Seismic fragility analysis of base isolation reinforced concrete structure building considering performance - a case study for Indonesia

被引:0
作者
Sulthan, Faiz [1 ]
Seki, Matsutaro [2 ]
机构
[1] Implementat Unit Bldg Mat & Struct, Directorate Gen Human Settlements, Minist Publ Works & Housing, Bandung 40622, West Java, Indonesia
[2] Bldg Res Inst 1 Tatehara, Tsukuba, Ibaraki 3050802, Japan
来源
STRUCTURAL MONITORING AND MAINTENANCE, AN INTERNATIONAL JOURNAL | 2023年 / 10卷 / 03期
关键词
fragility curve; incremental dynamic analysis; performance level evaluation; seismic isolation; DESIGN;
D O I
10.12989/smm.2023.10.3.243
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Indonesia has had seismic codes for earthquake-resistant structures designs since 1970 and has been updated five times to the latest in 2019. In updating the Indonesian seismic codes, seismic hazard maps for design also update, and there are changes to the Peak Ground Acceleration (PGA). Indonesian seismic design uses the concept of building performance levels consisting of Immediate occupancy (IO), Life Safety (LS), and Collapse Prevention (CP). Related to this performance level, cases still found that buildings were damaged more than their performance targets after the earthquake. Based on the above issues, this study aims to analyze the performance of base isolation design on existing target buildings and analyze the seismic fragility for a case study in Indonesia. The target building is a prototype design 8-story medium-rise residential building using the reinforced concrete moment frame structure. Seismic fragility analysis uses Incremental Dynamic Analysis (IDA) with Nonlinear Time History Analysis (NLTHA) and eleven selected ground motions based on soil classification, magnitude, fault distance, and earthquake source mechanism. The comparison result of IDA shows a trend of significant performance improvement, with the same performance level target and risk category, the base isolation structure can be used at 1.46-3.20 times higher PGA than the fixed base structure. Then the fragility analysis results show that the fixed base structure has a safety margin of 30% and a base isolation structure of 62.5% from the PGA design. This result is useful for assessing existing buildings or considering a new building's performance.
引用
收藏
页码:243 / 260
页数:18
相关论文
共 39 条
  • [1] [Anonymous], 2017, ASCE standard ASCE/SEI 7-16: Minimum Design Loads and Associated Criteria for Buildings and Other Structures, DOI DOI 10.1061/9780784414248
  • [2] Learning from Construction Failures due to the 2009 L'Aquila, Italy, Earthquake
    Augenti, N.
    Parisi, F.
    [J]. JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2010, 24 (06) : 536 - 555
  • [3] Benjamin J.R, 1970, Probabilty statistics and decision for civil engineers
  • [4] Bridgestone, 2017, Bridgestone seismic isolation product line-up
  • [5] Erberik Murat., 2015, Encyclopedia of Earthquake Engineering, P1, DOI DOI 10.1007/978-3-642-36197-5_387-1
  • [6] FRAGILITY CURVE OF SCHOOL BUILDING IN PADANG CITY WITH AND WITHOUT RETROFITTING DUE TO EARTHQUAKE AND TSUNAMI LOADS
    Fauzan
    Kurniawan, Ruddy
    Syahdiza, Nandaria
    Al Jauhari, Zev
    Nugraha, Dyan Adhitya M.
    [J]. INTERNATIONAL JOURNAL OF GEOMATE, 2023, 24 (101): : 102 - 109
  • [7] Gautham A, 2017, MATER TODAY-PROC, V4, P10565, DOI 10.1016/j.matpr.2017.06.421
  • [8] Seismic risk of base isolated non-ductile reinforced concrete buildings considering uncertainties and mainshock-aftershock sequences
    Han, Ruilong
    Li, Yue
    van de Lindt, John
    [J]. STRUCTURAL SAFETY, 2014, 50 : 39 - 56
  • [9] Hussain S., 2012, P 15 WORLD C EARTHQ
  • [10] Ibrahim YE., 2011, IES J A, V4, P213, DOI [10.1080/19373260.2011.609325, DOI 10.1080/19373260.2011.609325]