Photon- counting detector coronary CT angiography: impact of virtual monoenergetic imaging and iterative reconstruction on image quality

被引:35
作者
Sartoretti, Thomas [1 ,2 ,3 ]
Mcdermott, Michael [2 ,3 ,4 ]
Mergen, Victor [1 ]
Euler, Andre [1 ]
Schmidt, Bernhard [5 ]
Jost, Gregor [4 ]
Wildberger, Joachim [2 ,3 ]
Alkadhi, Hatem [1 ]
机构
[1] Univ Zurich, Univ Hosp Zurich, Diagnost & Intervent Radiol, Zurich, Switzerland
[2] Maastricht Univ, Dept Radiol & Nucl Med, Med Ctr, Maastricht, Netherlands
[3] Cardiovasc Res Inst Maastricht CARIM, Maastricht, Netherlands
[4] Bayer AG, Berlin, Germany
[5] Siemens Healthineers, Forchheim, Germany
关键词
Computed Tomography Angiography; Coronary Vessels; Photons; Phantoms; Imaging; COMPUTED-TOMOGRAPHY; CONTRAST-MEDIA; STENOSIS; PHANTOM;
D O I
10.1259/bjr.20220466
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To assess the impact of low kilo-electronvolt (keV) virtual monoenergetic image (VMI) energies and iterative reconstruction on image quality of clinical photon-counting detector coronary CT angiography (CCTA).Methods: CCTA with PCD- CT (prospective ECG -triggering, 120 kVp, automatic tube current modulation) was performed in a high -end cardiovascular phantom with dynamic flow, pulsatile heart motion, and including different calcified plaques with various stenosis grades and in 10 consecutive patients. VMI at 40,50,60 and 70 keV were reconstructed without (QIR- off) and with all quantum iterative reconstruction (QIR) levels (QIR- 1 to 4). In the phantom, noise power spectrum, vessel atten-uation, contrast - to-noise -ratio (CNR), and vessel sharp-ness were measured. Two readers graded stenoses in the phantom and graded overall image quality, subjective noise, vessel sharpness, vascular contrast, and coronaryartery plaque delineation on 5 -point Likert scales in patients.Results: In the phantom, noise texture was only slightly affected by keV and QIR while noise increased by 69% from 70 keV QIR- 4 to 40 keV QIR- off. Reconstructions at 40 keV QIR- 4 exhibited the highest CNR (46.1 +/- 1.8), vessel sharpness (425 +/- 42 increment HU/mm), and vessel atten-uation (1098 +/- 14 HU). Stenosis measurements were not affected by keV or QIR level (p > 0.12) with an average error of 3%/6% for reader 1/reader 2, respectively. In patients, across all subjective categories and both readers, 40 keV QIR- 3 and QIR- 4 images received the best scores (p < 0.001).Conclusion: Forty keV VMI with QIR- 4 significantly improved image quality of CCTA with PCD- CT. Advances in knowledge: PCD- CT at 40 keV and QIR- 4 improves image quality of CCTA.
引用
收藏
页数:11
相关论文
共 38 条
[1]   Comprehensive Comparison of Virtual Monoenergetic and Linearly Blended Reconstruction Techniques in Third-Generation Dual-Source Dual-Energy Computed Tomography Angiography of the Thorax and Abdomen [J].
Albrecht, Moritz H. ;
Trommer, Jesko ;
Wichmann, Julian L. ;
Scholtz, Jan-Erik ;
Martin, Simon S. ;
Lehnert, Thomas ;
Vogl, Thomas J. ;
Bodelle, Boris .
INVESTIGATIVE RADIOLOGY, 2016, 51 (09) :582-590
[2]   Improved coronary artery contrast enhancement using noise-optimised virtual monoenergetic imaging from dual-source dual-energy computed tomography [J].
Arendt, Christophe T. ;
Czwikla, Rouben ;
Lenga, Lukas ;
Wichmann, Julian L. ;
Albrecht, Moritz H. ;
Booz, Christian ;
Martin, Simon S. ;
Leithner, Doris ;
Tischendorf, Patricia ;
Blandino, Alfredo ;
Vogl, Thomas J. ;
D'Angelo, Tommaso .
EUROPEAN JOURNAL OF RADIOLOGY, 2020, 122
[3]   Visualization of bone details in a novel photon-counting dual-source CT scanner-comparison with energy-integrating CT [J].
