D-91054 Erlangen, Germany
[8] Friedrich Alexander Univ Erlangen Nurnberg FAU, Inst Med Informat Biometry & Epidemiol, Waldstr 6, D-91054 Erlangen, Germany
[9] Boston Univ, Sch Med, 72 E Concord St, Boston, MA 02118 USA
关键词
Cartilage (articular); Image processing (computer-assisted); Magnetic resonance imaging; Triangular fibrocartilage; Wrist joint; HUMAN ARTICULAR-CARTILAGE; GADOLINIUM-ENHANCED MRI; RELAXATION-TIME; MAGNETIC-RESONANCE; COIL; FIELD; OSTEOARTHRITIS; QUANTITATION; SEQUENCE;
D O I
10.1186/s41747-023-00394-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundTo analyze regional variations in T2 and T2* relaxation times in wrist joint cartilage and the triangular fibrocartilage complex (TFCC) at 3 and 7 T and to compare values between field strengths.MethodsTwenty-five healthy controls and 25 patients with chronic wrist pain were examined at 3 and 7 T on the same day using T2- and T2*-weighted sequences. Six different regions of interest (ROIs) were evaluated for cartilage and 3 ROIs were evaluated at the TFCC based on manual segmentation. Paired t-tests were used to compare T2 and T2* values between field strengths and between different ROIs. Spearman's rank correlation was calculated to assess correlations between T2 and T2* time values at 3 and 7 T.ResultsT2 and T2* time values of the cartilage differed significantly between 3 and 7 T for all ROIs (p <= 0.045), with one exception: at the distal lunate, no significant differences in T2 values were observed between field strengths. T2* values differed significantly between 3 and 7 T for all ROIs of the TFCC (p <= 0.001). Spearman's rank correlation between 3 and 7 T ranged from 0.03 to 0.62 for T2 values and from 0.01 to 0.48 for T2* values. T2 and T2* values for cartilage varied across anatomic locations in healthy controls at both 3 and 7 T.ConclusionQuantitative results of T2 and T2* mapping at the wrist differ between field strengths, with poor correlation between 3 and 7 T. Local variations in cartilage T2 and T2* values are observed in healthy individuals.Relevance statementT2 and T2* mapping are feasible for compositional imaging of the TFCC and the cartilage at the wrist at both 3 and 7 T, but the clinical interpretation remains challenging due to differences between field strengths and variations between anatomic locations.Key points center dot Field strength and anatomic locations influence T2 and T2* values at the wrist.center dot T2 and T2* values have a poor correlation between 3 and 7 T.center dot Local reference values are needed for each anatomic location for reliable interpretation.Key points center dot Field strength and anatomic locations influence T2 and T2* values at the wrist.center dot T2 and T2* values have a poor correlation between 3 and 7 T.center dot Local reference values are needed for each anatomic location for reliable interpretation.Key points center dot Field strength and anatomic locations influence T2 and T2* values at the wrist.center dot T2 and T2* values have a poor correlation between 3 and 7 T.center dot Local reference values are needed for each anatomic location for reliable interpretation.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] 7 Tesla quantitative hip MRI: a comparison between TESS and CPMG for T2 mapping
    Oliver Kraff
    Andrea Lazik-Palm
    Rahel Heule
    Jens M. Theysohn
    Oliver Bieri
    Harald H. Quick
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2016, 29 : 503 - 512
  • [22] T2 mapping and T2*imaging in heart failure
    Lota, A. S.
    Gatehouse, P. D.
    Mohiaddin, R. H.
    HEART FAILURE REVIEWS, 2017, 22 (04) : 431 - 440
  • [23] 7 Tesla quantitative hip MRI: a comparison between TESS and CPMG for T2 mapping
    Kraff, Oliver
    Lazik-Palm, Andrea
    Heule, Rahel
    Theysohn, Jens M.
    Bieri, Oliver
    Quick, Harald H.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2016, 29 (03) : 503 - 512
  • [24] T2 MRI Mapping of Knee Cartilage in Professional Ballet Dancers
    Kazci, Omer
    Yigit, Hasan
    Kosar, Pinar
    MEDICAL PROBLEMS OF PERFORMING ARTISTS, 2020, 35 (04) : 221 - 226
  • [25] Cartilage MRI T2 relaxation time mapping: Overview and applications
    Mosher, TJ
    Dardzinski, BJ
    SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2004, 8 (04) : 355 - 368
  • [26] T2 mapping and T2* imaging in heart failure
    A.S. Lota
    P.D. Gatehouse
    R.H. Mohiaddin
    Heart Failure Reviews, 2017, 22 : 431 - 440
  • [27] Comparison of MRI T1, T2, and T2*mapping with histology for assessment of intervertebral disc degeneration in an ovine model
    Bouhsina, Nora
    Decante, Cyrille
    Hardel, Jean-Baptiste
    Rouleau, Dominique
    Abadie, Jerome
    Hamel, Antoine
    Le Visage, Catherine
    Lesoeur, Julie
    Guicheux, Jerome
    Clouet, Johann
    Fusellier, Marion
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [28] Comparison of MRI T1, T2, and T2* mapping with histology for assessment of intervertebral disc degeneration in an ovine model
    Nora Bouhsina
    Cyrille Decante
    Jean-Baptiste Hardel
    Dominique Rouleau
    Jérôme Abadie
    Antoine Hamel
    Catherine Le Visage
    Julie Lesoeur
    Jérôme Guicheux
    Johann Clouet
    Marion Fusellier
    Scientific Reports, 12
  • [29] T2 and T1, MRI in articular cartilage systems
    Menezes, NM
    Gray, ML
    Hartke, JR
    Burstein, D
    MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (03) : 503 - 509
  • [30] Magnetization transfer contrast and T2 mapping in the evaluation of cartilage repair tissue with 3T MRI
    Welsch, Goetz H.
    Trattnig, Siegfried
    Scheffler, Klaus
    Szomonanyi, Pavol
    Quirbach, Sebastian
    Marlovits, Stefan
    Domayer, Stephan
    Bieri, Oliver
    Mamisch, Tallal C.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (04) : 979 - 986