Direct comparison of diagnostic and clinical values between Tc-99 m DPD and Tc-99 m PYP scintigraphy in patients with cardiac amyloidosis

被引:0
|
作者
Park, Yong-Jin [1 ,2 ]
Lee, Joohee [3 ]
Kim, Darae [4 ]
Choi, Jin-Oh [4 ]
Kim, Seok Jin [5 ]
Kim, Kihyun [5 ]
Choi, Joon Young [1 ]
机构
[1] Sungkyunkwan Univ, Samsung Med Ctr, Dept Nucl Med, Sch Med, 81 Irwon Ro, Seoul 06351, South Korea
[2] Ajou Univ, Sch Med, Dept Nucl Med, Med Ctr, Suwon 16499, South Korea
[3] CHA Univ, CHA Ilsan Med Ctr, Dept Nucl Med, Goyang 10414, South Korea
[4] Sungkyunkwan Univ, Heart Vasc Stroke Inst, Samsung Med Ctr, Dept Med,Sch Med, Seoul 06351, South Korea
[5] Sungkyunkwan Univ, Samsung Med Ctr, Dept Med, Div Hematol Oncol,Sch Med, Seoul 06351, South Korea
基金
新加坡国家研究基金会;
关键词
Cardiac amyloidosis; Tc-99m DPD; Tc-99m PYP; Perugini system; Dorbala system;
D O I
10.1186/s12880-023-01054-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundTechnetium-99 m 3,3-diphosphono-1,2-propanodicarboxylic acid (DPD) and technetium-99 m sodium pyrophosphate (PYP) are the two most commonly used radiotracers for cardiac amyloidosis (CA), but no studies have directly compared them. Therefore, in this study, we directly compared the diagnostic and clinical utility of DPD and PYP scintigraphy in patients with CA.MethodsTen patients with CA were enrolled. Eight clinical variables and 12 scintigraphic parameters were used. Clinical variables were age, sex, estimated glomerular filtration rate (eGFR), N-terminal pro brain natriuretic peptide (NT-proBNP), and the results of electromyography (EMG), a sensory test, electrocardiogram, and echocardiography (EchoCG). Four heart retention ratios (heart/whole-body profile, heart/pelvis, heart/skull, and heart/contralateral lung) were calculated from the DPD and PYP scans and two visual scoring systems (Perugini and Dorbala systems) were used. Comparative analyses were performed between radiotracers and between visual scoring systems using clinical variables and scintigraphic parameters.ResultsTwenty DPD parameters and nine PYP parameters had significant associations with age, eGFR, NT-proBNP, EchoCG, and EMG. DPD parameters had more frequent significant associations with clinical variables than PYP parameters. Compared to visual scores in the DPD scan, the proportion of patients with higher visual scores in the PYP scan was relatively greater than those with lower visual scores, and there were more patients with a visual score of 2 or higher in PYP scans than DPD scans.ConclusionsDPD scintigraphy may reflect the disease severity of CA better than PYP scintigraphy, whereas PYP scintigraphy may be a more sensitive imaging modality for identifying CA involvement.
引用
收藏
页数:10
相关论文
共 19 条
  • [1] Direct comparison of diagnostic and clinical values between Tc-99 m DPD and Tc-99 m PYP scintigraphy in patients with cardiac amyloidosis
    Yong-Jin Park
    Joohee Lee
    Darae Kim
    Jin-Oh Choi
    Seok Jin Kim
    Kihyun Kim
    Joon Young Choi
    BMC Medical Imaging, 23
  • [2] Follow-up Tc-99 m pyrophosphate cardiac scan for patients with transthyretin cardiac amyloidosis treated with tafamidis
    Lee, Tse-Hao
    Wang, Yuh-Feng
    Hu, Lien-Hsin
    Peng, Nan-Jing
    Chang, Chih-Yung
    Huang, Wen-Sheng
    JAPANESE JOURNAL OF RADIOLOGY, 2023, 41 (08) : 882 - 888
  • [3] Follow-up Tc-99 m pyrophosphate cardiac scan for patients with transthyretin cardiac amyloidosis treated with tafamidis
    Tse-Hao Lee
    Yuh-Feng Wang
    Lien-Hsin Hu
    Nan-Jing Peng
    Chih-Yung Chang
    Wen-Sheng Huang
    Japanese Journal of Radiology, 2023, 41 : 882 - 888
  • [4] Improving evaluation for TTR amyloidosis by interactive filtering of Tc-99 m PYP SPECT images. The role for "clean blood pool" imaging
    Hansen, Christopher L.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2023, 30 (06) : 2418 - 2426
  • [5] Tc-99m pyrophosphate scintigraphy for cardiac amyloidosis: concordance between planar and SPECT/CT imaging
    Coskun, Nazim
    Kartal, M. Oguz
    Erdogan, A. Sinem
    Tufekcioglu, Omac
    Ozdemir, Elif
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2022, 38 (09) : 2081 - 2088
  • [6] Tc-99m pyrophosphate scintigraphy for cardiac amyloidosis: concordance between planar and SPECT/CT imaging
    Nazim Coskun
    M. Oguz Kartal
    A. Sinem Erdogan
    Omac Tufekcioglu
    Elif Ozdemir
    The International Journal of Cardiovascular Imaging, 2022, 38 : 2081 - 2088
  • [7] Cardiac Amyloidosis Detected on Tc-99m Bone Scan
    Lu Y.
    Groth J.V.
    Emmadi R.
    Nuclear Medicine and Molecular Imaging, 2015, 49 (1) : 78 - 80
  • [8] Tc-99m-pyrophosphate scintigraphy for the diagnosis of ATTR cardiac amyloidosis: Comparison of quantitative and semi-quantitative approaches
    Claudine Régis
    François Harel
    Patrick Martineau
    Jean Grégoire
    Gad Abikhzer
    Daniel Juneau
    Matthieu Pelletier-Galarneau
    Journal of Nuclear Cardiology, 2020, 27 : 1808 - 1815
  • [9] Tc-99m-pyrophosphate scintigraphy for the diagnosis of ATTR cardiac amyloidosis: Comparison of quantitative and semi-quantitative approaches
    Regis, Claudine
    Harel, Francois
    Martineau, Patrick
    Gregoire, Jean
    Abikhzer, Gad
    Juneau, Daniel
    Pelletier-Galarneau, Matthieu
    JOURNAL OF NUCLEAR CARDIOLOGY, 2020, 27 (05) : 1808 - 1815
  • [10] National patterns in imaging utilization for diagnosis of cardiac amyloidosis: A focus on Tc99m-pyrophosphate scintigraphy
    Harb, Serge C.
    Haq, Muhammad
    Flood, Kathleen
    Guerrieri, Angela
    Passerell, Wendy
    Jaber, Wael A.
    Miller, Edward J.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2017, 24 (03) : 1094 - 1097