Modification of titanium orthopedic implants with bioactive glass: a systematic review of in vivo and in vitro studies

被引:10
|
作者
Liang, Jin [1 ]
Lu, Xinyue [2 ]
Zheng, Xinru [2 ]
Li, Yu Ru [2 ]
Geng, Xiaoyu [2 ]
Sun, Kexin [2 ]
Cai, Hongxin [3 ]
Jia, Qi [3 ]
Jiang, Heng Bo [2 ]
Liu, Kai [4 ]
机构
[1] Shandong First Med Univ, Sch Stomatol, Dept Oral & Maxillofacial Surg, Jinan, Shandong, Peoples R China
[2] Shandong First Med Univ, Sch Stomatol, CONVERSATIONALIST Club & Dept Stomatol Technol, Jinan, Shandong, Peoples R China
[3] Yonsei Univ, Dept & Res Inst Dent Biomat & Bioengn, Coll Dent, Seoul, South Korea
[4] Shandong First Med Univ, Inst Basic Med, Jinan, Shandong, Peoples R China
关键词
bone regeneration; surface modification; biomaterials; tissue engineering; bioglass; bioactive materials; PULSED-LASER DEPOSITION; MAGNETRON-SPUTTERED BIOGLASS; COMPOSITE COATINGS; SURFACE MODIFICATIONS; IONIC PRODUCTS; ELECTROPHORETIC DEPOSITION; STEM-CELLS; OSTEOGENIC DIFFERENTIATION; ANTIBACTERIAL PROPERTIES; HUMAN OSTEOBLASTS;
D O I
10.3389/fbioe.2023.1269223
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Bioactive glasses (BGs) are ideal biomaterials in the field of bio-restoration due to their excellent biocompatibility. Titanium alloys are widely used as a bone graft substitute material because of their excellent corrosion resistance and mechanical properties; however, their biological inertness makes them prone to clinical failure. Surface modification of titanium alloys with bioactive glass can effectively combine the superior mechanical properties of the substrate with the biological properties of the coating material. In this review, the relevant articles published from 2013 to the present were searched in four databases, namely, Web of Science, PubMed, Embase, and Scopus, and after screening, 49 studies were included. We systematically reviewed the basic information and the study types of the included studies, which comprise in vitro experiments, animal tests, and clinical trials. In addition, we summarized the applied coating technologies, which include pulsed laser deposition (PLD), electrophoretic deposition, dip coating, and magnetron sputtering deposition. The superior biocompatibility of the materials in terms of cytotoxicity, cell activity, hemocompatibility, anti-inflammatory properties, bioactivity, and their good bioactivity in terms of osseointegration, osteogenesis, angiogenesis, and soft tissue adhesion are discussed. We also analyzed the advantages of the existing materials and the prospects for further research. Even though the current research status is not extensive enough, it is still believed that BG-coated Ti implants have great clinical application prospects.
引用
收藏
页数:32
相关论文
共 50 条
  • [41] Surface Modification of Porous Titanium and Titanium Alloy Implants Manufactured by Selective Laser Melting: A Review
    Liu, Weijun
    Li, Wanqiu
    Wang, Huiru
    Bian, Hongyou
    Zhang, Kai
    ADVANCED ENGINEERING MATERIALS, 2023, 25 (21)
  • [42] A review on mechanical and In-vitro studies of polymer reinforced bioactive glass-scaffolds and their fabrication techniques
    Jain, Satish
    Gujjala, Raghavendra
    Azeem, P. Abdul
    Ojha, Shakuntala
    Samudrala, Raj Kumar
    CERAMICS INTERNATIONAL, 2022, 48 (05) : 5908 - 5921
  • [43] Studies on novel bioactive glasses and bioactive glass-nano-HAp composites suitable for coating on metallic implants
    Soundrapandian, Chidambaram
    Bharati, Sanghamitra
    Basu, Debabrata
    Datta, Someswar
    CERAMICS INTERNATIONAL, 2011, 37 (03) : 759 - 769
  • [44] Surface bioactivity modification of titanium by CO2 plasma treatment and induction of hydroxyapatite: In vitro and in vivo studies
    Hu, Xixue
    Shen, Hong
    Shuai, Kegang
    Zhang, Enwei
    Bai, Yanjie
    Cheng, Yan
    Xiong, Xiaoling
    Wang, Shenguo
    Fang, Jing
    Wei, Shicheng
    APPLIED SURFACE SCIENCE, 2011, 257 (06) : 1813 - 1823
  • [45] Electric discharge machining - A potential choice for surface modification of metallic implants for orthopedic applications: A review
    Prakash, Chander
    Kansal, Harmesh K.
    Pabla, B. S.
    Puri, Sanjeev
    Aggarwal, Aditya
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART B-JOURNAL OF ENGINEERING MANUFACTURE, 2016, 230 (02) : 331 - 353
  • [46] Chitosan coatings on titanium-based implants - From development to characterization and behavior: A systematic review
    Tardelli, Juliana Dias Corpa
    Schiavon, Marco Antonio
    dos Reis, Andrea Candido
    CARBOHYDRATE POLYMERS, 2024, 344
  • [47] In vitro bioactivity and biocompatibility of magnesium implants coated with poly(methyl methacrylate)- bioactive glass composite
    Rouein, Zanko
    Jafari, Hassan
    Pishbin, Fatemehsadat
    Mohandes, Fatemeh
    Simchi, Abdolreza
    MATERIALS TODAY COMMUNICATIONS, 2022, 33
  • [48] Studies on effect of CuO addition on mechanical properties and in vitro cytocompatibility in 1393 bioactive glass scaffold
    Ali, Akher
    Ershad, Md
    Vyas, Vikash Kumar
    Hira, Sumit Kumar
    Manna, Partha Pratim
    Singh, B. N.
    Yadav, Shushma
    Srivastava, P.
    Singh, S. P.
    Pyare, Ram
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2018, 93 : 341 - 355
  • [49] In Vitro and In Vivo Osteogenic Activity of Titanium Implants Coated by Pulsed Laser Deposition with a Thin Film of Fluoridated Hydroxyapatite
    Chen, Luyuan
    Komasa, Satoshi
    Hashimoto, Yoshiya
    Hontsu, Shigeki
    Okazaki, Joji
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2018, 19 (04)
  • [50] Influence of Surface Roughness on the Adhesion of Hydroxyapatite Coatings to Titanium and Titanium Alloy Surfaces: A Systematic Review of in vitro Experimental Studies
    de Melo-Soares, Victor
    Gazott-Simoes, Isadora
    dos Reis, Andrea Candido
    Valente, Mariana Lima da Costa
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2025, 33 (01): : 93 - 103