Characterization of Ethos therapy systems for adaptive radiation therapy: A multi-machine comparison

被引:3
|
作者
van de Schoot, Agustinus J. [1 ,3 ]
Hoffmans, Daan [2 ]
van Ingen, Karel M. [1 ]
Simons, Martijn J. [2 ]
Wiersma, Jan [1 ]
机构
[1] Univ Amsterdam, Med Ctr, locat Univ Amsterdam, Dept Radiat Oncol, Amsterdam, Netherlands
[2] Univ Amsterdam, Med Ctr, locat Vrije Univ Amsterdam, Dept Radiat Oncol, Amsterdam, Netherlands
[3] Univ Amsterdam, Med Ctr, locat Univ Amsterdam, Dept Radiat Oncol, Meibergdreef 9, NL-1105 AZ Amsterdam, Netherlands
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2023年 / 24卷 / 05期
关键词
adaptive radiotherapy; beam characterization; machine commissioning; quality assurance; PLAN SELECTION STRATEGY; QUALITY-ASSURANCE; CLINICAL IMPLEMENTATION; RADIOTHERAPY; PHOTON;
D O I
10.1002/acm2.13905
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeThe recently released Ethos therapy system (Varian Medical Systems) allows for online CBCT-guided adaptive radiation therapy (RT). The clinical introduction of multiple systems requires machine characterization and machine variation quantification to allow patient interchangeability between systems. Despite several clinical introductions, limited vendor-independent information on machine performance is available. Our aim was to determine the relevant dosimetric and mechanical characteristics of individual machines and to quantify machine variations. MethodsSix Ethos treatment machines, equipped with a 6-MV FFF beam including dual-layer MLC and kV-CBCT system, were recently introduced clinically after extensive machine characterization and pre-configured beam model verification. Point doses and profiles were measured and compared to vendor-provided reference data and dose calculations. Also, dose calculations were verified based on point measurements for non-standard fields and dose distributions for optimized treatment plans. Agreements between dose profiles (dose distributions) were quantified using 1D (3D) gamma-analysis. Additionally, we quantified leaf transmission, dosimetric leaf gap (DLG) and couch attenuation, determined isocenter accuracy and kV-MV isocenter coincidence and verified the kV-CBCT system. Machine variations were quantified for all dosimetric and mechanical characteristics. ResultsFor all machines, distinct agreements were found between measurements and vendor-provided reference data as well as measurements and dose calculations. Mean gamma(1%/1mm) values for all profiles were below 0.30. All profiles, point measurements and dose distributions matched well among the six machines. Minimal machine variations were found in terms of DLG (0.05 mm), leaf transmission (0.001%), isocenter accuracy (0.08 mm), kV-MV isocenter coincidence (0.15 mm), couch attenuation (0.69%), and CBCT imaging dose (0.29 mGy). ConclusionsThis study demonstrates excellent agreement between individual Ethos therapy systems and vendor-provided reference data as well as a pre-configured beam model. Furthermore, our results show good consistency among all machines and provide valuable insights on relevant machine characteristics. The systematically obtained results provide benchmark data for future clinical introduction of Ethos therapy systems.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Framework for the quantitative assessment of adaptive radiation therapy protocols
    Weppler, Sarah
    Quon, Harvey
    Banerjee, Robyn
    Schinkel, Colleen
    Smith, Wendy
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (06): : 26 - 34
  • [2] Dosimetric characterization of foam padding with posterior fields in palliative radiation therapy
    Fagerstrom, Jessica M.
    MEDICAL DOSIMETRY, 2024, 49 (02) : 65 - 68
  • [3] Multi-institutional comparison of computer-based independent dose calculation for intensity modulated radiation therapy and volumetric modulated arc therapy
    Kamima, Tatsuya
    Baba, Hiromi
    Takahashi, Ryo
    Yamashita, Mikiko
    Sugawara, Yasuharu
    Kawai, Daisuke
    Yamamoto, Toshijiro
    Satou, Aya
    Tachibana, Hidenobu
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 45 : 72 - 81
  • [4] Online Adaptive Radiation Therapy
    Lim-Reinders, Stephanie
    Keller, Brian M.
    Al-Ward, Shahad
    Sahgal, Arjun
    Kim, Anthony
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (04): : 994 - 1003
  • [5] Pan-Canadian assessment of image guided adaptive radiation therapy and the role of the radiation therapist
    Moreira, Amanda
    Rosewall, Tara
    Tsang, Yat
    Lindsay, Patricia
    Chung, Peter
    Li, Winnie
    TECHNICAL INNOVATIONS & PATIENT SUPPORT IN RADIATION ONCOLOGY, 2025, 33
  • [6] Adaptive Radiation Therapy (ART) Strategies and Technical Considerations: A State of the ART Review From NRG Oncology
    Glide-Hurst, Carri K.
    Lee, Percy
    Yock, Adam D.
    Olsen, Jeffrey R.
    Cao, Minsong
    Siddiqui, Farzan
    Parker, William
    Doemer, Anthony
    Rong, Yi
    Kishan, Amar U.
    Benedict, Stanley H.
    Li, X. Allen
    Erickson, Beth A.
    Sohn, Jason W.
    Xiao, Ying
    Wuthrick, Evan
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2021, 109 (04): : 1054 - 1075
  • [7] Radiation Therapy Quality Assurance Tasks and Tools: The Many Roles of Machine Learning
    Kalet, Alan M.
    Luk, Samuel M. H.
    Phillips, Mark H.
    MEDICAL PHYSICS, 2020, 47 (05) : E168 - E177
  • [8] Adaptive Radiation Therapy in the Treatment of Lung Cancer: An Overview of the Current State of the Field
    Piperdi, Huzaifa
    Portal, Daniella
    Neibart, Shane S.
    Yue, Ning J.
    Jabbour, Salma K.
    Reyhan, Meral
    FRONTIERS IN ONCOLOGY, 2021, 11
  • [9] Developing quality assurance processes for image-guided adaptive radiation therapy
    Yan, Di
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (01): : S28 - S32
  • [10] Multi-institutional Comparison of Intensity Modulated Radiation Therapy (IMRT) Planning Strategies and Planning Results for Nasopharyngeal Cancer
    Park, Sung Ho
    Park, Hee Chul
    Park, Suk Won
    Oh, Do Hoon
    Choi, Youngmin
    Kim, Jeung Kee
    Ahn, Yong Chan
    Park, Won
    Suh, Hyun Sook
    Lee, Rena
    Bae, Hoonsik
    JOURNAL OF KOREAN MEDICAL SCIENCE, 2009, 24 (02) : 248 - 255