An audit of patient radiation doses in interventional radiology at a South African hospital

被引:1
|
作者
Slave, Oneile [1 ]
Mahomed, Nasreen [1 ]
机构
[1] Univ Witwatersrand, Fac Hlth Sci, Dept Radiol, Johannesburg, South Africa
来源
SA JOURNAL OF RADIOLOGY | 2023年 / 27卷 / 01期
关键词
Interventional radiology; diagnostic reference level; kerma air product; reference point air kerma; fluoroscopy time; DIAGNOSTIC REFERENCE LEVELS; MULTICENTER; EXPOSURE; IR;
D O I
10.4102/sajr.v27i1.2559
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Interventional radiology (IR) is becoming more relevant in patient care and is associated with increased patient radiation exposure and radiation-induced adverse effects. Diagnostic reference levels (DRLs) are crucial for radiation control. There is a paucity of published DRLs for IR in South Africa and sub-Saharan Africa. Objectives: This study aimed to determine local DRLs for fluoroscopically-guided IR procedures and compare the achieved DRLs with published local and international DRLs. Method: Retrospective, descriptive, single-centre study. Kerma air product (KAP), reference point air kerma (Ka,r) and fluoroscopy time (FT) were collected for patients (12 years and older) who underwent IR procedures at a university hospital from 01 January 2019 to 31 December 2019. The 75th percentile of the distribution of each dose parameter (KAP, Ka,r and FT) per procedure was calculated and taken as the local diagnostic reference levels (LDRL). The established LDRLs were compared to published DRLs. Results: A total of 564 cases were evaluated. The 13 most frequent procedures (with 15 or more cases) represented 86.1% (487/564). Percutaneous transhepatic biliary drainage was the most common procedure (n = 146, 25.9%). Diagnostic cerebral angiogram DRLs exceeded the published DRL data ranges for all parameters (DRL 209.3), and interventional cerebral angiogram exceeded published ranges (DRL 275). Uterine artery embolisation (UAE) exceeded these ranges for KAP and Ka,r. (KAP-954.9 Gy/cm2, Ka,r-2640.8 mGy). Conclusion: The LDRLs for diagnostic cerebral angiogram, interventional cerebral angiogram and UAE exceeded published international DRL ranges. These procedures require radiation optimisation as recommended by the International Commission on Radiological Protection (ICRP). Contribution: In addition to informing radiation protection practices at the level of the institution, the established LDRLs contribute towards Regional and National DRLs.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] MCNP Simulation of Radiation Doses Distributions in a Water Phantoms Simulating Interventional Radiology Patients
    He, Wenjun
    Mah, Eugene
    Huda, Walter
    Selby, Bayne
    Yao, Hai
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [22] An audit of out of hours interventional vascular radiology
    Surash, S
    Robertson, I
    Calvey, TAJ
    Kessel, D
    Patel, J
    Kent, PJ
    Berridge, D
    Scott, DJA
    Kester, RC
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2003, 25 (06) : 573 - 577
  • [23] Evaluation of patient doses and lens radiation doses to interventional cardiologists in a nationwide survey in Chile
    Ubeda, Carlos
    Vano, Eliseo
    Gonzalez, Luciano
    Miranda, Patricia
    Valenzuela, Edith
    Vergara, Francisco
    Guarda, Eduardo
    RADIATION PROTECTION DOSIMETRY, 2013, 157 (01) : 36 - 43
  • [24] Staff Doses in Interventional Radiology: A National Survey
    Mariano Sanchez, Roberto
    Vano, Eliseo
    Fernandez, Jose M.
    Rosales, Francisco
    Sotil, Jesus
    Carrera, Francisco
    Garcia, Maria A.
    Soler, Maria M.
    Hernandez-Armas, Jose
    Martinez, Luis C.
    Verdu, Jose F.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2012, 23 (11) : 1496 - 1501
  • [25] Patient Radiation Dose Reduction Considerations in a Contemporary Interventional Radiology Suite
    Catherine Panick
    Kevin Wunderle
    Mark Sands
    Charles Martin
    CardioVascular and Interventional Radiology, 2018, 41 : 1925 - 1934
  • [26] Managing occupational doses with smartphones in interventional radiology
    Sanchez, Roberto M.
    Fernandez, Daniel
    Vano, Eliseo
    Fernandez, Jose M.
    MEDICAL PHYSICS, 2021, 48 (10) : 5830 - 5836
  • [27] Radiation Doses to Operators in Hepatobiliary Interventional Procedures
    Degiorgio, Sarah
    Gerasia, Roberta
    Liotta, Ferdinanda
    Maruzzelli, Luigi
    Cortis, Kelvin
    Miraglia, Roberto
    Luca, Angelo
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2018, 41 (05) : 772 - 780
  • [28] RADIATION DOSES TO PATIENTS IN INTERVENTIONAL CORONARY PROCEDURES-ESTIMATION OF UPDATED NATIONAL REFERENCE LEVELS BY DOSE AUDIT
    Georges, Jean-Louis
    Belle, Loic
    Etard, Cecile
    Azowa, Jean-Baptiste
    Albert, Franck
    Pansieri, Michel
    Monsegu, Jacques
    Barbou, Franck
    Trouillet, Charlotte
    Leddet, Pierre
    Livarek, Bernard
    Marcaggi, Xavier
    Hanssen, Michel
    Cattan, Simon
    RADIATION PROTECTION DOSIMETRY, 2017, 175 (01) : 17 - 25
  • [29] Occupational Radiation Protection in Interventional Radiology: A Joint Guideline of the Cardiovascular and Interventional Radiology Society of Europe and the Society of Interventional Radiology
    Miller, Donald L.
    Vano, Eliseo
    Bartal, Gabriel
    Balter, Stephen
    Dixon, Robert
    Padovani, Renato
    Schueler, Beth
    Cardella, John F.
    de Baere, Thierry
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2010, 33 (02) : 230 - 239
  • [30] Occupational Radiation Protection in Interventional Radiology: A Joint Guideline of the Cardiovascular and Interventional Radiology Society of Europe and the Society of Interventional Radiology
    Miller, Donald L.
    Vano, Eliseo
    Bartal, Gabriel
    Balter, Stephen
    Dixon, Robert
    Padovani, Renato
    Schueler, Beth
    Cardella, John F.
    de Baere, Thierry
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2010, 21 (05) : 607 - 615