Bette, Stefanie J. ;
Braun, Franziska M. ;
Haerting, Mark ;
Decker, Josua A. ;
Luitjens, Jan H. ;
Scheurig-Muenkler, Christian ;
Kroencke, Thomas J. ;
Schwarz, Florian .
EUROPEAN RADIOLOGY, 2022, 32 (05) :2930-2936
[4]   First In-Human Results of Computed Tomography Angiography for Coronary Stent Assessment With a Spectral Photon Counting Computed Tomography [J].
Boccalini, Sara ;
Si-Mohamed, Salim A. ;
Lacombe, Hugo ;
Diaw, Adja ;
Varasteh, Mohammad ;
Rodesch, Pierre-Antoine ;
Villien, Marjorie ;
Sigovan, Monica ;
Dessouky, Riham ;
Coulon, Philippe ;
Yagil, Yoad ;
Lahoud, Elias ;
Erhard, Klaus ;
Rioufol, Gilles ;
Finet, Gerard ;
Bonnefoy-Cudraz, Eric ;
Bergerot, Cyrille ;
Boussel, Loic ;
Douek, Philippe C. .
INVESTIGATIVE RADIOLOGY, 2022, 57 (04) :212-221
[5]   Intravenous contrast material administration at helical 16-detector row CT coronary angiography: Effect of iodine concentration on vascular attenuation [J].
Cademartiri, F ;
Mollet, NR ;
van der Lugt, A ;
McFadden, EP ;
Stijnen, T ;
de Feyter, PJ ;
Krestin, GP .
RADIOLOGY, 2005, 236 (02) :661-665
[6]   Contrast media injection protocol optimization for dual-energy coronary CT angiography: results from a circulation phantom [J].
De Santis, Domenico ;
Caruso, Damiano ;
Schoepf, U. Joseph ;
Eid, Marwen ;
Albrecht, Moritz H. ;
Duguay, Taylor M. ;
Varga-Szemes, Akos ;
Laghi, Andrea ;
De Cecco, Carlo N. .
EUROPEAN RADIOLOGY, 2018, 28 (08) :3473-3481
[7]   Low-dose CT of the abdomen: Initial experience on a novel photon-counting detector CT and comparison with energy-integrating detector CT [J].
Decker, Josua A. ;
Bette, Stefanie ;
Lubina, Nora ;
Rippel, Katharina ;
Braun, Franziska ;
Risch, Franka ;
Wollny, Claudia ;
Scheurig-Muenkler, Christian ;
Kroencke, Thomas J. ;
Schwarz, Florian .
EUROPEAN JOURNAL OF RADIOLOGY, 2022, 148
[8]   High-Pitch Photon-Counting Detector Computed Tomography Angiography of the Aorta Intraindividual Comparison to Energy-Integrating Detector Computed Tomography at Equal Radiation Dose [J].
Euler, Andre ;
Higashigaito, Kai ;
Mergen, Victor ;
Sartoretti, Thomas ;
Zanini, Bettina ;
Schmidt, Bernhard ;
Flohr, Thomas G. ;
Ulzheimer, Stefan ;
Eberhard, Matthias ;
Alkadhi, Hatem .
INVESTIGATIVE RADIOLOGY, 2022, 57 (02) :115-121
[9]   Optimizing radiation dose by using advanced modelled iterative reconstruction in high-pitch coronary CT angiography [J].
Gordic, Sonja ;
Desbiolles, Lotus ;
Sedlmair, Martin ;
Manka, Robert ;
Plass, Andre ;
Schmidt, Bernhard ;
Husarik, Daniela B. ;
Maisano, Francesco ;
Wildermuth, Simon ;
Alkadhi, Hatem ;
Leschka, Sebastian .
EUROPEAN RADIOLOGY, 2016, 26 (02) :459-468
[10]   Assessment of an Advanced Image-Based Technique to Calculate Virtual Monoenergetic Computed Tomographic Images From a Dual-Energy Examination to Improve Contrast-To-Noise Ratio in Examinations Using Iodinated Contrast Media [J].
Grant, Katharine L. ;
Flohr, Thomas G. ;
Krauss, Bernhard ;
Sedlmair, Martin ;
Thomas, Christoph ;
Schmidt, Bernhard .
INVESTIGATIVE RADIOLOGY, 2014, 49 (09) :586-592