Coherent Bistatic 3-D Ultrasound Imaging Using Two Sparse Matrix Arrays

被引:5
作者
De Hoop, Hein [1 ]
Vermeulen, Marieke [1 ]
Schwab, Hans-Martin [1 ]
Lopata, Richard G. P. [1 ]
机构
[1] Eindhoven Univ Technol, Dept Biomed Engn, Photoacoust & Ultrasound Lab Eindhoven, NL-5600 Eindhoven, Netherlands
基金
欧洲研究理事会;
关键词
Apertures; Ultrasonic imaging; Imaging; Transducers; Sparse matrices; Multiplexing; Three-dimensional displays; 3-D ultrasound; acquisition; bistatic; coherent; sparse arrays; SEGMENTATION; REGISTRATION;
D O I
10.1109/TUFFC.2022.3233158
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In the last decade, many advances have been made in high frame rate 3-D ultrasound imaging, including more flexible acquisition systems, transmit (TX) sequences, and transducer arrays. Compounding multiangle transmits of diverging waves has shown to be fast and effective for 2-D matrix arrays, where heterogeneity between transmits is key in optimizing the image quality. However, the anisotropy in contrast and resolution remains a drawback that cannot be overcome with a single transducer. In this study, a bistatic imaging aperture is demonstrated that consists of two synchronized matrix (32 x 32) arrays, allowing for fast interleaved transmits with a simultaneous receive (RX). First, for a single array, the aperture efficiency for high volume rate imaging was evaluated between sparse random arrays and fully multiplexed arrays. Second, the performance of the bistatic acquisition scheme was analyzed for various positions on a wire phantom and was showcased in a dynamic setup mimicking the human abdomen and aorta. Sparse array volume images were equal in resolution and lower in contrast compared to fully multiplexed arrays but can efficiently minimize decorrelation during motion for multiaperture imaging. The dual-array imaging aperture improved the spatial resolution in the direction of the second transducer, reducing the average volumetric speckle size with 72% and the axial-lateral eccentricity with 8%. In the aorta phantom, the angular coverage increased by a factor of 3 in the axial-lateral plane, raising the wall-lumen contrast with 16% compared to single-array images, despite accumulation of thermal noise in the lumen.
引用
收藏
页码:182 / 196
页数:15
相关论文
共 46 条
  • [11] 4-D Ultrafast Shear-Wave Imaging
    Gennisson, Jean-Luc
    Provost, Jean
    Deffieux, Thomas
    Papadacci, Clement
    Imbault, Marion
    Pernot, Mathieu
    Tanter, Mickael
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2015, 62 (06) : 1059 - 1065
  • [12] 3-D Super-Resolution Ultrasound Imaging With a 2-D Sparse Array
    Harput, Sevan
    Tortoli, Piero
    Eckersley, Robert J.
    Dunsby, Chris
    Tang, Meng-Xing
    Christensen-Jeffries, Kirsten
    Ramalli, Alessandro
    Brown, Jemma
    Zhu, Jiaqi
    Zhang, Ge
    Leow, Chee Hau
    Toulemonde, Matthieu
    Boni, Enrico
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2020, 67 (02) : 269 - 277
  • [13] SARUS: A Synthetic Aperture Real-Time Ultrasound System
    Jensen, Jorgen Arendt
    Holten-Lund, Hans
    Nilsson, Ronnie Thorup
    Hansen, Martin
    Larsen, Ulrik Darling
    Domsten, Rune Petter
    Tomov, Borislav Gueorguiev
    Stuart, Matthias Bo
    Nikolov, Svetoslav Ivanov
    Pihl, Michael Johannes
    Du, Yigang
    Rasmussen, Joachim Hee
    Rasmussen, Morten Fischer
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2013, 60 (09) : 1838 - 1852
  • [14] Le Moign G, 2019, IEEE INT ULTRA SYM, P904, DOI [10.1109/ultsym.2019.8925839, 10.1109/ULTSYM.2019.8925839]
  • [15] Cardiac Strain Imaging Using Multi-Perspective Ultrafast Ultrasound
    Liu, Peilu
    Muller, Jan-Willem
    Schwab, Hans-Martin
    Lopata, Richard
    [J]. FRONTIERS IN PHYSICS, 2022, 10
  • [16] High frame rate multi-perspective cardiac ultrasound imaging using phased array probes
    Liu, Peilu
    de Hoop, Hein
    Schwab, Hans-Martin
    Lopata, Richard G. P.
    [J]. ULTRASONICS, 2022, 123
  • [17] Assessment of mechanical properties of porcine aortas under physiological loading conditions using vascular elastography
    Mascarenhas, Edgar J. S.
    Peters, Mathijs F. J.
    Nijs, Jan
    Rutten, Marcel C. M.
    van de Vosse, Frans N.
    Lopata, Richard G. P.
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2016, 59 : 185 - 196
  • [18] Architecture for an Ultrasound Advanced Open Platform With an Arbitrary Number of Independent Channels
    Mazierli, Daniele
    Ramalli, Alessandro
    Boni, Enrico
    Guidi, Francesco
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2021, 15 (03) : 486 - 496
  • [19] Coherent Plane-Wave Compounding for Very High Frame Rate Ultrasonography and Transient Elastography
    Montaldo, Gabriel
    Tanter, Mickael
    Bercoff, Jeremy
    Benech, Nicolas
    Fink, Mathias
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (03) : 489 - 506
  • [20] FREEHAND 3-D ULTRASOUND IMAGING: A SYSTEMATIC REVIEW
    Mozaffari, Mohammad Hamed
    Lee, Won-Sook
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (10) : 2099 - 2124