Range verification in heavy-ion therapy using a hadron tumour marker

被引:0
|
作者
Kasanda, E. [1 ,2 ]
Bildstein, V [1 ]
Hymers, D. [1 ,3 ]
Easter, J. [1 ]
Richard, A. L. [4 ,5 ,8 ]
Baumann, T. [4 ]
Spyrou, A. [4 ,5 ]
Hoehr, C. [6 ,7 ]
Muecher, D. [1 ,3 ,6 ]
机构
[1] Univ Guelph, Dept Phys, 50 Stone Rd E, Guelph, ON N1G 2W1, Canada
[2] Univ Bern, Lab High Energy Phys, Sidlerstr 5, CH-3012 Bern, Switzerland
[3] Univ Cologne, Inst Kernphys, Zulpicher Str 77, D-50937 Cologne, Germany
[4] Michigan State Univ, Facil Rare Isotope Beams, E Lansing, MI 48824 USA
[5] Michigan State Univ, Dept Phys & Astron, E Lansing, MI 48824 USA
[6] TRIUMF, 4004 Wesbrook Mall, Vancouver, BC V6T 2A3, Canada
[7] Univ Victoria, Dept Phys & Astron, 3800 Finnerty Rd, Victoria, BC V8P 5C2, Canada
[8] Lawrence Livermore Natl Lab, Livermore, CA USA
基金
加拿大自然科学与工程研究理事会;
关键词
hadron therapy; range verification; tumour marker; spectroscopy; PROTON; RADIOTHERAPY; FACILITY;
D O I
10.1088/1361-6560/acf557
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Anew method to estimate the range of an ion beam in a patient during heavy-ion therapy was investigated, which was previously verified for application in proton therapy. Approach. The method consists of placing a hadron tumour marker (HTM) close to the tumour. As the treatment beam impinges on the HTM, the marker undergoes nuclear reactions. When theHTMmaterial is carefully chosen, the activation results in the emission of several delayed, characteristic gamma rays, whose intensities are correlated with the remaining range inside the patient. When not just one but two reaction channels are investigated, the ratio between these two gamma ray emissions can be measured, and the ratio is independent of any beam delivery uncertainties. Main results. A proof-of-principle experiment with an 16Oion beam and Ag foils asHTMwas successfully executed. The Ag-107(O-16, (x))Sb-112 and the Ag-107(O-16, x)(114) Sb reaction channels were identified as suitable for theHTM technique. When only one gamma-ray emission is measured, the resulting range-uncertainty estimation is at the 0.5mmscale. When both channels are considered, a theoretical limit on the range uncertainty of a clinical fiducal marker was found to be +/- 290 mu m. Significance. Range uncertainty of a heavy-ion beam limits the prescribed treatment plan for cancer patients, especially the direction of the ion beam in relation to any organ at risk. An easy to implement range-verification technique which can be utilized during clinical treatment would allow treatment plans to take full advantage of the sharp falloff of the Bragg peak without the risk of depositing excessive dose into healthy tissue.
引用
收藏
页数:13
相关论文
共 43 条
  • [31] Technical Note: Experimental carbon ion range verification in inhomogeneous phantoms using prompt gammas
    Pinto, M.
    De Rydt, M.
    Dauvergne, D.
    Dedes, G.
    Freud, N.
    Krimmer, J.
    Letang, J. M.
    Ray, C.
    Testa, E.
    Testa, M.
    MEDICAL PHYSICS, 2015, 42 (05) : 2342 - 2346
  • [32] Investigation of in vivo beam range verification in carbon ion therapy using the Doppler Shift Effect of prompt gamma: A Monte Carlo simulation study
    Han, Yang
    Tang, Xiaobin
    Geng, Changran
    Shu, Diyun
    Gong, Chunhui
    Zhang, Xudong
    Wu, Shaojuan
    Zhang, Xinxin
    RADIATION PHYSICS AND CHEMISTRY, 2019, 162 : 72 - 81
  • [33] Using Track Structure Theory to Predict Heavy-Ion Cross Sections From Neutron Data and Vice Versa
    Hansen, D. L.
    Resor, S.
    Vermeire, B.
    Czajkowski, D.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2024, 71 (04) : 548 - 554
  • [34] Parton-hadron-quantum-molecular dynamics: A novel microscopic n-body transport approach for heavy-ion collisions, dynamical cluster formation, and hypernuclei production
    Aichelin, J.
    Bratkovskaya, E.
    Le Fevre, A.
    Kireyeu, V
    Kolesnikov, V
    Leifels, Y.
    Voronyuk, V.
    Coci, G.
    PHYSICAL REVIEW C, 2020, 101 (04)
  • [35] Mixed particle beam for simultaneous treatment and online range verification in carbon ion therapy: Proof-of-concept study
    Mazzucconi, Davide
    Agosteo, Stefano
    Ferrarini, Michele
    Fontana, Luigi
    Lante, Valeria
    Pullia, Marco
    Savazzi, Simone
    MEDICAL PHYSICS, 2018, 45 (11) : 5234 - 5243
  • [36] In Vivo 3-D Dose Verification Using PET/CT Images After Carbon-Ion Radiation Therapy
    Sun, Lining
    Hu, Weigang
    Lai, Songtao
    Shi, Leijun
    Chen, Junchao
    FRONTIERS IN ONCOLOGY, 2021, 11
  • [37] Development of a compact dose verification system using a fluorescent screen for carbon-ion therapy
    Hara, Yousuke
    Furukawa, Takuji
    Mizushima, Kota
    Saotome, Naoya
    Saraya, Yuichi
    Tansho, Ryohei
    Shirai, Toshiyuki
    Noda, Koji
    Takeshita, Eri
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2016, 69 (06) : 1014 - 1018
  • [38] Range and dose verification in proton therapy using proton-induced positron emitters and recurrent neural networks (RNNs)
    Liu, Chuang
    Li, Zhongxing
    Hu, Wenbin
    Xing, Lei
    Peng, Hao
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (17)
  • [39] Technical Note: Machine learning approaches for range and dose verification in proton therapy using proton-induced positron emitters
    Li, Zhongxing
    Wang, Yiang
    Yu, Yajun
    Fan, Kuanjun
    Xing, Lei
    Peng, Hao
    MEDICAL PHYSICS, 2019, 46 (12) : 5748 - 5757
  • [40] Verification of patient-specific dose distributions in proton therapy using a commercial two-dimensional ion chamber array
    Arjomandy, Bijan
    Sahoo, Narayan
    Ciangaru, George
    Zhu, Ronald
    Song, Xiaofei
    Gillin, Michael
    MEDICAL PHYSICS, 2010, 37 (11) : 5831 - 5837