Coherent Bistatic 3-D Ultrasound Imaging Using Two Sparse Matrix Arrays

被引:5
|
作者
De Hoop, Hein [1 ]
Vermeulen, Marieke [1 ]
Schwab, Hans-Martin [1 ]
Lopata, Richard G. P. [1 ]
机构
[1] Eindhoven Univ Technol, Dept Biomed Engn, Photoacoust & Ultrasound Lab Eindhoven, NL-5600 Eindhoven, Netherlands
基金
欧洲研究理事会;
关键词
Apertures; Ultrasonic imaging; Imaging; Transducers; Sparse matrices; Multiplexing; Three-dimensional displays; 3-D ultrasound; acquisition; bistatic; coherent; sparse arrays; SEGMENTATION; REGISTRATION;
D O I
10.1109/TUFFC.2022.3233158
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In the last decade, many advances have been made in high frame rate 3-D ultrasound imaging, including more flexible acquisition systems, transmit (TX) sequences, and transducer arrays. Compounding multiangle transmits of diverging waves has shown to be fast and effective for 2-D matrix arrays, where heterogeneity between transmits is key in optimizing the image quality. However, the anisotropy in contrast and resolution remains a drawback that cannot be overcome with a single transducer. In this study, a bistatic imaging aperture is demonstrated that consists of two synchronized matrix (32 x 32) arrays, allowing for fast interleaved transmits with a simultaneous receive (RX). First, for a single array, the aperture efficiency for high volume rate imaging was evaluated between sparse random arrays and fully multiplexed arrays. Second, the performance of the bistatic acquisition scheme was analyzed for various positions on a wire phantom and was showcased in a dynamic setup mimicking the human abdomen and aorta. Sparse array volume images were equal in resolution and lower in contrast compared to fully multiplexed arrays but can efficiently minimize decorrelation during motion for multiaperture imaging. The dual-array imaging aperture improved the spatial resolution in the direction of the second transducer, reducing the average volumetric speckle size with 72% and the axial-lateral eccentricity with 8%. In the aorta phantom, the angular coverage increased by a factor of 3 in the axial-lateral plane, raising the wall-lumen contrast with 16% compared to single-array images, despite accumulation of thermal noise in the lumen.
引用
收藏
页码:182 / 196
页数:15
相关论文
共 50 条
  • [31] Quantification of thyroid volume using 3-D ultrasound imaging
    Kollorz, Eva N. K.
    Hahn, Dieter A.
    Linke, Rainer
    Goecke, Tamme W.
    Hornegger, Joachim
    Kuwert, Torsten
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (04) : 457 - 466
  • [32] Detection and Localization of Pipeline Leaks Using 3-D Bistatic Subsurface Imaging Radars
    Aljurbua, Abdulrahman
    Sarabandi, Kamal
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2022, 60
  • [33] Coherent 3-D imaging of model targets
    Marr, RA
    Lammers, UHW
    PROCEEDINGS OF THE 1997 IEEE NATIONAL RADAR CONFERENCE, 1997, : 289 - 294
  • [34] Comparison of digital beamforming algorithms for 3-D terahertz imaging with sparse multistatic line arrays
    Baccouche B.
    Agostini P.
    Schneider F.
    Sauer-Greff W.
    Urbansky R.
    Friederich F.
    Advances in Radio Science, 2017, 15 : 283 - 292
  • [35] Design of Low-Complexity 3-D Underwater Imaging System With Sparse Planar Arrays
    Zhao, Dongdong
    Zhou, Fan
    Jiang, Rongxin
    Liu, Xuesong
    Chen, Yaowu
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2019, 68 (10) : 3418 - 3432
  • [36] 3-D companding using linear arrays for improved strain imaging
    Insana, MF
    Chaturvedi, P
    Hall, TJ
    Bilgen, M
    1997 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 & 2, 1997, : 1435 - 1438
  • [37] 3-D ultrasound texture classification using run difference matrix
    Chen, WM
    Chang, RF
    Kuo, SJ
    Chang, CS
    Moon, WK
    Chen, ST
    Chen, DR
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (06): : 763 - 770
  • [38] SPRITE: 3-D SParse Radar Imaging TEchnique
    Benoudiba-Campanini, Thomas
    Giovannelli, Jean-Francois
    Minvielle, Pierre
    IEEE TRANSACTIONS ON COMPUTATIONAL IMAGING, 2020, 6 : 1059 - 1069
  • [39] Sparse Signal Methods for 3-D Radar Imaging
    Austin, Christian D.
    Ertin, Emre
    Moses, Randolph L.
    IEEE JOURNAL OF SELECTED TOPICS IN SIGNAL PROCESSING, 2011, 5 (03) : 408 - 423
  • [40] 3-D Ultrasound Imaging Of Lung Lesions
    Warren, W.
    Parrish, S. C.
    Browning, R.
    Malafronte, P.
    Nations, J.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2016, 193