Fiber-optic lead ion sensor based on MXene film integrated michelson interference structure

被引:7
作者
Xiong, Guo Liang [1 ]
Zhuang, Jing Hao [1 ]
Feng, Wen Lin [1 ,2 ]
机构
[1] Chongqing Univ Technol, Dept Phys & Energy, Chongqing 400054, Peoples R China
[2] Chongqing Key Lab Green Energy Mat Technol & Syst, Chongqing 400054, Peoples R China
基金
中国国家自然科学基金;
关键词
Ti(3)C(2)Tx (MXene); fiber-optic sensing; michelson interference; lead ion;
D O I
10.1088/1402-4896/acb301
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Ti3C2Tx (MXene), a two-dimensional material prepared by solution etching, has abundant functional groups on its surface, which makes it have a great prospect in the field of biosensing environmental detection. In this work, a new optical fiber sensor integrated with MXene is proposed and fabricated. The sensor is constituted of a three-core fiber (TCF), a single-mode fiber (SMF), and a no-core fiber (NCF) to form a Michelson interference structure. The results indicate that MXene decorated fiber-optic sensor can detect trace lead ions (Pb2+) and has a good response to the Pb2+ solutions with the concentration of 0-100 mu M. At 0.001 mu M (i.e., 0.286 ppb) Pb2+, the response time is about 2 min. In addition, the fiber-optic sensor has excellent temperature, pH, and time stability. The present work provides a new idea for the detection of Pb2+ in heavy metal pollution fields.
引用
收藏
页数:12
相关论文
共 46 条
  • [1] An optical fiber based surface plasmon resonance technique for sensing of lead ions: A toxic water pollutant
    Boruah, Bijoy Sankar
    Biswas, Rajib
    [J]. OPTICAL FIBER TECHNOLOGY, 2018, 46 : 152 - 156
  • [2] Glucose Sensor Using U-Shaped Optical Fiber Probe with Gold Nanoparticles and Glucose Oxidase
    Chen, Kuan-Chieh
    Li, Yu-Le
    Wu, Chao-Wei
    Chiang, Chia-Chin
    [J]. SENSORS, 2018, 18 (04)
  • [3] Refractive Index Sensors Based on Ti3C2Tx MXene Fibers
    Chen, Yuzhi
    Ge, Yanqi
    Huang, Weichun
    Li, Zhongjun
    Wu, Leiming
    Zhang, Han
    Li, Xuejin
    [J]. ACS APPLIED NANO MATERIALS, 2020, 3 (01) : 303 - 311
  • [4] Intracellular Pb2+ Content Monitoring Using a Protein-Based Pb2+ Indicator
    Chiu, Tai-Yu
    Yang, De-Ming
    [J]. TOXICOLOGICAL SCIENCES, 2012, 126 (02) : 436 - 445
  • [5] Determination of lead by flow injection hydride generation atomic absorption spectrometry with tetrahydroborate immobilized on an anion-exchange resin
    Chuachuad, W
    Tyson, JF
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2005, 20 (04) : 282 - 288
  • [6] Mxene/alginate composites for lead and copper ion removal from aqueous solutions
    Dong, Yanjie
    Sang, Dashen
    He, Chengdong
    Sheng, Xinfeng
    Lei, Longwen
    [J]. RSC ADVANCES, 2019, 9 (50) : 29015 - 29022
  • [7] Utilization of Chitosan-Based Sensor Thin Films for the Detection of Lead Ion by Surface Plasmon Resonance Optical Sensor
    Fen, Yap Wing
    Yunus, W. Mahmood Mat
    [J]. IEEE SENSORS JOURNAL, 2013, 13 (05) : 1413 - 1418
  • [8] Biomimetic Sensing System for Tracing Pb2+ Distribution in Living Cells Based on the Metal-Peptide Supramolecular Assembly
    Gui, Shilang
    Huang, Yanyan
    Zhu, Yuanyuan
    Jin, Yulong
    Zhao, Rui
    [J]. ACS APPLIED MATERIALS & INTERFACES, 2019, 11 (06) : 5804 - 5811
  • [9] A Disposable Optical Fiber-Based Capillary Probe for Sensing Lead Ions
    Guillemain, Henri
    Rajarajan, Muttukrishnan
    Sun, Tong
    Grattan, Kenneth T. V.
    Lin, Yu-Chen
    Chen, Chao-Tsen
    [J]. IEEE SENSORS JOURNAL, 2008, 8 (9-10) : 1656 - 1662
  • [10] X-ray photoelectron spectroscopy of select multi-layered transition metal carbides (MXenes)
    Halim, Joseph
    Cook, Kevin M.
    Naguib, Michael
    Eklund, Per
    Gogotsi, Yury
    Rosen, Johanna
    Barsoum, Michel W.
    [J]. APPLIED SURFACE SCIENCE, 2016, 362 : 406 - 417