A linear fiber laser system for measurements of paracetamol concentration is experimentally demonstrated. The cavity is based on a fiber loop mirror and an FBG centered at 1567.8 nm. The sensing head corresponds to a refractometric sensor, whose which principle of operation is based on Fresnel reflection in the fiber tip (FBG side). The system works at detected variations of paracetamol concentrations with a sensitivity of [(8.74 +/- 0.34) x10(-5)] mu W/(g/kg) and a resolution of 2.77 g/kg. The results prove that the fiber laser system could be an asset for processing industries, specifically for non-invasive and real-time measurements of concentration.