Coherent Bistatic 3-D Ultrasound Imaging Using Two Sparse Matrix Arrays

被引:5
|
作者
De Hoop, Hein [1 ]
Vermeulen, Marieke [1 ]
Schwab, Hans-Martin [1 ]
Lopata, Richard G. P. [1 ]
机构
[1] Eindhoven Univ Technol, Dept Biomed Engn, Photoacoust & Ultrasound Lab Eindhoven, NL-5600 Eindhoven, Netherlands
基金
欧洲研究理事会;
关键词
Apertures; Ultrasonic imaging; Imaging; Transducers; Sparse matrices; Multiplexing; Three-dimensional displays; 3-D ultrasound; acquisition; bistatic; coherent; sparse arrays; SEGMENTATION; REGISTRATION;
D O I
10.1109/TUFFC.2022.3233158
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In the last decade, many advances have been made in high frame rate 3-D ultrasound imaging, including more flexible acquisition systems, transmit (TX) sequences, and transducer arrays. Compounding multiangle transmits of diverging waves has shown to be fast and effective for 2-D matrix arrays, where heterogeneity between transmits is key in optimizing the image quality. However, the anisotropy in contrast and resolution remains a drawback that cannot be overcome with a single transducer. In this study, a bistatic imaging aperture is demonstrated that consists of two synchronized matrix (32 x 32) arrays, allowing for fast interleaved transmits with a simultaneous receive (RX). First, for a single array, the aperture efficiency for high volume rate imaging was evaluated between sparse random arrays and fully multiplexed arrays. Second, the performance of the bistatic acquisition scheme was analyzed for various positions on a wire phantom and was showcased in a dynamic setup mimicking the human abdomen and aorta. Sparse array volume images were equal in resolution and lower in contrast compared to fully multiplexed arrays but can efficiently minimize decorrelation during motion for multiaperture imaging. The dual-array imaging aperture improved the spatial resolution in the direction of the second transducer, reducing the average volumetric speckle size with 72% and the axial-lateral eccentricity with 8%. In the aorta phantom, the angular coverage increased by a factor of 3 in the axial-lateral plane, raising the wall-lumen contrast with 16% compared to single-array images, despite accumulation of thermal noise in the lumen.
引用
收藏
页码:182 / 196
页数:15
相关论文
共 50 条
  • [41] Rectilinear 3-D ultrasound imaging using synthetic aperture techniques
    Daher, NM
    Yen, JT
    2004 IEEE Ultrasonics Symposium, Vols 1-3, 2004, : 1270 - 1273
  • [42] SPACEBORNE-AIRBORNE BISTATIC SAR 3-D IMAGING USING LINEAR ARRAY ANTENNA
    Wu, Wen-Jun
    Zhang, Xiao-Ling
    Wei, Shun-Jun
    2015 IEEE 5TH ASIA-PACIFIC CONFERENCE ON SYNTHETIC APERTURE RADAR (APSAR), 2015, : 62 - 66
  • [43] Advances in 3-D vascular ultrasound imaging
    Fenster, Aaron
    American Society of Mechanical Engineers, Bioengineering Division (Publication) BED, 1999, 43 : 83 - 84
  • [44] Efficient Two-Pass 3-D Speckle Tracking for Ultrasound Imaging
    Jeng, Geng-Shi
    Zontak, Maria
    Parajuli, Nripesh
    Lu, Allen
    Ta, Kevinminh
    Sinusas, Albert J.
    Duncan, James S.
    O'Donnell, Matthew
    IEEE ACCESS, 2018, 6 : 17415 - 17428
  • [45] Convex Optimization-Based Design of Sparse Arrays for 3-D Near-Field Imaging
    Wang, Shuoguang
    Li, Shiyong
    Ren, Bailing
    Miao, Ke
    Zhao, Guoqiang
    Sun, Houjun
    IEEE SENSORS JOURNAL, 2023, 23 (09) : 9640 - 9648
  • [46] Coherent 3-D echo detection for ultrasonic imaging
    Chalmond, B
    Coldefy, F
    Goubet, E
    Lavayssière, B
    IEEE TRANSACTIONS ON SIGNAL PROCESSING, 2003, 51 (03) : 592 - 601
  • [47] Top-Orthogonal-to-Bottom-Electrode (TOBE) CMUT Arrays for 3-D Ultrasound Imaging
    Sampaleanu, Alex
    Zhang, Peiyu
    Kshirsagar, Abhijeet
    Moussa, Walied
    Zemp, Roger J.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2014, 61 (02) : 266 - 276
  • [48] 3-D imaging correlography and coherent image reconstruction
    Fienup, JR
    Paxman, RG
    Reiley, MF
    Thelen, BJ
    DIGITAL IMAGE RECOVERY AND SYNTHESIS IV, 1999, 3815 : 60 - 69
  • [49] Fourier-Based Fast 3-D Ultrasound Imaging Using Row-Column-Addressed 2-D Arrays
    Lin, Shang-Ching
    Li, Pai-Chi
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2024, 71 (01) : 85 - 101
  • [50] A Multilook Processing Approach to 3-D ISAR Imaging Using Phased Arrays
    Raj, Raghu G.
    Rodenbeck, Christopher T.
    Lipps, Ronald D.
    Jansen, Robert W.
    Ainsworth, Thomas L.
    IEEE GEOSCIENCE AND REMOTE SENSING LETTERS, 2018, 15 (09) : 1412 - 1416