Coherent Bistatic 3-D Ultrasound Imaging Using Two Sparse Matrix Arrays

被引:5
作者
De Hoop, Hein [1 ]
Vermeulen, Marieke [1 ]
Schwab, Hans-Martin [1 ]
Lopata, Richard G. P. [1 ]
机构
[1] Eindhoven Univ Technol, Dept Biomed Engn, Photoacoust & Ultrasound Lab Eindhoven, NL-5600 Eindhoven, Netherlands
基金
欧洲研究理事会;
关键词
Apertures; Ultrasonic imaging; Imaging; Transducers; Sparse matrices; Multiplexing; Three-dimensional displays; 3-D ultrasound; acquisition; bistatic; coherent; sparse arrays; SEGMENTATION; REGISTRATION;
D O I
10.1109/TUFFC.2022.3233158
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In the last decade, many advances have been made in high frame rate 3-D ultrasound imaging, including more flexible acquisition systems, transmit (TX) sequences, and transducer arrays. Compounding multiangle transmits of diverging waves has shown to be fast and effective for 2-D matrix arrays, where heterogeneity between transmits is key in optimizing the image quality. However, the anisotropy in contrast and resolution remains a drawback that cannot be overcome with a single transducer. In this study, a bistatic imaging aperture is demonstrated that consists of two synchronized matrix (32 x 32) arrays, allowing for fast interleaved transmits with a simultaneous receive (RX). First, for a single array, the aperture efficiency for high volume rate imaging was evaluated between sparse random arrays and fully multiplexed arrays. Second, the performance of the bistatic acquisition scheme was analyzed for various positions on a wire phantom and was showcased in a dynamic setup mimicking the human abdomen and aorta. Sparse array volume images were equal in resolution and lower in contrast compared to fully multiplexed arrays but can efficiently minimize decorrelation during motion for multiaperture imaging. The dual-array imaging aperture improved the spatial resolution in the direction of the second transducer, reducing the average volumetric speckle size with 72% and the axial-lateral eccentricity with 8%. In the aorta phantom, the angular coverage increased by a factor of 3 in the axial-lateral plane, raising the wall-lumen contrast with 16% compared to single-array images, despite accumulation of thermal noise in the lumen.
引用
收藏
页码:182 / 196
页数:15
相关论文
共 46 条
  • [1] Image-guided control of a robot for medical ultrasound
    Abolmaesumi, P
    Salcudean, SE
    Zhu, WH
    Sirouspour, MR
    DiMaio, SP
    [J]. IEEE TRANSACTIONS ON ROBOTICS AND AUTOMATION, 2002, 18 (01): : 11 - 23
  • [2] Bernal M., 2021, P IEEE INT ULTR S IU, P1
  • [3] High-frame-rate volume imaging using sparse-random-aperture compounding
    Bernal, Miguel
    Cunitz, Bryan
    Rohrbach, Daniel
    Daigle, Ron
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (17)
  • [4] A METHOD FOR REGISTRATION OF 3-D SHAPES
    BESL, PJ
    MCKAY, ND
    [J]. IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1992, 14 (02) : 239 - 256
  • [5] Feasibility of Swept Synthetic Aperture Ultrasound Imaging
    Bottenus, Nick
    Long, Will
    Zhang, Haichong K.
    Jakovljevic, Marko
    Bradway, David P.
    Boctor, Emad M.
    Trahey, Gregg E.
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2016, 35 (07) : 1676 - 1685
  • [6] Caiani E. G., 2012, COMPREHENSIVE ATLAS, V1st, P1
  • [7] 4D ultrafast ultrasound flow imaging: in vivo quantification of arterial volumetric flow rate in a single heartbeat
    Correia, Mafalda
    Provost, Jean
    Tanter, Mickael
    Pernot, Mathieu
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (23) : L48 - L61
  • [8] Multiperspective Ultrasound Strain Imaging of the Abdominal Aorta
    de Hoop, Hein
    Petterson, Niels J.
    van de Vosse, Frans N.
    van Sambeek, Marc R. H. M.
    Schwab, Hans-Martin
    Lopata, Richard G. P.
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (11) : 3714 - 3724
  • [9] Automated 3D geometry segmentation of the healthy and diseased carotid artery in free-hand, probe tracked ultrasound images
    de Ruijter, Joerik
    van Sambeek, Marc
    van de Vosse, Frans
    Lopata, Richard
    [J]. MEDICAL PHYSICS, 2020, 47 (03) : 1034 - 1047
  • [10] Improving plane wave ultrasound imaging through real-time beamformation across multiple arrays
    Foiret, Josquin
    Cai, Xiran
    Bendjador, Hanna
    Park, Eun-Yeong
    Kamaya, Aya
    Ferrara, Katherine W.
    [J]. SCIENTIFIC REPORTS, 2022, 12 (01)