Image quality of spectral brain computed tomography angiography using halved dose of iodine contrast medium

被引:2
|
作者
Fransson, Veronica [1 ,2 ]
Mellander, Helena [3 ,4 ]
Ramgren, Birgitta [3 ,4 ]
Andersson, Henrik [3 ,4 ]
Arena, Francesco [3 ]
Ydstroem, Kristina [1 ,5 ]
Ullberg, Teresa [6 ]
Wasselius, Johan [3 ,4 ]
机构
[1] Skane Univ Hosp, Dept Hematol Oncol & Radiat Phys, Radiat Phys, Lund, Sweden
[2] Lund Univ, Dept Translat Med, Med Radiat Phys, Malmo, Sweden
[3] Skane Univ Hosp, Dept Med Imaging & Physiol, S-22185 Lund, Sweden
[4] Lund Univ, Dept Clin Sci, Lund, Sweden
[5] Lund Univ, Dept Clin Sci, Med Radiat Phys, Lund, Sweden
[6] Lund Univ, Skane Univ Hosp, Dept Clin Sci Lund, Neurol, Lund, Sweden
关键词
Computed tomography angiography; Contrast material reduction; Dual-energy CT; Spectral CT; Virtual monoenergetic images; Contrast-induced nephropathy; DUAL-ENERGY CT; VGC ANALYZER; ROC SOFTWARE; TUBE-VOLTAGE; REDUCTION; FREQUENCY; VIEWDEX; KIDNEY; LOAD; TOOL;
D O I
10.1007/s00234-023-03190-1
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
PurposeReduction in iodinated contrast medium (CM) dose is highly motivated. Our aim was to evaluate if a 50% reduction of CM, while preserving image quality, is possible in brain CT angiography (CTA) using virtual monoenergetic images (VMI) on spectral CT. As a secondary aim, we evaluated if VMI can salvage examinations with suboptimal CM timing.MethodsConsecutive patients older than 18 years without intracranial stenosis/occlusion were included. Three imaging protocols were used: group 1, full CM dose; group 2, 50% CM dose suboptimal timing; and group 3, 50% CM dose optimized timing.Attenuation, noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured in the internal carotid artery, M2 segment of the middle cerebral artery, and white matter for conventional images (CI) and VMI (40-200 keV). Qualitative image quality for CI and VMI (50 and 60 keV) was rated by 4 experienced reviewers.ResultsQualitatively and quantitatively, VMI (40-60 keV) improved image quality within each group. Significantly higher attenuation and CNR was found for group 3 VMI 40-50 keV, with unchanged SNR, compared to group 1 CI. Group 3 VMI 50 keV also received significantly higher rating scores than group 1 CI. Group 2 VMI (40-50 keV) had significantly higher CNR compared to group 3 CI, but the subjective image quality was similar.ConclusionVMI of 50 keV with 50% CM dose increases qualitative and quantitative image quality over CI with full CM dose. Using VMI reduces non-diagnostic examinations and may salvage CTA examinations deemed non-diagnostic due to suboptimal timing.
引用
收藏
页码:1333 / 1342
页数:10
相关论文
共 50 条
  • [31] Comparison of radiation dose and image quality between flat panel computed tomography and multidetector computed tomography in a hybrid CT-angiography suite
    Jones, Aaron K.
    Odisio, Bruno C.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (02): : 121 - 127
  • [32] Computed Tomography Angiography Combined With Knowledge-Based Iterative Algorithm for Transcatheter Aortic Valve Implantation Planning: Image Quality and Radiation Dose Exposure With Low-kV and Low-Contrast-Medium Protocol
    Ippolito, Davide
    Riva, Luca
    Franzesi, Cammillo Talei
    De Vito, Andrea
    Cangiotti, Cecilia
    Crespi, Andrea
    Corso, Rocco
    Sironi, Sandro
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2020, 44 (01) : 13 - 19
  • [33] Feasibility of Reduced Radiation Dose and Iodine Load in Lower Extremity Computed Tomography Angiography
    Park, J. W.
    Kim, S. S.
    Lee, J. H.
    Park, J. H.
    HONG KONG JOURNAL OF RADIOLOGY, 2019, 22 (03): : 172 - 179
  • [34] Impact of 80 kVp with iterative reconstruction algorithm and low-dose contrast medium on the image quality of craniocervical CT angiography
    Chen, Po-An
    Chen, Chih-Wei
    Chou, Chiung-Chen
    Fu, Jui-Hsun
    Wang, Po-Chin
    Hsu, Shuo-Hsiu
    Lai, Ping-Hong
    CLINICAL IMAGING, 2020, 68 (68) : 124 - 130
  • [35] Low tube voltage computed tomography urography using low-concentration contrast media: Comparison of image quality in conventional computed tomography urography
    Hwang, Inpyeong
    Cho, Jeong Yeon
    Kim, Sang Youn
    Oh, Seung-June
    Ku, Ja Hyeon
    Lee, Joongyup
    Kim, Seung Hyup
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (12) : 2454 - 2463
  • [36] Application of Artificial Intelligence-based Image Optimization for Computed Tomography Angiography of the Aorta With Low Tube Voltage and Reduced Contrast Medium Volume
    Wang, Yining
    Yu, Min
    Wang, Ming
    Wang, Yun
    Kong, Lingyan
    Yi, Yan
    Wang, Man
    Li, Yumei
    Jin, Zhengyu
    JOURNAL OF THORACIC IMAGING, 2019, 34 (06) : 393 - 399
  • [37] Influence of cardiac function on image quality in coronary computed tomography angiography
    Nguyen, Tien C.
    Ohyama, Yoshiaki
    Taketomi-Takahashi, Ayako
    Nguyen, Huong T.
    Sugimoto, Akio
    Sato, Makito
    Sumiyoshi, Hisako
    Nakamura, Tetsuya
    Kurabayashi, Masahiko
    Tsushima, Yoshito
    CLINICAL IMAGING, 2019, 53 : 58 - 64
  • [38] Low-dose CT angiography of the abdominal aorta and reduced contrast medium volume: Assessment of image quality and radiation dose
    Nijhof, W. H.
    Baltussen, E. J. M.
    Kant, I. M. J.
    Jager, G. J.
    Slump, C. H.
    Rutten, M. J. C. M.
    CLINICAL RADIOLOGY, 2016, 71 (01) : 64 - 73
  • [39] Radiation Dose and Image Quality in Adult Computed Tomography Scans
    Al Ewaidat, Haytham
    Zheng, Xiaoming
    Khader, Yousef
    Theeb, Mostafa Abdelrahman
    Alhasan, Mostafa Khaled Mustafa
    Rawashdeh, Mohammad Ahmmad
    Al Mousa, Dana Samir
    Alawneh, Khaled Zayed Ali
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2018, 8 (02) : 223 - 231
  • [40] Coronary CT angiography by modifying tube voltage and contrast medium concentration: Evaluation of image quality and radiation dose
    Gazafroudi, Seyede Shokoofeh Mousavi
    Tavakkoli, Mohammad Bagher
    Moradi, Maryam
    Gazafroudi, Seyede Shabnam Mousavi
    Yadegarfar, Ghasem
    Behjati, Mohaddeseh
    Karimian, Mohammad
    Khajouei, Amirreza Sajjadieh
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2019, 36 (07): : 1391 - 1396