The Use of Photoplethysmography for Blood Glucose Estimation by Noninvasive Method

被引:0
|
作者
Bavkar, Vandana C. [1 ]
Shinde, Arundhati [1 ]
机构
[1] Bharati Vidyapeeth Deemed Be Univ, Dept Elect, Coll Engn, Pune 411043, Maharashtra, India
来源
SMART SENSORS MEASUREMENT AND INSTRUMENTATION, CISCON 2021 | 2023年 / 957卷
关键词
Blood glucose; Noninvasive; Photoplethysmography; Feature extraction; Neural network;
D O I
10.1007/978-981-19-6913-3_21
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Noninvasive blood glucose estimation system based on photoplethysmography is proposed in this paper. Photoplethysmography (PPG) is an optical technique which uses infrared light to determine the fluctuations in blood stream in the human body with every pulse. However literature reveals that, a functional correlation exists among pulse signal waveform and the glucose contents in the blood. Many researchers have shown estimation of glucose using different spectroscopy techniques which involves an optical sensor. The key involvement of this paper is withdrawal of different features with respect to time domain as well as frequency domain. Exploration of single pulse is also carried out with different features. A PPG data of 182 random people with varied health conditions like diabetic, blood pressure condition is recorded for about 1 min duration. The glucose estimation is done in two ways: the first one is feature extraction from complete PPG signal of a patient and the second one is single pulse wave analysis. All the features from above-mentioned methods are transformed into feature vector which acts as input to system and estimation of blood glucose is performed. We used Clarke Error Grid Analysis for blood glucose estimation which is clinically accepted. With time and frequency domain features we got 43.75% samples in region A and 50% samples in region B, so total 93.75% samples are in regions A and B. Using single pulse wave analysis we got 59.66% samples in region A and 34.61% samples in region B, so total 94.27% samples are in clinically accepted regions (A and B). As single pulse wave analysis shows significant improvement in region A (20% of actual blood glucose value), this method is good selection for glucose measurement.
引用
收藏
页码:323 / 335
页数:13
相关论文
共 50 条
  • [41] Towards Robust Blood Pressure Estimation From Pulse Wave Velocity Measured by Photoplethysmography Sensors
    Byfield, Richard
    Miller, Morgan
    Miles, Jonathan
    Guidoboni, Giovanna
    Lin, Jian
    IEEE SENSORS JOURNAL, 2022, 22 (03) : 2475 - 2483
  • [42] A Wireless Noninvasive Blood Pressure Measurement System Using MAX30102 and Random Forest Regressor for Photoplethysmography Signals
    Tjitra, Michelle Annice
    Anju, Nagisa Eremia
    Sudiana, Dodi
    Rizkinia, Mia
    COMPUTERS, 2024, 13 (05)
  • [43] Noninvasive estimation of blood glucose and HbA1c using Quantum Machine Learning technique
    Sridevi, Parama
    Rabbani, Masud
    Aziz, Md Hasanul
    Upama, Paramita Basak
    Mamun, Sayed Mashroor
    Khan, Rumi Ahmed
    Ahamed, Sheikh Iqbal
    MACHINE LEARNING WITH APPLICATIONS, 2025, 19
  • [44] Personalized Blood Pressure Estimation Using Photoplethysmography: A Transfer Learning Approach
    Leitner, Jared
    Chiang, Po-Han
    Dey, Sujit
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2022, 26 (01) : 218 - 228
  • [45] Gingival crevicular fluid-collecting device for noninvasive blood glucose monitoring
    Yamaguchi, M
    Kambe, S
    Naitoh, K
    Kamei, T
    Yoshida, H
    SECOND JOINT EMBS-BMES CONFERENCE 2002, VOLS 1-3, CONFERENCE PROCEEDINGS: BIOENGINEERING - INTEGRATIVE METHODOLOGIES, NEW TECHNOLOGIES, 2002, : 1809 - 1810
  • [46] Noninvasive Blood Glucose Analysis Based on Near-Infrared Reflectance Spectroscopy
    Lu Xiao-feng
    Zhang Ting-lin
    Xiao Feng
    Li Guang
    Wang You
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36 (07) : 2312 - 2317
  • [47] Beat-to-Beat Blood Pressure Estimation by Photoplethysmography and Its Interpretation
    Fleischhauer, Vincent
    Feldheiser, Aarne
    Zaunseder, Sebastian
    SENSORS, 2022, 22 (18)
  • [48] A Noninvasive Method of Monitoring Blood Glucose Levels by Using Triple-Band Monopole Antenna
    Sharaf, Faten
    Elsheakh, Dalia N.
    Eldamak, Angie R.
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2025, 67 (01)
  • [49] Microwave Noninvasive Blood Glucose Monitoring Sensor: Human Clinical Trial Results
    Choi, Heungjae
    Luzio, Steve
    Beutler, Jan
    Porch, Adrian
    2017 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM (IMS), 2017, : 872 - 875
  • [50] Internal floating reference method for noninvasive measurement of blood glucose with near-infrared spectroscopy
    Luo, Yun-Han
    Li, Ship-Ing
    Huang, Fu-Rong
    Chen, Zhe