Arbitrary Virtual Array Source Aperture (AVASA) Ultrasound Imaging Technique Using Phased Array Excitation

被引:1
作者
Gantala, Thulsiram [1 ]
Gurunathan, Mohan Raj [2 ]
Balasubramaniam, Krishnan [1 ]
机构
[1] Indian Inst Technol Madras, Ctr Nondestruct Evaluat, Dept Mech Engn, Chennai 600036, India
[2] Natl Inst Technol Tiruchirappalli, Dept Phys, Tiruchirappalli 620015, Tamil Nadu, India
关键词
Ultrasonic phase array; Arbitrary virtual array source; FMC-TFM; Beamforming; Ultrasound imaging; SYNTHETIC-APERTURE; TRANSDUCER; OPTIMIZATION;
D O I
10.1007/s10921-023-00985-3
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In this paper, we proposed an advanced ultrasound imaging technique for enhancing the resolution and reducing the imaging processing time by phased array excitement to create beamforming at virtual source positions. In the conventional full matrix capture (FMC) technique, a single element is used for excitation, limiting the transmitted energy and hence reducing the single-to-noise Ratio (SNR) of the received A-scans. The total focusing method (TFM) is implemented on the vast data volume of the received FMC signals to generate virtually focused imaging, requiring high processing time. Therefore, we have introduced two different scanning techniques to increase transmitted energy by exciting the group of the element to form the virtual source below the transducer: (1) virtual array source aperture (VASA) method consists of multiple virtual sources placed below the center of an active aperture with a fixed focal distance. (2) arbitrary virtual array source aperture (AVASA) method consists of multiple virtual sources located randomly below the active aperture. The ultrasound beam is sequentially excited on each virtual source with predefined delay law. While reception, all the transducers are used to form the FMC. The image generation process is similar to the FMC-TFM method. To demonstrate the imaging capabilities of the proposed techniques, we have performed experimentation on two sets of defective specimens with (a) side-drilled holes (SDHs) and (b) cracks. Experimental results quantitatively compared with conventional FMC-TFM, the proposed method improves the SNR by 35% and reduces computation time by 8 times.
引用
收藏
页数:21
相关论文
共 50 条
[41]   MULTI-FOCUS BEAMFORMING FOR THERMAL STRAIN IMAGING USING A SINGLE ULTRASOUND LINEAR ARRAY TRANSDUCER [J].
Nguyen, Man M. ;
Ding, Xuan ;
Leers, Steven A. ;
Kim, Kang .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (06) :1263-1274
[42]   Near-Field 3D SAR Imaging Using a Scanning Linear MIMO Array With Arbitrary Topologies [J].
Fan, Bo ;
Gao, Jing-Kun ;
Li, Hong-Jun ;
Jiang, Zhi-Jie ;
He, Yan .
IEEE ACCESS, 2020, 8 :6782-6791
[43]   High frame rate and high resolution ultrasound imaging with virtual source element in B-mode ultrasound system based on sparse synthetic transmit aperture method [J].
Kim, KS ;
Song, TK .
MEDICAL IMAGING 2004: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2004, 5373 :290-299
[44]   Elevational Synthetic Aperture Focusing for Three-Dimensional Photoacoustic Imaging Using a Clinical One-Dimensional Array Transducer [J].
Yoon, Changhan ;
Kang, Jeeun ;
Song, Tai-Kyong ;
Chang, Jin Ho .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2022, 69 (09) :2817-2825
[45]   Ultrafast 3-D Ultrasound Imaging Using Row-Column Array-Specific Frame-Multiply-and-Sum Beamforming [J].
Hansen-Shearer, Joseph ;
Lerendegui, Marcelo ;
Toulemonde, Matthieu ;
Tang, Meng-Xing .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2022, 69 (02) :480-488
[46]   Wide Field-of-View Plane Wave Ultrasound Imaging based on Linear Array Sub-apertures and Adaptive Weighting Technique [J].
Wang, Yadan ;
Zheng, Chichao ;
Wang, Yuanguo ;
Liu, Mingzhou ;
Peng, Hu .
2022 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS), 2022,
[47]   3-D Super-Resolution Ultrasound Imaging using a 2-D Sparse Array with High Volumetric Imaging Rate [J].
Harput, Sevan ;
Christensen-Jeffries, Kirsten ;
Brown, Jemma ;
Zhu, Jiaqi ;
Zhang, Ge ;
Leow, Chee Hau ;
Toulemonde, Matthieu ;
Ramalli, Alessandro ;
Boni, Enrico ;
Tortoli, Piero ;
Eckersley, Robert J. ;
Dunsby, Chris ;
Tang, Meng-Xing .
2018 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2018,
[48]   Pulse-Echo Ultrasound Imaging Using an AlN Piezoelectric Micromachined Ultrasonic Transducer Array With Transmit Beam-Forming [J].
Lu, Yipeng ;
Tang, Hao-Yen ;
Fung, Stephanie ;
Boser, Bernhard E. ;
Horsley, David A. .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2016, 25 (01) :179-187
[49]   Solar flux distribution study of non-imaging dish concentrator using linear array of triple-junction solar cells scanning technique [J].
Wong, Chee-Woon ;
Chong, Kok-Keong .
SOLAR ENERGY, 2016, 125 :86-98
[50]   Ultrafast 3-D Transcutaneous Super Resolution Ultrasound Using Row-Column Array Specific Coherence-Based Beamforming and Rolling Acoustic Sub-aperture Processing: In Vitro, in Rabbit and in Human Study [J].
Hansen-Shearer, Joseph ;
Yan, Jipeng ;
Lerendegui, Marcelo ;
Huang, Biao ;
Toulemonde, Matthieu ;
Riemer, Kai ;
Tan, Qingyuan ;
Tonko, Johanna ;
Weinberg, Peter D. ;
Dunsby, Chris ;
Tang, Meng-Xing .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2024, 50 (07) :1045-1057