Dosimetry audit in advanced radiotherapy using in-house developed anthropomorphic head & neck phantom

被引:2
作者
Kakade, Nitin R. [1 ]
Kumar, Rajesh [1 ]
Sharma, S. D. [1 ,2 ]
Sapra, B. K. [1 ,2 ]
机构
[1] Bhabha Atom Res Ctr, Radiol Phys & Advisory Div, Mumbai 400094, India
[2] Homi Bhabha Natl Inst, Mumbai 400094, India
关键词
dosimetry audit; radiotherapy; anthropomorphic phantom; thermoluminescent dosimeters; MODULATED RADIATION-THERAPY; DESIGN; IMPLEMENTATION; VERIFICATION; CANCER;
D O I
10.1088/2057-1976/ad222a
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The treatment of head and neck (H&N) cancer presents formidable challenges due to the involvement of normal tissue and organs at risk (OARs) in the close vicinity. Ensuring the precise administration of the prescribed dose demands prior dose verification. Considering contour irregularity and heterogeneity in the H&N region, an anthropomorphic and heterogeneous H&N phantom was developed and fabricated locally for conducting the dosimetry audit in advanced radiotherapy treatments. This specialized phantom emulates human anatomy and incorporates a removable cylindrical insert housing a C-shaped planning target volume (PTV) alongside key OARs including the spinal cord, oral cavity, and bilateral parotid glands. Acrylonitrile Butadiene Styrene (ABS) was chosen for PTV and parotid fabrication, while Delrin was adopted for spinal cord fabrication. A pivotal feature of this phantom is the incorporation of thermoluminescent dosimeters (TLDs) within the PTV and OARs, enabling the measurement of delivered dose. To execute the dosimetry audit, the phantom, accompanied by dosimeters and comprehensive guidelines, was disseminated to multiple radiotherapy centers. Subsequently, hospital physicists acquired computed tomography (CT) scans to generate treatment plans for phantom irradiation. The treatment planning system (TPS) computed the anticipated dose distribution within the phantom, and post-irradiation TLD readings yielded actual dose measurements. The TPS calculated and TLD measured dose values at most of the locations inside the PTV were found comparable within +/- 4%. The outcomes affirm the suitability of the developed anthropomorphic H&N phantom for precise dosimetry audits of advanced radiotherapy treatments.
引用
收藏
页数:10
相关论文
共 24 条
[1]   TLD and OSLD dosimetry systems for remote audits of radiotherapy external beam calibration [J].
Alvarez, P. ;
Kry, S. F. ;
Stingo, F. ;
Followill, D. .
RADIATION MEASUREMENTS, 2017, 106 :412-415
[2]   Cancer and Radiation Therapy: Current Advances and Future Directions [J].
Baskar, Rajamanickam ;
Lee, Kuo Ann ;
Yeo, Richard ;
Yeoh, Kheng-Wei .
INTERNATIONAL JOURNAL OF MEDICAL SCIENCES, 2012, 9 (03) :193-199
[3]  
Branco Daniela, 2018, Int J Part Ther, V4, P40, DOI [10.14338/ijpt-17-00005.1, 10.14338/IJPT-17-00005.1]
[4]   A national dosimetric audit of IMRT [J].
Budgell, Geoff ;
Berresford, Joe ;
Trainer, Michael ;
Bradshaw, Ellie ;
Sharpe, Peter ;
Williams, Peter .
RADIOTHERAPY AND ONCOLOGY, 2011, 99 (02) :246-252
[5]   Examining credentialing criteria and poor performance indicators for IROC Houston's anthropomorphic head and neck phantom [J].
Carson, Mallory E. ;
Molineu, Andrea ;
Taylor, Paige A. ;
Followill, David S. ;
Stingo, Francesco C. ;
Kry, Stephen F. .
MEDICAL PHYSICS, 2016, 43 (12) :6491-6496
[6]   Dosimetry audit for a multi-centre IMRT head and neck trial [J].
Clark, Catharine H. ;
Hansen, Vibeke Nordmark ;
Chantler, Hannah ;
Edwards, Craig ;
James, Hayley V. ;
Webster, Gareth ;
Miles, Elizabeth A. ;
Urbano, M. Teresa Guerrero ;
Bhide, Shree A. ;
Bidmead, A. Margaret ;
Nutting, Christoper M. .
RADIOTHERAPY AND ONCOLOGY, 2009, 93 (01) :102-108
[7]   Intensity-modulated radiation therapy in the treatment of head and neck cancer [J].
Eisbruch, A .
NATURE CLINICAL PRACTICE ONCOLOGY, 2005, 2 (01) :34-39
[8]   IMRT commissioning: Multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119 [J].
Ezzell, Gary A. ;
Burmeister, Jay W. ;
Dogan, Nesrin ;
LoSasso, Thomas J. ;
Mechalakos, James G. ;
Mihailidis, Dimitris ;
Molineu, Andrea ;
Palta, Jatinder R. ;
Ramsey, Chester R. ;
Salter, Bill J. ;
Shi, Jie ;
Xia, Ping ;
Yue, Ning J. ;
Xiao, Ying .
MEDICAL PHYSICS, 2009, 36 (11) :5359-5373
[9]   Design, manufacture, and evaluation of an anthropomorphic pelvic phantom purpose-built for radiotherapy dosimetric intercomparison [J].
Harrison, K. M. ;
Ebert, M. A. ;
Kron, T. ;
Howlett, S. J. ;
Cornes, D. ;
Hamilton, C. S. ;
Denham, J. W. .
MEDICAL PHYSICS, 2011, 38 (10) :5330-5337
[10]   Intensity-modulated radiation therapy:: emerging cancer treatment technology [J].
Hong, TS ;
Ritter, MA ;
Tomé, WA ;
Harari, PM .
BRITISH JOURNAL OF CANCER, 2005, 92 (10) :1819-1824