Retrospective Analysis of Intra-Aortic Balloon Pump Use in Cardiology Ward Patients Undergoing Coronary Angiography between 2012 and 2020

被引:0
|
作者
Bochenek, Tomasz [1 ,2 ]
Sowula, Patrycja [1 ]
Rodak, Malgorzata [1 ]
Rybicka-Musialik, Anna [2 ]
Gruchlik, Bartosz [2 ]
Mizia-Stec, Katarzyna [1 ,2 ]
机构
[1] Med Univ Silesiaia, Sch Med Katowice, Dept Cardiol 1, PL-40055 Katowice, Poland
[2] Uppersilesian Med Ctr, PL-40635 Katowice, Poland
关键词
intra-aortic balloon pump; percutaneous coronary interventions; outcome; MYOCARDIAL-INFARCTION; COUNTERPULSATION; INTERVENTION; GUIDELINES; ELEVATION; IMPACT; SHOCK;
D O I
10.3390/jcm12041567
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We aimed to evaluate the rate and risk factors of in-hospital mortality in patients undergoing coronary angiography/angioplasty with IABP use as support. We included 214 patients (mean age: 67.5 +/- 7.5 years, M/F: 143/71) with an IABP used as the periprocedural support between 2012 and 2020. The main indications for an IABP were cardiogenic shock (143 pts; 66.8%: 55 survivors (51.9%)/88 non-survivors (81.5%); p < 0.001) and infarction with an initial significant impairment of ventricular function (34 pts; 15.9%: 21 (19.8%)/13 (12%); p = 0.12). In-hospital death was the endpoint of this study. In-hospital death occurred in 108 (50.5%, M/F: 69.4%/30.6%) patients. The mean hospitalization time was 7 days (2-13); deaths occurred more frequently on the first day after the procedure (1 (1-3 days) vs. 3 (1-8), p < 0.001); and the mean hospitalization time was 2 days (1-6) for non-survivors vs. 11 days (7-17) for survivors (p < 0.001). Regarding the patients who did not survive, they were older (69 vs. 66.5, p = 0.043), their LVEF was lower (0-15%: 15 (13.9%) vs. 12 (11.3%); 16-40%: 73 (67.6%) vs. 65 (61.3%); >40%: 14 (13%) vs. 29 (27.4%); p = 0.007), and hyperlipidemia was less common (30 (27.8%) vs. 55 (51.9%) pts, p = 0.001) than in those who survived. The IABP is still a method for cardiac support; however, mortality limits its use.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Short-term outcomes of preoperative intra-aortic balloon pump use in patients undergoing adjunctive coronary endarterectomy: a retrospective observational study
    Wang, Liangshan
    Hao, Xing
    Wang, Xiaomeng
    Gu, Chengxiong
    Wang, Hong
    Hou, Xiaotong
    PERFUSION-UK, 2018, 33 (06): : 426 - 432
  • [2] Contemporary use and results of intra-aortic balloon pump counterpulsation
    Gargiulo, Giuseppe
    Stabile, Eugenio
    Perrino, Cinzia
    Scudiero, Fernando
    Scudiero, Laura
    Schiattarella, Gabriele G.
    Franzone, Anna
    Sannino, Anna
    Giugliano, Giuseppe
    Trimarco, Bruno
    Esposito, Giovanni
    MINERVA CARDIOANGIOLOGICA, 2016, 64 (01): : 84 - 91
  • [3] Preventive Use of Intra-Aortic Balloon Pump in Patients Undergoing High-Risk Coronary Artery Bypass Grafting: A Retrospective Study
    Zhang, Jingchao
    Lang, Yan
    Guo, Longhui
    Song, Xiaodong
    Shu, Liliang
    Su, Gang
    Liu, Hai
    Xu, Jing
    MEDICAL SCIENCE MONITOR, 2015, 21 : 855 - 860
  • [4] Preoperative intra-aortic balloon pump inserted in acute myocardial infarction patients without cardiogenic shock undergoing surgical coronary revascularization
    Yang, Feng
    Wang, Liangshan
    Hou, Dengbang
    Wang, Jinhong
    Wang, Xiaomeng
    Cui, Yongchao
    Hao, Xing
    Xing, Zhichen
    Jiang, Chunjing
    Du, Zhongtao
    Yang, Xiaofang
    Miao, Na
    Jiang, Yu
    Xing, Jialin
    Hou, Xiaotong
    PERFUSION-UK, 2020, 35 (02): : 145 - 153
  • [5] Intraoperative intra-aortic balloon pump improves 30-day outcomes of patients undergoing extensive coronary endarterectomy
    Wu, Zhen
    Liu, Changcheng
    Fang, Ying
    Wei, Hua
    Gu, Chengxiong
    JOURNAL OF CARDIOTHORACIC SURGERY, 2020, 15 (01)
  • [6] Use of Novel 6 French Intra-Aortic Balloon Pump Catheter for Patients Undergoing Percutaneous Coronary Intervention
    Yamada, Takeshi
    Mizuguchi, Yukio
    Sakamoto, Shingo
    Taniguchi, Norimasa
    Nakajima, Shunsuke
    Takahashi, Akihiko
    ASAIO JOURNAL, 2013, 59 (05) : 493 - 496
  • [7] Efficacy of Prophylactic Intra-Aortic Balloon Pump Therapy in Chronic Heart Failure Patients Undergoing Cardiac Surgery
    Yildirim, Yalin
    Pecha, Simon
    Kubik, Mathias
    Alassar, Yousuf
    Deuse, Tobias
    Hakmi, Samer
    Reichenspurner, Hermann
    ARTIFICIAL ORGANS, 2014, 38 (11) : 967 - 972
  • [8] The Use of Intra-Aortic Balloon Pump in Patients. Undergoing Heart Valve Replacement: Outcome and Risk Analysis
    Zhang, Xi-Wu
    Song, Zhi-Gang
    Wang, Lv
    Lu, Fang-Lin
    Han, Lin
    Zou, Liang-Jian
    Xu, Ji-Bin
    Xu, Zhi-Yun
    JOURNAL OF HEART VALVE DISEASE, 2014, 23 (04) : 458 - 462
  • [9] Intra-aortic balloon pump use does not affect the renal function in patients undergoing off pump coronary artery bypass surgery
    Muniraju, Geetha
    Pandey, Sourabh
    Chakravarthy, Murali
    Krishnamoorthy, Jayaprakash
    Narayan, Sandeep
    Jawali, Vivek
    ANNALS OF CARDIAC ANAESTHESIA, 2011, 14 (03) : 188 - 191
  • [10] Pro: Prophylactic Preoperative Use of an Intra-aortic Balloon Pump Is Indicated in High-Risk Coronary Patients Undergoing Coronary Artery Bypass Grafting
    Zaky, Ahmed
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2015, 29 (02) : 532 - 533