Image quality of spectral brain computed tomography angiography using halved dose of iodine contrast medium

被引:2
|
作者
Fransson, Veronica [1 ,2 ]
Mellander, Helena [3 ,4 ]
Ramgren, Birgitta [3 ,4 ]
Andersson, Henrik [3 ,4 ]
Arena, Francesco [3 ]
Ydstroem, Kristina [1 ,5 ]
Ullberg, Teresa [6 ]
Wasselius, Johan [3 ,4 ]
机构
[1] Skane Univ Hosp, Dept Hematol Oncol & Radiat Phys, Radiat Phys, Lund, Sweden
[2] Lund Univ, Dept Translat Med, Med Radiat Phys, Malmo, Sweden
[3] Skane Univ Hosp, Dept Med Imaging & Physiol, S-22185 Lund, Sweden
[4] Lund Univ, Dept Clin Sci, Lund, Sweden
[5] Lund Univ, Dept Clin Sci, Med Radiat Phys, Lund, Sweden
[6] Lund Univ, Skane Univ Hosp, Dept Clin Sci Lund, Neurol, Lund, Sweden
关键词
Computed tomography angiography; Contrast material reduction; Dual-energy CT; Spectral CT; Virtual monoenergetic images; Contrast-induced nephropathy; DUAL-ENERGY CT; VGC ANALYZER; ROC SOFTWARE; TUBE-VOLTAGE; REDUCTION; FREQUENCY; VIEWDEX; KIDNEY; LOAD; TOOL;
D O I
10.1007/s00234-023-03190-1
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
PurposeReduction in iodinated contrast medium (CM) dose is highly motivated. Our aim was to evaluate if a 50% reduction of CM, while preserving image quality, is possible in brain CT angiography (CTA) using virtual monoenergetic images (VMI) on spectral CT. As a secondary aim, we evaluated if VMI can salvage examinations with suboptimal CM timing.MethodsConsecutive patients older than 18 years without intracranial stenosis/occlusion were included. Three imaging protocols were used: group 1, full CM dose; group 2, 50% CM dose suboptimal timing; and group 3, 50% CM dose optimized timing.Attenuation, noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured in the internal carotid artery, M2 segment of the middle cerebral artery, and white matter for conventional images (CI) and VMI (40-200 keV). Qualitative image quality for CI and VMI (50 and 60 keV) was rated by 4 experienced reviewers.ResultsQualitatively and quantitatively, VMI (40-60 keV) improved image quality within each group. Significantly higher attenuation and CNR was found for group 3 VMI 40-50 keV, with unchanged SNR, compared to group 1 CI. Group 3 VMI 50 keV also received significantly higher rating scores than group 1 CI. Group 2 VMI (40-50 keV) had significantly higher CNR compared to group 3 CI, but the subjective image quality was similar.ConclusionVMI of 50 keV with 50% CM dose increases qualitative and quantitative image quality over CI with full CM dose. Using VMI reduces non-diagnostic examinations and may salvage CTA examinations deemed non-diagnostic due to suboptimal timing.
引用
收藏
页码:1333 / 1342
页数:10
相关论文
共 50 条
  • [21] Assessment of Radiation Dose and Image Quality of Multidetector Computed Tomography
    Al Ewaidat, Haytham
    Zheng, Xiaoming
    Khader, Yousef
    Abdelrahman, Mostafa
    Alhasan, Mostafa Khaled Mustafa
    Rawashdeh, Mohammad Ahmmad
    Al Mousa, Dana Samir
    Alawneh, Khaled Zayed Ali
    IRANIAN JOURNAL OF RADIOLOGY, 2018, 15 (03)
  • [22] Image quality, contrast enhancement and radiation dose of electrocardiograph- versus non-electrocardiograph-triggered computed tomography angiography of the aorta
    Wong, Ying Mei
    Ong, Ching Ching
    Liang, Chong Ri
    Tan, Choon Ann
    Teo, Lynette Li San
    SINGAPORE MEDICAL JOURNAL, 2024, 65 (02) : 84 - 90
  • [23] Quantifying image quality in chest computed tomography angiography: Evaluation of different contrast-to-noise ratio measurement methods
    Chatzaraki, Vasiliki
    Kubik-Huch, Rahel A.
    Thali, Michael
    Niemann, Tilo
    ACTA RADIOLOGICA, 2022, 63 (10) : 1353 - 1362
  • [24] Image quality and required radiation dose for coronary computed tomography angiography using an automatic tube potential selection technique
    Wang, Ying
    Wang, Xiaohua
    Zhang, Yan
    Lu, Yuliu
    Wu, Runze
    Yuan, Huishu
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 : 89 - 94
  • [25] Cerebral computed tomography angiography using a 70 kVp protocol: improved vascular enhancement with a reduced volume of contrast medium and radiation dose
    Eun-Suk Cho
    Tae-Sub Chung
    Sung Jun Ahn
    KyoungHoon Chong
    Jang Hun Baek
    Sang Hyun Suh
    European Radiology, 2015, 25 : 1421 - 1430
  • [26] 80-kVp CT angiography for endovascular aneurysm repair follow-up with halved contrast medium dose and preserved diagnostic quality
    Lehti, Leena
    Nyman, Ulf
    Soderberg, Marcus
    Bjorses, Katarina
    Gottsater, Anders
    Wasselius, Johan
    ACTA RADIOLOGICA, 2016, 57 (03) : 279 - 286
  • [27] The effect of contrast material on radiation dose during computed tomography pulmonary angiography
    Karami, Haleh
    Miri-Hakimabad, Hashem
    Hoseinian-Azghadi, Elie
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2020, 30 (03): : 211 - 221
  • [28] Patient radiation dose from computed tomography angiography and digital subtraction angiography of the brain
    Netwong, Y.
    Krisanachinda, A.
    13TH SOUTH-EAST ASIAN CONGRESS OF MEDICAL PHYSICS 2015 (SEACOMP), 2016, 694
  • [29] Coronary computed tomography angiography with prospective electrocardiography triggering: a systematic review of image quality and radiation dose
    Sabarudin, Akmal
    Sun, Zhonghua
    Ng, Kwan-Hoong
    SINGAPORE MEDICAL JOURNAL, 2013, 54 (01) : 15 - 23
  • [30] Cardiac Computed Tomography Angiography With Automatic Tube Potential Selection Effects on Radiation Dose and Image Quality
    Ghoshhajra, Brian B.
    Engel, Leif-Christopher
    Karolyi, Mihaly
    Sidhu, Manavjot Singh
    Wai, Bryan
    Barreto, Mitya
    Shanmugam, Uthamalingam
    Hoffmann, Udo
    Brady, Thomas J.
    Kalra, Manudeep
    Abbara, Suhny
    JOURNAL OF THORACIC IMAGING, 2013, 28 (01) : 40 - 48