Custom-made 3D-printed porous metal acetabular composite component in revision hip arthroplasty with Paprosky type III acetabular defects: A case report

被引:5
作者
Xiao, Cong [1 ]
Zhang, Shaoyun [1 ,2 ]
Gao, Zhixiang [1 ]
Tu, Chongqi [2 ]
机构
[1] Sichuan Mental Hlth Ctr, Hosp Mianyang 3, Dept Orthoped, Mianyang, Sichuan, Peoples R China
[2] Sichuan Univ, West China Hosp, Dept Orthoped, 37 Guoxue Rd, Chengdu 610041, Sichuan, Peoples R China
关键词
Revision hip arthroplasty; acetabular defects; 3D printing; porous titanium; composite component; custom-made; case report; JUMBO CUPS; RECONSTRUCTION; EPIDEMIOLOGY;
D O I
10.3233/THC-212984
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
BACKGROUND: Increases in the numbers of surgical procedures for primary total hip arthroplasty (THA) inevitably lead to increases in the requirements for revision THA. The achievement of long-term stability is difficult or impossible by conventional implants in patients with severe destruction of the acetabulum. OBJECTIVE: This case report presents a successful treatment using a specific three-dimensional (3D)-printed porous titanium acetabular composite component without a flange in the management of Paprosky type IIIB acetabular defects. METHOD: A 65-year-old female diagnosed with right hip prosthetic loosening with a huge acetabular defect presented to our hospital. We designed the 3D model of the pelvis and created an individualized 3D-printed porous titanium acetabular composite component for revision THA. The procedure was performed through a posterolateral approach, and the component was implanted in the defect and fixed with cup screws using the drill guides. RESULTS: At the last follow-up at 2 years, the patient had a satisfactory hip joint function and no signs of loosening or other complications were found. CONCLUSIONS: The 3D-printed porous titanium acetabular composite component without a flange is showing promising clinical and radiological outcomes in the management of Paprosky type III acetabular defects.
引用
收藏
页码:283 / 291
页数:9
相关论文
共 20 条
[11]   Revision of Complex Acetabular Defects Using Cages with the Aid of Rapid Prototyping [J].
Li, Huiwu ;
Wang, Liao ;
Mao, Yuanqing ;
Wang, You ;
Dai, Kerong ;
Zhu, Zhenan .
JOURNAL OF ARTHROPLASTY, 2013, 28 (10) :1770-1775
[12]   A three-dimensional printed porous implant combined with bone grafting following curettage of a subchondral giant cell tumour of the proximal tibia: a case report [J].
Lu, Minxun ;
Wang, Jie ;
Tang, Fan ;
Min, Li ;
Zhou, Yong ;
Zhang, Wenli ;
Tu, Chongqi .
BMC SURGERY, 2019, 19 (1)
[13]   Characterization of cellular solids in Ti6Al4V for orthopaedic implant applications: Trabecular titanium [J].
Marin, E. ;
Fusi, S. ;
Pressacco, M. ;
Paussa, L. ;
Fearizzi, L. .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2010, 3 (05) :373-381
[14]   Do Jumbo Cups Cause Hip Center Elevation in Revision THA? A Computer Simulation [J].
Nwankwo, Chima ;
Dong, Nick N. ;
Heffernan, Christopher D. ;
Ries, Michael D. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2014, 472 (02) :572-576
[15]  
Paprosky W G, 1994, J Arthroplasty, V9, P33, DOI 10.1016/0883-5403(94)90135-X
[16]   The epidemiology of revision total knee and hip arthroplasty in England and Wales A COMPARATIVE ANALYSIS WITH PROJECTIONS FOR THE UNITED STATES. A STUDY USING THE NATIONAL JOINT REGISTRY DATASET [J].
Patel, A. ;
Pavlou, G. ;
Mujica-Mota, R. E. ;
Toms, A. D. .
BONE & JOINT JOURNAL, 2015, 97B (08) :1076-1081
[17]   The Emerging Role of 3D Printing in Arthroplasty and Orthopedics [J].
Trauner, Kenneth B. .
JOURNAL OF ARTHROPLASTY, 2018, 33 (08) :2352-2354
[18]   Evaluation of a porous tantalum uncemented acetabular cup in revision total hip arthroplasty - Clinical and radiological results of 60 hips [J].
Unger, AS ;
Lewis, RJ ;
Gruen, T .
JOURNAL OF ARTHROPLASTY, 2005, 20 (08) :1002-1009
[19]   Monoflanged Custom-Made Acetabular Components Promote Biomechanical Restoration of Severe Acetabular Bone Defects by Metallic Defect Reconstruction [J].
Walter, Sebastian G. ;
Randau, Thomas M. ;
Gravius, Nadine ;
Gravius, Sascha ;
Froeschen, Frank S. .
JOURNAL OF ARTHROPLASTY, 2020, 35 (03) :831-835
[20]   The Utilization of Metal Augments Allows Better Biomechanical Reconstruction of the Hip in Revision Total Hip Arthroplasty With Severe Acetabular Defects: A Comparative Study [J].
Zhou, Baochun ;
Zhou, Yixin ;
Yang, Dejin ;
Tang, Hao ;
Shao, Hongyi ;
Huang, Yong .
JOURNAL OF ARTHROPLASTY, 2018, 33 (12) :3724-3733