FRP-concrete-steel tubular columns with a large inner void under lateral impact loading: Experimental study and finite-element modelling

被引:16
|
作者
Zhang, Bing [1 ,2 ]
Lin, Shuhong [1 ]
Zhang, Sumei [1 ,2 ]
Jiang, Yuexin [3 ]
Lai, Congcong [4 ]
Fu, Xizhe [1 ]
机构
[1] Harbin Inst Technol Shenzhen, Sch Civil & Environm Engn, Shenzhen 518055, Peoples R China
[2] Harbin Inst Technol, Shenzhen Key Lab Intelligent Struct Syst Civil Eng, Shenzhen 518055, Peoples R China
[3] Suzhou Univ Sci & Technol, Sch Civil Engn, Suzhou 215011, Peoples R China
[4] Nanjing Tech Univ, Coll Civil Engn, Nanjing 211816, Peoples R China
来源
JOURNAL OF BUILDING ENGINEERING | 2023年 / 80卷
基金
中国国家自然科学基金;
关键词
FRP; Tubular columns; Large inner void; Impact loading; FE modelling; CIRCULAR RC COLUMNS; BEHAVIOR; BRIDGE;
D O I
10.1016/j.jobe.2023.108006
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
By combining two concentrically placed tubes (i.e., an FRP tube as the external sheath and a steel tube as the inner reinforcement) and a sandwiched concrete layer, FRP-concrete-steel double-skin tubular columns (DSTCs for short) are an attractive type of hollow-core columns suitable for bridge piers working in humid and corrosive environments. The very limited experimental studies on DSTCs under impact loading had one or two of the following limitations: (1) the void ratio phi was far smaller than the size with practical engineering value; (2) the column diameter Dc was too small compared with the section size used in real engineering. To supplement the existing research, DSTCs with a large inner void and a practical large column diameter (i.e., phi = 0.73 and 0.82; Dc = 300 mm) were experimentally investigated subjected to lateral impact loading, with particular research attentions on parameters including the impact velocity, the boundary conditions, as well as the void ratio of the DSTC specimen. Test results indicated that: (1) the failure mechanism was primarily controlled by the boundary condition; a bending-dominant failure mode was observed for the DSTC specimen with the top end free and the bottom end fixed; in contrast, a small global lateral displacement and severe localized dent deformation was observed for the DSTC specimen with the top end simply-supported and the bottom end fixed; (2) the peak impact force, the impact duration as well as the residual lateral displacement had a positive correlation trend with the impact velocity; (3) a DSTC specimen with a larger void ratio had a lower peak impact force and a smaller global lateral displacement. Finite element model based on ANSYS/LS-DYNA was employed to simulate DSTCs subjected to lateral impact loading, which could yield results with reasonable accuracy.
引用
收藏
页数:20
相关论文
共 50 条
  • [41] Finite element modelling of timber infilled steel tubular short columns under axial compression
    Navaratnam, Satheeskumar
    Thamboo, Julian
    Poologanathan, Keerthan
    Roy, Krishanu
    Gatheeshgar, Perampalam
    STRUCTURES, 2021, 30 : 910 - 924
  • [42] Impact Behavior of Prestressed Concrete Piles with Glass FRP Spirals: Experimental and Finite-Element Analysis
    Adegbulugbe, Olayiwola
    Jung, Sungmoon
    Kampmann, Raphael
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2024, 28 (05)
  • [43] Effect of Cross-Sectional Aspect Ratio on Rectangular FRP-Concrete-Steel Double-Skin Tubular Columns under Axial Compression
    Zhang, Bing
    Hu, Xia-Min
    Wei, Wei
    Zhang, Qian-Biao
    Zhang, Ning-Yuan
    Zhang, Yi-Jie
    ADVANCES IN POLYMER TECHNOLOGY, 2020, 2020
  • [44] Experimental behaviour of circular concrete filled steel tube columns under lateral cyclic loading
    Van Cao, Vui
    Vo, Cuong Trung
    Nguyen, Phuoc Trong
    Ashraf, Mahmud
    EARTHQUAKES AND STRUCTURES, 2021, 21 (05) : 445 - 460
  • [45] Experimental investigation into FRP-confined concrete-filled steel tubular columns under axial compression
    Ma, Lu
    Zhou, Changlin
    Zhang, Ji
    MAGAZINE OF CONCRETE RESEARCH, 2023, 75 (03) : 109 - 122
  • [46] Experimental study on the fire resistance of unprotected concrete-filled steel tubular columns under multi-loading
    Shintani, Yusuke
    Nishimura, Toshihiko
    Okazaki, Tomohito
    Kinoshita, Takuya
    Ito, Hidetoshi
    Liew, J. Y. Richard
    FIRE SAFETY JOURNAL, 2021, 120
  • [47] Finite element modelling of concrete-filled steel stub columns under axial compression
    Tao, Zhong
    Wang, Zhi-Bin
    Yu, Qing
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2013, 89 : 121 - 131
  • [48] Simplified impact force models for novel FRP-steel-concrete composite columns under axial impact loading
    Huiyu, Bai
    Daiyu, Wang
    Tao, Yu
    Changhai, Zhai
    STRUCTURES, 2023, 57
  • [49] Impact response of hybrid FRP-concrete-steel double-skin tubular bridge piers with fixed-simply supported boundary conditions: Experimental study and FE analysis
    Lin, Shuhong
    Zhang, Sumei
    Zhang, Bing
    Deng, Ran
    Peng, Yutao
    STRUCTURES, 2025, 75
  • [50] Experimental Study on FRP-Reinforced Concrete-Steel Double-Skin Tubular Columns under Eccentric Compression Loads
    Gao, Haiyang
    Wang, Lianguang
    Zhang, Ni
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2021, 25 (06)