Biomechanical Properties of Repair Cartilage Tissue Are Superior Following Microdrilling Compared to Microfracturing in Critical Size Cartilage Defects

被引:3
作者
Pohlig, Florian [1 ]
Wittek, Michael [2 ]
Von Thaden, Anne [3 ]
Lenze, Ulrich [1 ]
Glowalla, Claudio [1 ,2 ]
Minzlaff, Philipp [4 ]
Burgkart, Rainer [1 ]
Prodinger, Peter Michael [3 ,4 ]
机构
[1] Tech Univ Munich TUM, Dept Orthopaed Surg, Klinikum Rechts Isar, Ismaninger Str 22, D-81675 Munich, Germany
[2] BG Unfallklin Murnau, Murnau, Germany
[3] German Ctr Neurodegenerat Dis, Munich, Germany
[4] Krankenhaus Agatharied, Dept Orthopaed Surg & Traumatol, Hausham, Germany
来源
IN VIVO | 2023年 / 37卷 / 02期
关键词
Knee; cartilage; microfracturing; drilling; regeneration; defect; focal chondral defect; FCD; MFX; DRL; BONE-MARROW STIMULATION; ARTICULAR-CARTILAGE; CHONDRAL DEFECTS; KNEE; LESIONS; MATRIX;
D O I
10.21873/invivo.13115
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background/Aim: Common surgical treatment options for large focal chondral defects (FCDs) in the knee include microfracturing (MFX) and microdrilling (DRL). Despite numerous studies addressing MFX and DRL of FDCs, no in vivo study has focused on biomechanical analysis of repair cartilage tissue in critical size FCDs with different amounts of holes and penetration depths. Materials and methods: Two round FCDs (d=6 mm) were created on the medial femoral condyle in 33 adult merino sheep. All 66 defects were randomly assigned to 1 control or 4 different study groups: 1) MFX1, 3 holes, 2 mm depth; 2) MFX2, 3 holes, 4 mm depth; 3) DRL1, 3 holes, 4 mm depth; and 4) DRL2, 6 holes, 4 mm depth. Animals were followed up for 1 year. Following euthanasia, quantitative optical analysis of defect filling was performed. Biomechanical properties were analysed with microindentation and calculation of the elastic modulus. Results: Quantitative assessment of defect filling showed significantly better results in all treatment groups compared to untreated FCDs in the control group (p<0.001), with the best results for DRL2 (84.2% filling). The elastic modulus of repair cartilage tissue in the DRL1 and DRL2 groups was comparable to the adjacent native hyaline cartilage, while significantly inferior results were identified in both MFX groups (MFX1: p=0.002; MFX2: p<0.001). Conclusion: More defect filling and better biomechanical properties of the repair cartilage tissue were identified for DRL compared to MFX, with the best results for 6 holes and 4 mm of penetration depth. These findings are in contrast to the current clinical practice with MFX as the gold standard and suggest a clinical return to DRL.
引用
收藏
页码:565 / 573
页数:9
相关论文
共 50 条
  • [31] Depth-dependent biomechanical and biochemical properties of fetal, newborn, and tissue-engineered articular cartilage
    Klein, Travis J.
    Chaudhry, Manu
    Bae, Won C.
    Sah, Robert L.
    JOURNAL OF BIOMECHANICS, 2007, 40 (01) : 182 - 190
  • [32] Relationship between physical, biochemical and biomechanical properties of tissue-engineered cartilage-carrier-constructs
    Nagel-Heyer, S
    Goepfert, C
    Morlock, M
    Pörtner, R
    BIOTECHNOLOGY LETTERS, 2005, 27 (03) : 187 - 192
  • [33] Relationship between physical, biochemical and biomechanical properties of tissue-engineered cartilage-carrier-constructs
    Stephanie Nagel-Heyer
    Christiane Goepfert
    Michael M. Morlock
    Ralf Pörtner
    Biotechnology Letters, 2005, 27 : 187 - 192
  • [34] Repair of bone defects in vivo using tissue engineered hypertrophic cartilage grafts produced from nasal chondrocytes
    Bardsley, Katie
    Kwarciak, Agnieska
    Freeman, Christine
    Brook, Ian
    Hatton, Paul
    Crawford, Aileen
    BIOMATERIALS, 2017, 112 : 313 - 323
  • [35] Glycosaminoglycan profiles of repair tissue formed following autologous chondrocyte implantation differ from control cartilage
    Aarti Sharma
    Lindsay D Wood
    James B Richardson
    Sally Roberts
    Nicola J Kuiper
    Arthritis Research & Therapy, 9
  • [36] The effect of tissue-engineered cartilage biomechanical and biochemical properties on its post-implantation mechanical behavior
    Khoshgoftar, Mehdi
    Wilson, Wouter
    Ito, Keita
    van Donkelaar, Corrinus C.
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2013, 12 (01) : 43 - 54
  • [37] Evaluation of Negative Fixed-Charge Density in Tissue-Engineered Cartilage by Quantitative MRI and Relationship With Biomechanical Properties
    Miyata, Shogo
    Homma, Kazuhiro
    Numano, Tomokazu
    Tateishi, Tetsuya
    Ushida, Takashi
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2010, 132 (07):
  • [38] Relationships between structural stability of implanted site and biomechanical properties of tissue-engineered cartilage in the tibiofemoral joint defect
    Lee, Gang To
    Park, Sang-Hyug
    Min, Byoung-Hyun
    Bae, Tae Soo
    TISSUE ENGINEERING AND REGENERATIVE MEDICINE, 2015, 12 : 105 - 112
  • [39] Novel Scaffold-Based BST-CarGel Treatment Results in Superior Cartilage Repair Compared with Microfracture in a Randomized Controlled Trial
    Stanish, William D.
    McCormack, Robert
    Forriol, Francisco
    Mohtadi, Nicholas
    Pelet, Stephane
    Desnoyers, Jacques
    Restrepo, Alberto
    Shive, Matthew S.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2013, 95A (18) : 1640 - 1650
  • [40] A three-dimensional reconstruction of tissue engineered cartilage with electrospun fibrous scaffolds of poly(lactic-co-glycolic acid) for the repair of full-thickness defects of articular cartilage
    Zhang, Hong-Mei
    Chen, Yu-Bing
    Zhang, Pei-Biao
    Wu, Han
    MINERVA BIOTECNOLOGICA, 2017, 29 (03) : 114 - 125