Noninvasive blood glucose estimation system based on photoplethysmography is proposed in this paper. Photoplethysmography (PPG) is an optical technique which uses infrared light to determine the fluctuations in blood stream in the human body with every pulse. However literature reveals that, a functional correlation exists among pulse signal waveform and the glucose contents in the blood. Many researchers have shown estimation of glucose using different spectroscopy techniques which involves an optical sensor. The key involvement of this paper is withdrawal of different features with respect to time domain as well as frequency domain. Exploration of single pulse is also carried out with different features. A PPG data of 182 random people with varied health conditions like diabetic, blood pressure condition is recorded for about 1 min duration. The glucose estimation is done in two ways: the first one is feature extraction from complete PPG signal of a patient and the second one is single pulse wave analysis. All the features from above-mentioned methods are transformed into feature vector which acts as input to system and estimation of blood glucose is performed. We used Clarke Error Grid Analysis for blood glucose estimation which is clinically accepted. With time and frequency domain features we got 43.75% samples in region A and 50% samples in region B, so total 93.75% samples are in regions A and B. Using single pulse wave analysis we got 59.66% samples in region A and 34.61% samples in region B, so total 94.27% samples are in clinically accepted regions (A and B). As single pulse wave analysis shows significant improvement in region A (20% of actual blood glucose value), this method is good selection for glucose measurement.
引用
收藏
页码:323 / 335
页数:13
相关论文
共 50 条
  • [21] Noninvasive In Vivo Estimation of Blood-Glucose Concentration by Monte Carlo Simulation
    Haque, Chowdhury Azimul
    Hossain, Shifat
    Kwon, Tae-Ho
    Kim, Ki-Doo
    SENSORS, 2021, 21 (14)
  • [22] Advancing Continuous Blood Pressure Estimation with Transformer on Photoplethysmography in Operation Room
    Lee, Nayoung
    Kim, Sang-Hyun
    Lee, Misoon
    Woo, Jiyoung
    IEEE ACCESS, 2024, 12 : 90486 - 90500
  • [23] DeepCNAP: A Deep Learning Approach for Continuous Noninvasive Arterial Blood Pressure Monitoring Using Photoplethysmography
    Kim, Dong-Kyu
    Kim, Young-Tak
    Kim, Hakseung
    Kim, Dong-Joo
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2022, 26 (08) : 3697 - 3707
  • [24] A Continuous Blood Pressure Estimation Method Using Photoplethysmography by GRNN-Based Model
    Li, Zheming
    He, Wei
    SENSORS, 2021, 21 (21)
  • [25] EMD-Based Noninvasive Blood Glucose Estimation from PPG Signals Using Machine Learning Algorithms
    Satter, Shama
    Turja, Mrinmoy Sarker
    Kwon, Tae-Ho
    Kim, Ki-Doo
    APPLIED SCIENCES-BASEL, 2024, 14 (04):
  • [26] Noninvasive methods for blood glucose measurement
    Bazaev N.A.
    Selishchev S.V.
    Biomedical Engineering, 2007, 41 (1) : 42 - 50
  • [27] The effect of spectral photoplethysmography amplification and its application in dynamic spectrum for effective noninvasive detection of blood components
    Awelisah, Yussif Moro
    Li, Gang
    Ijaz, Muhammad
    Lin, Ling
    OPTICS AND LASER TECHNOLOGY, 2021, 133
  • [28] A Noninvasive Accurate Measurement of Blood Glucose Levels with Raman Spectroscopy of Blood in Microvessels
    Li, Nan
    Zang, Hang
    Sun, Huimin
    Jiao, Xianzhi
    Wang, Kangkang
    Liu, Timon Cheng-Yi
    Meng, Yaoyong
    MOLECULES, 2019, 24 (08):
  • [29] New optical method for noninvasive blood glucose measurement by optical ultrasonic modulation
    Zhu, Lili
    Lin, Jieqing
    Xie, Wenming
    Li, Hui
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS IV, 2010, 7845
  • [30] Noninvasive blood glucose monitoring by novel optical fiber probe
    Maruo, K
    Chin, J
    Tamura, M
    OPTICAL DIAGNOSTICS AND SENSING OF BIOLOGICAL FLUIDS AND GLUCOSE AND CHOLESTEROL MONITORING II, 2002, 4624 : 20 - 27