Image quality of spectral brain computed tomography angiography using halved dose of iodine contrast medium

被引:2
|
作者
Fransson, Veronica [1 ,2 ]
Mellander, Helena [3 ,4 ]
Ramgren, Birgitta [3 ,4 ]
Andersson, Henrik [3 ,4 ]
Arena, Francesco [3 ]
Ydstroem, Kristina [1 ,5 ]
Ullberg, Teresa [6 ]
Wasselius, Johan [3 ,4 ]
机构
[1] Skane Univ Hosp, Dept Hematol Oncol & Radiat Phys, Radiat Phys, Lund, Sweden
[2] Lund Univ, Dept Translat Med, Med Radiat Phys, Malmo, Sweden
[3] Skane Univ Hosp, Dept Med Imaging & Physiol, S-22185 Lund, Sweden
[4] Lund Univ, Dept Clin Sci, Lund, Sweden
[5] Lund Univ, Dept Clin Sci, Med Radiat Phys, Lund, Sweden
[6] Lund Univ, Skane Univ Hosp, Dept Clin Sci Lund, Neurol, Lund, Sweden
关键词
Computed tomography angiography; Contrast material reduction; Dual-energy CT; Spectral CT; Virtual monoenergetic images; Contrast-induced nephropathy; DUAL-ENERGY CT; VGC ANALYZER; ROC SOFTWARE; TUBE-VOLTAGE; REDUCTION; FREQUENCY; VIEWDEX; KIDNEY; LOAD; TOOL;
D O I
10.1007/s00234-023-03190-1
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
PurposeReduction in iodinated contrast medium (CM) dose is highly motivated. Our aim was to evaluate if a 50% reduction of CM, while preserving image quality, is possible in brain CT angiography (CTA) using virtual monoenergetic images (VMI) on spectral CT. As a secondary aim, we evaluated if VMI can salvage examinations with suboptimal CM timing.MethodsConsecutive patients older than 18 years without intracranial stenosis/occlusion were included. Three imaging protocols were used: group 1, full CM dose; group 2, 50% CM dose suboptimal timing; and group 3, 50% CM dose optimized timing.Attenuation, noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured in the internal carotid artery, M2 segment of the middle cerebral artery, and white matter for conventional images (CI) and VMI (40-200 keV). Qualitative image quality for CI and VMI (50 and 60 keV) was rated by 4 experienced reviewers.ResultsQualitatively and quantitatively, VMI (40-60 keV) improved image quality within each group. Significantly higher attenuation and CNR was found for group 3 VMI 40-50 keV, with unchanged SNR, compared to group 1 CI. Group 3 VMI 50 keV also received significantly higher rating scores than group 1 CI. Group 2 VMI (40-50 keV) had significantly higher CNR compared to group 3 CI, but the subjective image quality was similar.ConclusionVMI of 50 keV with 50% CM dose increases qualitative and quantitative image quality over CI with full CM dose. Using VMI reduces non-diagnostic examinations and may salvage CTA examinations deemed non-diagnostic due to suboptimal timing.
引用
收藏
页码:1333 / 1342
页数:10
相关论文
共 50 条
  • [41] Monochromatic image reconstruction by dual energy imaging allows half iodine load computed tomography coronary angiography
    Carrascosa, Patricia
    Leipsic, Jonathon A.
    Capunay, Carlos
    Deviggiano, Alejandro
    Vallejos, Javier
    Goldsmit, Alejandro
    Rodriguez-Granillo, Gaston A.
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (10) : 1915 - 1920
  • [42] Dual-Energy Computed Tomography: Is There a Penalty in Image Quality and Radiation Dose Compared With Single-Energy Computed Tomography?
    Thomas, Christoph
    Ketelsen, Dominik
    Tsiflikas, Ilias
    Reimann, Anja
    Brodoefel, Harald
    Claussen, Claus D.
    Heuschmid, Martin
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2010, 34 (02) : 309 - 315
  • [43] Cerebral computed tomographic angiography using third-generation reconstruction algorithm provides improved image quality with lower contrast and radiation dose
    Bathla, Girish
    Priya, Sarv
    Samaniego, Edgar
    Deo, Simmi K.
    Fain, Nicholas H.
    Soni, Neetu
    Ward, Caitlin
    Derdeyn, Colin P.
    NEURORADIOLOGY, 2020, 62 (08) : 965 - 970
  • [44] A randomised controlled trial comparing three clinical administration strategies in spectral detector CT pulmonary angiography with low contrast medium dose
    Kristiansen, Cathrine Helgestad
    Thomas, Owen
    Nyquist, Anton Bengt
    Sanderud, Audun
    Boavida, Joao
    Geitung, Jonn Terje
    Tran, Thien Trung
    Lauritzen, Peter Maehre
    EUROPEAN RADIOLOGY, 2025,
  • [45] Impact of left atrial enlargement on image quality in coronary computed tomography angiography
    Nguyen, Tien C.
    Ohyama, Yoshiaki
    Taketomi-Takahashi, Ayako
    Nguyen, Huong T.
    Sumiyoshi, Hisako
    Nakamura, Tetsuya
    Kurabayashi, Masahiko
    Tsushima, Yoshito
    CLINICAL IMAGING, 2022, 84 : 87 - 92
  • [46] Optimization of hybrid iterative reconstruction level and evaluation of image quality and radiation dose for pediatric cardiac computed tomography angiography
    Yang, Lin
    Zhuang, Jian
    Huang, Meiping
    Liang, Changhong
    Liu, Hui
    PEDIATRIC RADIOLOGY, 2017, 47 (01) : 31 - 38
  • [47] Computed tomography pulmonary angiograms using a novel dual-layer spectral detector Adjusted window settings are essential for diagnostic image quality
    Iuga, Andra-Iza
    Doerner, Jonas
    Siedek, Florian
    Haneder, Stefan
    Byrtus, Jonathan
    Luetkens, Julian A.
    Maintz, David
    Hickethier, Tilman
    MEDICINE, 2019, 98 (33)
  • [48] Radiation Dose and Image Noise Evaluation in Coronary Computed Tomography Angiography (CCTA) Using an Iterative Reconstruction Algorithm
    Kordolaimi, Sofia D.
    Argentos, Stylianos
    Stathis, George
    Alexiou, Antigoni
    Pantos, Ioannis
    Katritsis, Demosthenes G.
    Kelekis, Nikolaos L.
    Seimenis, Ioannis
    Efstathopoulos, Efstathios P.
    HELLENIC JOURNAL OF CARDIOLOGY, 2014, 55 (03) : 184 - 190
  • [49] Development of a computed tomography phantom to evaluate radiation dose and image quality
    Gomez Cardona, Daniel
    Estrada Leon, Edgar Santiago
    Zuluaga Santamaria, Alejandro
    Benitez, Luis
    Ramirez Giraldo, Juan Carlos
    2013 PAN AMERICAN HEALTH CARE EXCHANGES (PAHCE), 2013,
  • [50] Halved contrast medium dose coronary dual-layer CT-angiography - phantom study of tube current and patient characteristics
    Kristiansen, C. H.
    Tetteroo, P. M.
    Dobrolinska, M. M.
    Lauritzen, P. M.
    Velthuis, B. K.
    Greuter, M. J. W.
    Sucha, D.
    de Jong, P. A.
    van der Werf, N. R.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2024, 40 (04): : 931 - 940