Labeling of Mucin-Type O-Glycans for Quantification Using Liquid Chromatography and Fluorescence Detection

被引:7
作者
Safferthal, Marc [1 ,2 ]
Bechtella, Leila [1 ,2 ]
Zappe, Andreas [1 ,2 ]
Vos, Gael M. [1 ,2 ]
Pagel, Kevin [1 ,2 ]
机构
[1] Fritz Haber Inst Max Planck Soc, D-14195 Berlin, Germany
[2] Free Univ Berlin, Dept Biol Chem Pharm, D-14195 Berlin, Germany
来源
ACS MEASUREMENT SCIENCE AU | 2024年 / 4卷 / 02期
关键词
mucin-type O-glycans; labeling; quantification; fluorescence detection; hydrophilicinteraction liquid chromatography; mass spectrometry; BOVINE SUBMAXILLARY MUCIN; SAMPLE PREPARATION METHOD; SERUM N-GLYCANS; MASS-SPECTROMETRY; GASTRIC MUCIN; NEUTRAL OLIGOSACCHARIDES; OXIDATIVE RELEASE; DATABASE; GLYCOSYLATION; IDENTIFICATION;
D O I
10.1021/acsmeasuresciau.3c00071
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
O-glycosylation is a common post-translational modification that is essential for the defensive properties of mucus barriers. Incomplete and altered O-glycosylation is often linked to severe diseases, such as cancer, cystic fibrosis, and chronic obstructive pulmonary disease. Originating from a nontemplate-driven biosynthesis, mucin-type O-glycan structures are very complex. They are often present as heterogeneous mixtures containing multiple isomers. Therefore, the analysis of complex O-glycan mixtures usually requires hyphenation of orthogonal techniques such as liquid chromatography (LC), ion mobility spectrometry, and mass spectrometry (MS). However, MS-based techniques are mainly qualitative. Moreover, LC separation of O-glycans often lacks reproducibility and requires sophisticated data treatment and analysis. Here we present a mucin-type O-glycomics analysis workflow that utilizes hydrophilic interaction liquid chromatography for separation and fluorescence labeling for detection and quantification. In combination with mass spectrometry, a detailed analysis on the relative abundance of specific mucin-type O-glycan compositions and features, such as fucose, sialic acids, and sulfates, is performed. Furthermore, the average number of monosaccharide units of O-glycans in different samples was determined. To demonstrate universal applicability, the method was tested on mucins from different tissue types and mammals, such as bovine submaxillary mucins, porcine gastric mucins, and human milk mucins. To account for day-to-day retention time shifts in O-glycan separations and increase the comparability between different instruments and laboratories, we included fluorescently labeled dextran ladders in our workflow. In addition, we set up a library of glucose unit values for all identified O-glycans, which can be used to simplify the identification process of glycans in future analyses.
引用
收藏
页码:223 / 230
页数:8
相关论文
共 50 条
  • [41] Development and validation of a sensitive quantification method for hematoporphyrin monomethyl ether in plasma using high-performance liquid chromatography with fluorescence detection
    Li, Peng
    Sun, Jian-guo
    Huang, Chen-rong
    Pan, Guo-Yu
    Xu, Mei-juan
    Li, Jing
    Wang, Guang-ji
    Tao, Ji-ning
    BIOMEDICAL CHROMATOGRAPHY, 2006, 20 (12) : 1277 - 1282
  • [42] Determination of fatty acids by high-performance liquid chromatography and fluorescence detection using precolumn derivatization with 9-fluorenylmethyl chloroformate
    Majnooni, Mohammad Bagher
    Mohammadi, Bahareh
    Jalili, Ronak
    Babaei, Atefeh
    Bahrami, Gholamreza
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2016, 39 (19-20) : 877 - 881
  • [43] High-Performance Liquid Chromatography Using UV Detection for the Simultaneous Quantification of Ropivacaine and Bupivacaine in Human Plasma
    Gaudreault, Francois
    Drolet, Pierre
    Varin, France
    THERAPEUTIC DRUG MONITORING, 2009, 31 (06) : 753 - 757
  • [44] Quantification of amyloid fibrils using size exclusion chromatography coupled with online fluorescence and ultraviolet detection
    Randrianjatovo-Gbalou, Irina
    Marcato-Romain, Claire-Emmanuelle
    Girbal-Neuhauser, Elisabeth
    ANALYTICAL BIOCHEMISTRY, 2015, 488 : 19 - 21
  • [45] Simultaneous screening of homotaurine and taurine in marine macro-algae using liquid chromatography-fluorescence detection
    Mehdinia, Ali
    Rostami, Simindokht
    Dadkhah, Sahar
    Fumani, Neda Sheijooni
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2017, 14 (10) : 2135 - 2142
  • [46] Simultaneous Determination of the Residues of Fourteen Quinolones and Fluoroquinolones in Fish Samples using Liquid Chromatography with Photometric and Fluorescence Detection
    Canada-Canada, Florentina
    Espinosa-Mansilla, Anunciacion
    Jimenez Giron, Ana
    Munoz de la Pena, Arsenio
    CZECH JOURNAL OF FOOD SCIENCES, 2012, 30 (01) : 74 - 82
  • [47] Determination of urea using high-performance liquid chromatography with fluorescence detection after automated derivatisation with xanthydrol
    Clark, Shona
    Francis, Paul S.
    Conlan, Xavier A.
    Barnett, Neil W.
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1161 (1-2) : 207 - 213
  • [48] Combined Quantification and Characterization of Dissolved Organic Matter by Liquid Chromatography-Mass Spectrometry Using Charged Aerosol Detection
    Felgate, Stacey L.
    Jakobsson, Elizabeth
    Subieta, Andrea Balderrama
    Tranvik, Lars J.
    Hawkes, Jeffrey A.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2024, 35 (12) : 2910 - 2917
  • [49] Using high-performance liquid chromatography/mass spectrometry for the quantification of plasma phospholipids in children with type 1 diabetes
    V. A. Akmurzina
    E. E. Petryaikina
    S. V. Saveliev
    A. A. Selishcheva
    Journal of Analytical Chemistry, 2013, 68 : 1170 - 1177
  • [50] Ionic liquid-dispersive liquid-liquid microextraction for the simultaneous determination of pesticides and metabolites in soils using high-performance liquid chromatography and fluorescence detection
    Asensio-Ramos, Maria
    Hernandez-Borges, Javier
    Borges-Miguel, Teresa M.
    Angel Rodriguez-Delgado, Miguel
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (30) : 4808 - 4816