Development and validation of a fast UPLC-MS/MS screening method for the detection of 68 psychoactive drugs and metabolites in whole blood and application to post-mortem cases

被引:8
作者
Barone, Rossella [1 ]
Giorgetti, Arianna [1 ]
Cardella, Rachele [1 ]
Rossi, Francesca [1 ]
Garagnani, Marco [1 ]
Pascali, Jennifer Paola [2 ]
Mohamed, Susan [1 ]
Fais, Paolo [1 ]
Pelletti, Guido [1 ]
机构
[1] Univ Bologna, Dept Med & Surg Sci, Unit Legal Med, Via Irnerio 49, I-40126 Bologna, Italy
[2] Univ Padua, Dept Cardiac Thorac Vasc Sci & Publ Hlth, Via Falloppio 50, I-35121 Padua, Italy
关键词
Forensic toxicology; Psychoactive substances; LC-MS; MS; Blood; Post-mortem; Validation; SOLID-PHASE EXTRACTION; MASS-SPECTROMETRY; LIQUID; PROTEIN;
D O I
10.1016/j.jpba.2023.115315
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report a rapid and sensitive LC-MS/MS method that allows the simultaneous detection of 68 commonly prescribed antidepressants, benzodiazepines, neuroleptics, and metabolites in whole blood with a small sample volume after a rapid protein precipitation. The method was also tested on post-mortem blood from 85 forensic autopsies. Three sets of commercial serum calibrators containing a mix of prescription drugs of increasing concentration were spiked with red blood cells (RBC) to obtain 6 calibrators (3 "serum calibrators" and 3 "blood calibrators"). Curves obtained from serum calibrators and from blood calibrators were compared using a Spearman correlation test and by analyzing slopes and intercepts, to assess if the points from six calibrators could be plotted together in a single calibration model. The validation plan included interference studies, calibration model, carry-over, bias, within-run and between-run precision, limit of detection (LOD), limit of quantification (LOQ), matrix effect and dilution integrity. Four deuterated Internal Standards (Nordiazepam-D5, Citalopram-D6, Ketamine-D4 and Amphetamine-D5) and two different dilutions were assessed. Analyses were performed using an Acquity UPLC (R) System coupled with triple quadrupole detector Xevo TQD (R). The degree of agreement with a previously validated method was calculated on whole blood samples of 85 post-mortem cases, by per-forming a Spearman correlation test with a Bland-Altman plot. Percentage error between the two methods was evaluated. Slopes and intercepts of curves obtained from serum calibrators and from blood calibrators showed a good correlation, and the calibration model was built plotting all points together. No interferences were found. The calibration curve appeared to provide a better fit of the data using an unweighted linear model. Negligible carry-over was observed, and very good linearity, precision, bias, matrix effect and dilution integrity were achieved. The LOD and the LOQ were at the lower limits of the therapeutic range for the tested drugs. In a series of 85 forensic cases, 11 antidepressants, 11 benzodiazepines and 8 neuroleptics were detected. For all analytes, a very good agreement between the new method and the validated method was demonstrated. The innovation of our method consists in the use of commercial calibrators, readily available to most forensic toxicology labora-tories, for the validation of a fast, inexpensive, wide-panel LC-MS/MS method that can be used as a reliable and accurate screening for psychotropic drug in postmortem samples. As observed in the implementation on real cases, this method could be profitably applied in forensic cases.
引用
收藏
页数:9
相关论文
共 29 条
  • [21] Optimization of cloned enzyme donor immunoassay cut-offs for drugs of abuse in post-mortem whole blood
    Pelletti, Guido
    Rossi, Francesca
    Garagnani, Marco
    Barone, Rossella
    Roffi, Raffaella
    Fais, Paolo
    Pelotti, Susi
    [J]. FORENSIC SCIENCE INTERNATIONAL, 2020, 312
  • [22] Prevalence of therapeutic drugs in blood of drivers involved in traffic crashes in the area of Bologna, Italy
    Pelletti, Guido
    Verstraete, Alain G.
    Reyns, Tim
    Barone, Rossella
    Rossi, Francesca
    Garagnani, Marco
    Pelotti, Susi
    [J]. FORENSIC SCIENCE INTERNATIONAL, 2019, 302
  • [23] Safe drugs in drug facilitated crimes and acute intoxications in Northern Italy
    Pelletti, Guido
    Garagnani, Marco
    Rossi, Francesca
    Roffi, Raffaella
    Banchini, Antonio
    Pelotti, Susi
    [J]. FORENSIC SCIENCE MEDICINE AND PATHOLOGY, 2018, 14 (04) : 442 - 449
  • [24] Quantitative Analysis of 26 Opioids, Cocaine, and Their Metabolites in Human Blood by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry
    Ramirez Fernandez, Maria del Mar
    Wille, Sarah M. R.
    Kummer, Nathalie
    Di Fazio, Vincent
    Ruyssinckx, Evi
    Samyn, Nele
    [J]. THERAPEUTIC DRUG MONITORING, 2013, 35 (04) : 510 - 521
  • [25] Recent advances of liquid chromatography-(tandem) mass spectrometry in clinical and forensic toxicology - An update
    Remane, Daniela
    Wissenbach, Dirk K.
    Peters, Frank T.
    [J]. CLINICAL BIOCHEMISTRY, 2016, 49 (13-14) : 1051 - 1071
  • [26] Revisited: Therapeutic and toxic blood concentrations of more than 1100 drugs and other xenobiotics
    Schulz, Martin
    Schmoldt, Achim
    Andresen-Streichert, Hilke
    Iwersen-Bergmann, Stefanie
    [J]. CRITICAL CARE, 2020, 24 (01):
  • [27] Targeted M.R.M, 2010, MRM TQD VERS 2 DUAL
  • [28] A novel screening method for 64 new psychoactive substances and 5 amphetamines in blood by LC-MS/MS and application to real cases
    Vaiano, Fabio
    Busardo, Francesco P.
    Palumbo, Diego
    Kyriakou, Chrystalla
    Fioravanti, Alessia
    Catalani, Valeria
    Mari, Francesco
    Bertol, Elisabetta
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2016, 129 : 441 - 449
  • [29] Intra-individual alterations of serum markers routinely used in forensic pathology depending on increasing post-mortem interval
    Woydt, Lina
    Bernhard, Michael
    Kirsten, Holger
    Burkhardt, Ralph
    Hammer, Niels
    Gries, Andre
    Dressler, Jan
    Ondruschka, Benjamin
    [J]. SCIENTIFIC REPORTS, 2018, 8