Range verification in heavy-ion therapy using a hadron tumour marker

被引:0
|
作者
Kasanda, E. [1 ,2 ]
Bildstein, V [1 ]
Hymers, D. [1 ,3 ]
Easter, J. [1 ]
Richard, A. L. [4 ,5 ,8 ]
Baumann, T. [4 ]
Spyrou, A. [4 ,5 ]
Hoehr, C. [6 ,7 ]
Muecher, D. [1 ,3 ,6 ]
机构
[1] Univ Guelph, Dept Phys, 50 Stone Rd E, Guelph, ON N1G 2W1, Canada
[2] Univ Bern, Lab High Energy Phys, Sidlerstr 5, CH-3012 Bern, Switzerland
[3] Univ Cologne, Inst Kernphys, Zulpicher Str 77, D-50937 Cologne, Germany
[4] Michigan State Univ, Facil Rare Isotope Beams, E Lansing, MI 48824 USA
[5] Michigan State Univ, Dept Phys & Astron, E Lansing, MI 48824 USA
[6] TRIUMF, 4004 Wesbrook Mall, Vancouver, BC V6T 2A3, Canada
[7] Univ Victoria, Dept Phys & Astron, 3800 Finnerty Rd, Victoria, BC V8P 5C2, Canada
[8] Lawrence Livermore Natl Lab, Livermore, CA USA
基金
加拿大自然科学与工程研究理事会;
关键词
hadron therapy; range verification; tumour marker; spectroscopy; PROTON; RADIOTHERAPY; FACILITY;
D O I
10.1088/1361-6560/acf557
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Anew method to estimate the range of an ion beam in a patient during heavy-ion therapy was investigated, which was previously verified for application in proton therapy. Approach. The method consists of placing a hadron tumour marker (HTM) close to the tumour. As the treatment beam impinges on the HTM, the marker undergoes nuclear reactions. When theHTMmaterial is carefully chosen, the activation results in the emission of several delayed, characteristic gamma rays, whose intensities are correlated with the remaining range inside the patient. When not just one but two reaction channels are investigated, the ratio between these two gamma ray emissions can be measured, and the ratio is independent of any beam delivery uncertainties. Main results. A proof-of-principle experiment with an 16Oion beam and Ag foils asHTMwas successfully executed. The Ag-107(O-16, (x))Sb-112 and the Ag-107(O-16, x)(114) Sb reaction channels were identified as suitable for theHTM technique. When only one gamma-ray emission is measured, the resulting range-uncertainty estimation is at the 0.5mmscale. When both channels are considered, a theoretical limit on the range uncertainty of a clinical fiducal marker was found to be +/- 290 mu m. Significance. Range uncertainty of a heavy-ion beam limits the prescribed treatment plan for cancer patients, especially the direction of the ion beam in relation to any organ at risk. An easy to implement range-verification technique which can be utilized during clinical treatment would allow treatment plans to take full advantage of the sharp falloff of the Bragg peak without the risk of depositing excessive dose into healthy tissue.
引用
收藏
页数:13
相关论文
共 43 条
  • [21] Feasibility of Using Distal Endpoints for In-Room PET Range Verification of Proton Therapy
    Grogg, Kira
    Zhu, Xuping
    Min, Chul Hee
    Winey, Brian
    Bortfeld, Thomas
    Paganetti, Harald
    Shih, Helen A.
    El Fakhri, Georges
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (05) : 3290 - 3297
  • [22] Study of the heavy-ion collisions using the femtoscopy correlations of the two protons system
    Pawlowska, Diana
    PHOTONICS APPLICATIONS IN ASTRONOMY, COMMUNICATIONS, INDUSTRY, AND HIGH ENERGY PHYSICS EXPERIMENTS 2017, 2017, 10445
  • [23] Potential benefits of using radioactive ion beams for range margin reduction in carbon ion therapy
    Sokol, Olga
    Cella, Laura
    Boscolo, Daria
    Horst, Felix
    Oliviero, Caterina
    Pacelli, Roberto
    Palma, Giuseppe
    De Simoni, Micol
    Conson, Manuel
    Caroprese, Mara
    Weber, Ulrich
    Graeff, Christian
    Parodi, Katia
    Durante, Marco
    SCIENTIFIC REPORTS, 2022, 12 (01):
  • [24] Experimental verification of ion range calculation in a treatment planning system using a flat-panel detector
    Telsemeyer, Julia
    Ackermann, Benjamin
    Ecker, Swantje
    Jaekel, Oliver
    Martisikova, Maria
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (14) : 3737 - 3747
  • [25] Monte Carlo investigation of sub-millimeter range verification in carbon ion radiation therapy using interaction vertex imaging
    Hymers, Devin
    Mucher, Dennis
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2019, 5 (04):
  • [26] Assessment of the induced radioactivity in the treatment room of the heavy-ion medical machine in Wuwei using PHITS
    Luo, Ying
    Huang, Sheng-Cong
    Zhang, Hui
    Mao, Hai-Jun
    Li, Qiang
    Dai, Zhong-Ying
    NUCLEAR SCIENCE AND TECHNIQUES, 2023, 34 (02)
  • [27] Noise evaluation of prompt-gamma technique for proton-therapy range verification using a Compton Camera
    Ortega, P. G.
    Torres-Espallardo, I.
    Boehlen, T. T.
    Cerutti, F.
    Chin, M. P. W.
    Ferrari, A.
    Gillam, J. E.
    Lacasta, C.
    Llosa, G.
    Oliver, J.
    Rafecas, M.
    Sala, P. R.
    Solevi, P.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [28] The Potential of Heavy-Ion Therapy to Improve Outcomes for Locally Advanced Non-Small Cell Lung Cancer
    Chun, Stephen G.
    Solberg, Timothy D.
    Grosshans, David R.
    Quynh-Nhu Nguyen
    Simone, Charles B., II
    Mohan, Radhe
    Liao, Zhongxing
    Hahn, Stephen M.
    Herman, Joseph M.
    Frank, Steven J.
    FRONTIERS IN ONCOLOGY, 2017, 7
  • [29] Few-seconds range verification with short-lived positron emitters in carbon ion therapy
    Cuccagna, Caterina
    Battistoni, Giuseppe
    Bisogni, Maria Giuseppina
    Cerello, Piergiorgio
    Del Guerra, Alberto
    Ferrero, Veronica
    Fiorina, Elisa
    Morrocchi, Matteo
    Pennazio, Francesco
    Sacchi, Roberto
    Amaldi, Ugo
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2024, 118
  • [30] New concept of a range verification system for proton therapy using a photon counting detector
    Kim, Jin Sung
    An, Su Jung
    Chung, Yong Hyun
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 677 : 18 - 21