Coherent Bistatic 3-D Ultrasound Imaging Using Two Sparse Matrix Arrays

被引:5
|
作者
De Hoop, Hein [1 ]
Vermeulen, Marieke [1 ]
Schwab, Hans-Martin [1 ]
Lopata, Richard G. P. [1 ]
机构
[1] Eindhoven Univ Technol, Dept Biomed Engn, Photoacoust & Ultrasound Lab Eindhoven, NL-5600 Eindhoven, Netherlands
基金
欧洲研究理事会;
关键词
Apertures; Ultrasonic imaging; Imaging; Transducers; Sparse matrices; Multiplexing; Three-dimensional displays; 3-D ultrasound; acquisition; bistatic; coherent; sparse arrays; SEGMENTATION; REGISTRATION;
D O I
10.1109/TUFFC.2022.3233158
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In the last decade, many advances have been made in high frame rate 3-D ultrasound imaging, including more flexible acquisition systems, transmit (TX) sequences, and transducer arrays. Compounding multiangle transmits of diverging waves has shown to be fast and effective for 2-D matrix arrays, where heterogeneity between transmits is key in optimizing the image quality. However, the anisotropy in contrast and resolution remains a drawback that cannot be overcome with a single transducer. In this study, a bistatic imaging aperture is demonstrated that consists of two synchronized matrix (32 x 32) arrays, allowing for fast interleaved transmits with a simultaneous receive (RX). First, for a single array, the aperture efficiency for high volume rate imaging was evaluated between sparse random arrays and fully multiplexed arrays. Second, the performance of the bistatic acquisition scheme was analyzed for various positions on a wire phantom and was showcased in a dynamic setup mimicking the human abdomen and aorta. Sparse array volume images were equal in resolution and lower in contrast compared to fully multiplexed arrays but can efficiently minimize decorrelation during motion for multiaperture imaging. The dual-array imaging aperture improved the spatial resolution in the direction of the second transducer, reducing the average volumetric speckle size with 72% and the axial-lateral eccentricity with 8%. In the aorta phantom, the angular coverage increased by a factor of 3 in the axial-lateral plane, raising the wall-lumen contrast with 16% compared to single-array images, despite accumulation of thermal noise in the lumen.
引用
收藏
页码:182 / 196
页数:15
相关论文
共 50 条
  • [1] 3-D Coherent Multitransducer Ultrasound Imaging With Sparse Spiral Arrays
    Peralta, Laura
    Mazierli, Daniele
    Gomez, Alberto
    Hajnal, Joseph, V
    Tortoli, Piero
    Ramalli, Alessandro
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2023, 70 (03) : 197 - 206
  • [2] Feasibility of 3-D Coherent Multi-Transducer Ultrasound Imaging with Two Sparse Arrays
    Peralta, Laura
    Ramalli, Alessandro
    Christensen-Jeffries, Kirsten
    Harput, Sevan
    Tortoli, Piero
    Hajnal, Joseph, V
    INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS 2021), 2021,
  • [3] Experimental demonstration of the coherent use of two sparse arrays for 3-D imaging
    Peralta, Laura
    Mazierli, Daniele
    Gomez, Alberto
    Hajnal, Joseph V.
    Tortoli, Piero
    Ramalli, Alessandro
    2022 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS), 2022,
  • [4] Two dimensional Arrays for 3-D ultrasound Imaging
    Smith, SW
    Lee, W
    Light, ED
    Yen, JT
    Wolf, P
    Idriss, S
    2002 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2002, : 1545 - 1553
  • [5] Experimental 3-D Ultrasound Imaging with 2-D Sparse Arrays using Focused and Diverging Waves
    Roux, Emmanuel
    Varray, Francois
    Petrusca, Lorena
    Cachard, Christian
    Tortoli, Piero
    Liebgott, Herve
    SCIENTIFIC REPORTS, 2018, 8
  • [6] Experimental 3-D Ultrasound Imaging with 2-D Sparse Arrays using Focused and Diverging Waves
    Emmanuel Roux
    François Varray
    Lorena Petrusca
    Christian Cachard
    Piero Tortoli
    Hervé Liebgott
    Scientific Reports, 8
  • [7] Sparse Convolutional Beamforming for 3-D Ultrafast Ultrasound Imaging
    Cohen, Regev
    Fingerhut, Nitai
    Varray, Francois
    Liebgott, Herve
    Eldar, Yonina C.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2021, 68 (07) : 2444 - 2459
  • [8] The application of 3-D coherent scattering model on bistatic SAR imaging of virtual vegetation
    Qiao, Xinya
    Liu, Dawei
    Ding, Yafang
    PROCEEDINGS OF 2017 7TH IEEE INTERNATIONAL SYMPOSIUM ON MICROWAVE, ANTENNA, PROPAGATION, AND EMC TECHNOLOGIES (MAPE), 2017, : 454 - 456
  • [9] 3-D motion tracking and vascular strain imaging using bistatic dual aperture ultrasound acquisitions
    de Hoop, Hein
    Maas, Esther
    Muller, Jan-Willem
    Schwab, Hans-Martin
    Lopata, Richard
    PHYSICS IN MEDICINE AND BIOLOGY, 2025, 70 (04):
  • [10] Hybrid Volume Beamforming for 3-D Ultrasound Imaging using 2-D CMUT Arrays
    Kim, Bae-Hyung
    Song, Tai-Kyong
    Yoo, Yangmo
    Chang, Jin Ho
    Lee, Seunghun
    Kim, Youngil
    Cho, Kyungil
    Song, Jongkeun
    2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2012, : 2246 - 2249