Theoretic and experimental performance of a grid-connected photovoltaic system: Multiple prediction model of efficiency and annual energy generation

被引:0
|
作者
Rivera-Martinez, Mario Arturo [1 ]
Garcia-Lopez, Maria Adriana [1 ]
Alanis-Navarro, Jose Andres [1 ,4 ]
Fuentes-Perez, Marcos [2 ]
Lavin-Delgado, Jorge Enrique [3 ]
机构
[1] Univ Politecn Estado Guerrero, Lab Ecotecnol, Taxco De Alarcon, Guerrero, Mexico
[2] Univ Autonoma Estado Morelos, Ctr Invest Ingn & Ciencias Aplicadas, Cuernavaca, Morelos, Mexico
[3] Univ Politecn Estado Guerrero, Dept Redes & Telecomunicac, Taxco De Alarcon, Guerrero, Mexico
[4] Univ Politecn Estado Guerrero, Lab Ecotecnol, Km 105, Taxco De Alarcon 40321, Guerrero, Mexico
关键词
Grid-connected photovoltaic system; GCPVS; PVS performance; PVS efficiency; multivariate regression analysis; Energy3D; PV SYSTEM; TECHNOLOGIES; SIMULATION;
D O I
10.1177/01445987231204394
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this article, the performance of a 3.36 kWp grid-connected photovoltaic system (GCPVS) under warm and subhumid weather conditions and the development of a predictive mathematical model is presented. Climate data of the 2021 year were used to evaluate energy generation, different types of performance, and efficiency. The average annual yield, corrected yield, array, and final yields were 6.45 h/day, 6.18 h/day, 5.16 h/day, and 4.97 h/day, respectively. The overall annual mean capacity factor and efficiency ratios were 20.73% and 77.22%, correspondingly. Experimental data were analyzed and correlated by multivariate linear regression (MLR) prediction and simulation to validate models. The MLR analysis showed that the efficiency is highly dependent on the temperature of the PV modules and that climatic parameters significantly affect the efficiency and output electric power. The prediction models for PV module efficiency, system efficiency, and direct current energy exhibit an uncertainty of +/- 1.04%, +/- 0.57%, and +/- 35.38 kWh, one-to-one. The monthly generation was compared with results obtained by Energy3D simulation-free software, showing an absolute error of +/- 2.33 kWh. This information can be used as a methodological tool for predicting efficiency and power generation in direct current.
引用
收藏
页码:1145 / 1162
页数:18
相关论文
共 50 条
  • [1] Performance Analysis of a Grid-Connected Rooftop Solar Photovoltaic System
    Akpolat, Alper Nabi
    Dursun, Erkan
    Kuzucuoglu, Ahmet Emin
    Yang, Yongheng
    Blaabjerg, Frede
    Baba, Ahmet Fevzi
    ELECTRONICS, 2019, 8 (08)
  • [2] Performance analysis of the first photovoltaic grid-connected system in Algeria
    Bouacha, S.
    Malek, A.
    Benkraouda, O.
    Arab, A. Hadj
    Razagui, A.
    Boulahchiche, S.
    Semaoui, S.
    ENERGY FOR SUSTAINABLE DEVELOPMENT, 2020, 57 : 1 - 11
  • [3] A novel model and experimental validation of dust impact on grid-connected photovoltaic system performance in Northern Oman
    Kazem, Hussein A.
    Chaichan, Miqdam T.
    Al-Waeli, Ali H. A.
    Sopian, K.
    SOLAR ENERGY, 2020, 206 : 564 - 578
  • [4] Research on energy efficiency optimization of grid-connected photovoltaic system based on fuzzy logic
    XinSong
    Zhang, Yan
    Yuan, Chengqing
    2017 4TH INTERNATIONAL CONFERENCE ON TRANSPORTATION INFORMATION AND SAFETY (ICTIS), 2017, : 88 - 91
  • [5] Performance analysis and energy metrics of grid-connected photovoltaic systems
    Ramanan, P.
    Murugavel, Kalidasa K.
    Karthick, A.
    ENERGY FOR SUSTAINABLE DEVELOPMENT, 2019, 52 : 104 - 115
  • [6] Impact of the aging of a photovoltaic module on the performance of a grid-connected system
    Azizi, Amina
    Logerais, Pierre-Olivier
    Omeiri, Amar
    Amiar, Adel
    Charki, Abderafi
    Riou, Olivier
    Delaleux, Fabien
    Durastanti, Jean-Felix
    SOLAR ENERGY, 2018, 174 : 445 - 454
  • [7] Energy and economic efficiency performance assessment of a 28 kWp photovoltaic grid-connected system under desertic weather conditions in Algerian Sahara
    Sahouane, Nordine
    Dabou, Rachid
    Ziane, Abderrezzaq
    Necaibia, Ammar
    Bouraiou, Ahmed
    Rouabhia, Abdelkrim
    Mohammed, Blal
    RENEWABLE ENERGY, 2019, 143 : 1318 - 1330
  • [8] The Analysis Performance of a Grid-Connected 8.2 kWp Photovoltaic System in the Patagonia Region
    Vidal, Humberto
    Rivera, Marco
    Wheeler, Patrick
    Vicencio, Nicolas
    SUSTAINABILITY, 2020, 12 (21) : 1 - 16
  • [9] Optimal sizing of grid-connected photovoltaic energy system in Saudi Arabia
    Ramli, Makbul A. M.
    Hiendro, Ayong
    Sedraoui, Khaled
    Twaha, Ssennoga
    RENEWABLE ENERGY, 2015, 75 : 489 - 495
  • [10] Performance evaluation of parking integrated grid-connected photovoltaic system located in Northern India
    Srivastava, Rachit
    Tiwari, A. N.
    Giri, V. K.
    ENVIRONMENT DEVELOPMENT AND SUSTAINABILITY, 2021, 23 (04) : 5756 - 5775