Clogging and rehabilitation performance of pervious concrete

被引:2
作者
Nazeer, Mudasir [1 ]
Kapoor, Kanish [1 ]
Singh, S. P. [1 ,2 ]
机构
[1] Dr BR Ambedkar Natl Inst Technol, Dept Civil Engn, Jalandhar, India
[2] Dr BR Ambedkar Natl Inst Technol, Dept Civil Engn, Jalandhar 144011, India
关键词
pervious concrete; compressive strength; aggregates grade proportion; permeability; artificial clogging; UN SDG 11; Sustainable cities and communities; UN SDG 13; Climate action; PERMEABLE CONCRETE; DESIGN; AGGREGATE;
D O I
10.1680/jcoma.22.00099
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The performance of pervious concrete was observed for different cloggers like Sand (S), Clay (C) and their combination (S & C). The clogging potential of pervious concrete was determined by simulating natural clogging conditions on cylindrical specimens with a sediment load of 50, 150, and 200 grammes for S, C, and combined S & C laden runoff cycles, respectively. Furthermore, this study was extended to observe the recovery rate of infiltration using rehabilitation techniques such as vacuuming (V), Pressure Washing (P) and Vacuuming Followed by Pressure Washing (VP). It was observed from the results that combined (S & C) clogger shows overall critical results of clogging as 80% of the clogging was seen in 3 to 4 cycles. However, cloggers S and C shows 80% of clogging after 7 and 8 cycles. Moreover, among rehabilitation techniques, V shows average recovery rate of 52%, 75% and 76% for C, S and S & C cloggers. An average recovery rate of 63%, 71%, and 71% was seen for C, S and S & C cloggers on applying P technique. However, VP shows a maximum recovery rate of 78%, 77% and 64% against C, S and S & C cloggers.
引用
收藏
页码:159 / 176
页数:18
相关论文
共 37 条
  • [1] ACI, 2010, 522R-10
  • [2] [Anonymous], 2016, IS: 2386, P1
  • [3] [Anonymous], 2012, ASTM D698: Standard Test Methods for Laboratory Compaction Characteristics of Soil Using Standard Effort (12 400 ft-lbf/ft3 (600 kN-m/m3)), P3, DOI DOI 10.1520/C1754
  • [4] [Anonymous], 2016, STANDARD TEST METHOD, P1, DOI 10.1520/D1857-17.2
  • [5] ASTM International, 2001, C1437 ASTM, P1, DOI DOI 10.1520/C0127-12.1
  • [6] Material characterization and hydraulic conductivity modeling of macroporous recycled-aggregate pervious concrete
    Barnhouse, Patrick W.
    Srubar, Wil V., III
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2016, 110 : 89 - 97
  • [7] Bureau of Indian Standard(BIS), 2013, IS: 8112-1989, Specification for 43 Grade Ordinary Portland Cement, P17
  • [8] Bureau of Indian Standards, 2002, IS: 2720 (part 16). Method of test for soils, P1
  • [9] Infiltration and Clogging by Sand and Clay in a Pervious Concrete Pavement System
    Coughlin, J. Patrick
    Campbell, Chelsea D.
    Mays, David C.
    [J]. JOURNAL OF HYDROLOGIC ENGINEERING, 2012, 17 (01) : 68 - 73
  • [10] A modified method for the design of pervious concrete mix
    Dang Hanh Nguyen
    Sebaibi, Nassim
    Boutouil, Mohamed
    Leleyter, Lydia
    Baraud, Fabienne
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2014, 73 : 271 - 282