An audit of patient radiation doses in interventional radiology at a South African hospital

被引:1
|
作者
Slave, Oneile [1 ]
Mahomed, Nasreen [1 ]
机构
[1] Univ Witwatersrand, Fac Hlth Sci, Dept Radiol, Johannesburg, South Africa
来源
SA JOURNAL OF RADIOLOGY | 2023年 / 27卷 / 01期
关键词
Interventional radiology; diagnostic reference level; kerma air product; reference point air kerma; fluoroscopy time; DIAGNOSTIC REFERENCE LEVELS; MULTICENTER; EXPOSURE; IR;
D O I
10.4102/sajr.v27i1.2559
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Interventional radiology (IR) is becoming more relevant in patient care and is associated with increased patient radiation exposure and radiation-induced adverse effects. Diagnostic reference levels (DRLs) are crucial for radiation control. There is a paucity of published DRLs for IR in South Africa and sub-Saharan Africa. Objectives: This study aimed to determine local DRLs for fluoroscopically-guided IR procedures and compare the achieved DRLs with published local and international DRLs. Method: Retrospective, descriptive, single-centre study. Kerma air product (KAP), reference point air kerma (Ka,r) and fluoroscopy time (FT) were collected for patients (12 years and older) who underwent IR procedures at a university hospital from 01 January 2019 to 31 December 2019. The 75th percentile of the distribution of each dose parameter (KAP, Ka,r and FT) per procedure was calculated and taken as the local diagnostic reference levels (LDRL). The established LDRLs were compared to published DRLs. Results: A total of 564 cases were evaluated. The 13 most frequent procedures (with 15 or more cases) represented 86.1% (487/564). Percutaneous transhepatic biliary drainage was the most common procedure (n = 146, 25.9%). Diagnostic cerebral angiogram DRLs exceeded the published DRL data ranges for all parameters (DRL 209.3), and interventional cerebral angiogram exceeded published ranges (DRL 275). Uterine artery embolisation (UAE) exceeded these ranges for KAP and Ka,r. (KAP-954.9 Gy/cm2, Ka,r-2640.8 mGy). Conclusion: The LDRLs for diagnostic cerebral angiogram, interventional cerebral angiogram and UAE exceeded published international DRL ranges. These procedures require radiation optimisation as recommended by the International Commission on Radiological Protection (ICRP). Contribution: In addition to informing radiation protection practices at the level of the institution, the established LDRLs contribute towards Regional and National DRLs.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Radiation safety in pediatric interventional radiology: Step Lightly
    Sidhu, Manrita
    PEDIATRIC RADIOLOGY, 2010, 40 (04) : 511 - 513
  • [32] The Effort for Radiation Protection Increases the Value of Interventional Radiology
    Abe, Toshi
    INTERVENTIONAL RADIOLOGY, 2022, 7 (02) : 37 - 39
  • [33] Evaluation of patient radiation doses using DAP meter in diagnostic radiology procedures in Birjand, Iran
    Zarghani, Hassan
    Jabbari, Masoud
    Pandesh, Sajjad
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2023, 54 (01)
  • [34] Radiation protection in interventional radiology.
    Adamus, R.
    Loose, R.
    Wucherer, M.
    Uder, M.
    Galster, M.
    RADIOLOGE, 2016, 56 (03): : 275 - 281
  • [35] Re: An audit of out or hours interventional vascular radiology
    Ashleigh, R
    Butterfield, JS
    Chalmers, N
    Murphy, G
    Asquith, J
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2004, 27 (01) : 103 - 103
  • [36] A COMPARISON OF OCCUPATIONAL DOSES IN CONVENTIONAL AND INTERVENTIONAL RADIOLOGY IN IRAN
    Mianji, Fereidoun
    Gheshlaghi, Fariba
    Darabi, Majid
    Kardan, Mohammad Reza
    Hosseinipanah, Mirshahram
    Zakeri, Farideh
    RADIATION PROTECTION DOSIMETRY, 2018, 178 (01) : 37 - 47
  • [37] HAND AND EYE LENS DOSES TO CARDIOLOGIST IN INTERVENTIONAL RADIOLOGY
    Repse, Kristina
    Gedvilas, Marius
    MEDICAL PHYSICS IN THE BALTIC STATES, 2013, : 137 - 139
  • [38] Interventional Radiology and the Pancreatic Cancer Patient
    Brown, Daniel B.
    Narayanan, Govindarajan
    CANCER JOURNAL, 2012, 18 (06) : 591 - 601
  • [39] Staff extremity doses in interventional radiology. Results of the ORAMED measurement campaign
    Nikodemova, D.
    Brodecki, M.
    Carinou, E.
    Domienik, J.
    Donadille, L.
    Koukorava, C.
    Krim, S.
    Ruiz-Lopez, N.
    Sans-Merce, M.
    Struelens, L.
    Vanhavere, F.
    Zaknoune, R.
    RADIATION MEASUREMENTS, 2011, 46 (11) : 1210 - 1215
  • [40] Estimating brain radiation dose to the main operator in interventional radiology
    Garzon, W. J.
    Andrade, G.
    De Barros, V. S. M.
    Ribeiro, L. T.
    Khoury, H. J.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2020, 40 (04) : 1170 - 1177