Novel conformable stent-graft repair of abdominal aortic aneurysms with hostile neck anatomy: A single-centre experience

被引:5
|
作者
Lee, Seong Hoon [1 ]
Melvin, Ross [1 ]
Kerr, Stacey [1 ]
Barakova, Lucie [2 ]
Wilson, Alasdair [1 ]
Renwick, Bryce [1 ]
机构
[1] NHS Grampian, Dept Vasc Surg, Aberdeen Royal Infirm, Aberdeen, Scotland
[2] Univ Aberdeen, Sch Med, Inst Appl Hlth Sci, Aberdeen, Scotland
关键词
Abdominal aortic aneurysms; endovascular procedures; endovascular aneurysm repair; hostile neck; vascular surgical procedure; OUTCOMES; AAA;
D O I
10.1177/17085381221124990
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objectives Abdominal aortic aneurysms (AAAs) demonstrating hostile neck anatomy (HNA) are associated with increased perioperative risk and mortality. A number of these patients are not suitable for standard endovascular aneurysm repair (EVAR) and are high risk for open surgery. We present our experience with the first implantations in Scotland of a novel conformable aortic stent-graft designed to overcome some of the challenges of HNAs. Methods From May 2018 to March 2022, 24 consecutive patients with non-ruptured AAAs demonstrating HNAs (neck length < 15 mm, or angulation > 60 degrees) were treated with GORE Excluder Conformable AAA endoprosthesis (CLEVAR) (CEXC Device, W.L. Gore and Associates, Flagstaff, AZ, USA) at a Scottish vascular centre. We assessed clinical outcomes and technical success of CLEVAR during deployment, primary admission and the post-operative period at 3- and 12-month clinical follow-up alongside CT angiography. Results Twenty-four patients (20 males, mean age 75.6) were included. Primary technical success of proximal seal zones and CLEVAR deployment (no type 1/3 endoleaks, no conversion to open repair, AAA excluded and patient leaving theatre alive) was achieved in 100% of patients. All patients were alive and clinically stable at 3- and 12-month follow-up. There were five patients requiring re-intervention; at the 3-month follow-up, one patient (4.2%) developed a type 1b endoleak requiring graft limb extension, one patient developed a right common femoral artery dissection requiring open repair and one patient required a limb extension of the right iliac limb due to risk of developing a type 1b endoleak. At the 12-month follow-up, two patients required embolization of type 2 endoleaks and no patients demonstrated type 1 or type 3 endoleaks. Conclusions: In-hospital and post-operative 3- and 12-month clinical and angiographic outcomes demonstrate safety and efficacy with CLEVARs in treating unruptured AAAs with HNA. Further research involving larger heterogenous sample sizes is warranted to determine long-term clinical outcomes.
引用
收藏
页码:19 / 24
页数:6
相关论文
共 50 条
  • [21] Ventana Fenestrated Stent-Graft System for Endovascular Repair of Juxtarenal Aortic Aneurysms
    Mertens, Renato
    Bergoeing, Michel
    Marine, Leopoldo
    Valdes, Francisco
    Kraemer, Albrecht
    Vergara, Jeanette
    JOURNAL OF ENDOVASCULAR THERAPY, 2012, 19 (02) : 173 - 178
  • [22] Impact of Stent-Graft Oversizing on Gutter Areas after Chimney Graft Repair for Complex Abdominal Aortic Aneurysms
    de Blic, Romain
    Cochennec, Frederic
    Alomran, Faris
    Kobeiter, Hicham
    Allaire, Eric
    Desgranges, Pascal
    Becquemin, Jean-Pierre
    ANNALS OF VASCULAR SURGERY, 2018, 51 : 200 - 206
  • [23] A single-centre experience of the treatment of ruptured abdominal aortic aneurysms: clinical and anatomic characteristics of open versus endovascular repair
    Ioannidis, O.
    Trellopoulos, G.
    Tamouridis, G.
    Konstantinidis, K.
    Megalopoulos, A.
    INTERNATIONAL ANGIOLOGY, 2012, 31 (04) : 386 - 392
  • [24] Juxtarenal aortic aneurysms: preliminary experience with fenestrated E-vita abdominal stent-graft
    Ricci, C.
    Ceccherini, C.
    Cini, M.
    Vigni, F.
    Leonini, S.
    Puliti, A.
    Benvenuti, A.
    Tucci, E.
    Tommasino, G.
    Muzzi, L.
    Neri, E.
    JOURNAL OF CARDIOVASCULAR SURGERY, 2013, 54 (04) : 491 - 497
  • [25] Are abdominal aortic aneurysms with hostile neck really unsuitable for EVAR? Our experience
    Cerini, Paolo
    Guzzardi, Giuseppe
    Divenuto, Ignazio
    Parziale, Giuseppe
    Brustia, Piero
    Carriero, Alessandro
    Fossaceca, Rita
    RADIOLOGIA MEDICA, 2016, 121 (06): : 528 - 535
  • [26] Endovascular stent-graft repair of spontaneous aorto-caval fistula secondary to a ruptured abdominal aortic aneurysm: An emergency management of hostile anatomy
    Liu, Mingyuan
    Wang, Haofu
    SAGE OPEN MEDICAL CASE REPORTS, 2016, 4
  • [27] Impact of stent-graft complexity on mid-term results in fenestrated endovascular aortic repair of juxtarenal and suprarenal abdominal aortic aneurysms
    Yazar, Ozan
    Pilz da Cunha, Gabriela
    de Haan, Michiel W.
    Mees, Barend M.
    Schurink, Geert W.
    JOURNAL OF CARDIOVASCULAR SURGERY, 2023, 64 (03) : 268 - 278
  • [28] Endurant Stent-Graft: A 2-Year, Single-Center Experience With a New Commercially Available Device for the Treatment of Abdominal Aortic Aneurysms
    Troisi, Nicola
    Torsello, Giovanni
    Donas, Konstantinos P.
    Austermann, Martin
    JOURNAL OF ENDOVASCULAR THERAPY, 2010, 17 (03) : 439 - 448
  • [29] Initial single-site experience with the Ovation abdominal stent-graft system in patients with challenging aortoiliac anatomy
    Irace, Luigi
    Venosi, Stefano
    Gattuso, Roberto
    Laurito, Antonella
    Pompa, Valentina
    Pasinati, Giacomo
    Bresadola, Luciano
    JOURNAL OF CARDIOVASCULAR SURGERY, 2016, 57 (06) : 846 - 852
  • [30] Single-center Experience of Endovascular Abdominal Aortic Aneurysm Treatment in Patients with Hostile Neck Anatomy versus Favorable Anatomy
    Montes Carmona, Melisa
    Carbajal Contreras, Gustavo
    Murillo Barrios, Ivn Enrique
    Sanchez Escalante, Luis Ricardo
    GACETA MEDICA DE MEXICO, 2014, 150 : 306 - 310