Ability to remotely monitor atrial high-rate episodes using a single-chamber implantable cardioverter-defibrillator with a floating atrial sensing dipole

被引:8
作者
Hindricks, Gerhard [1 ]
Theuns, Dominic A. [2 ]
Bar-Lev, David [3 ]
Anguera, Ignasi [4 ]
Ayala Paredes, Felix Alejandro [5 ]
Arnold, Martin [6 ]
Geller, J. Christoph [7 ]
Merkely, Bela [8 ]
Dyrda, Katia Marjolaine [9 ]
Perings, Christian [10 ]
Maglia, Giampiero [11 ]
Ploux, Sylvain [12 ]
Meyhoefer, Juergen [13 ]
Blomstroem-Lundqvist, Carina [14 ,15 ]
Karjalainen, Pasi [16 ]
Liang, Yanchun [17 ]
Diemberger, Igor [18 ]
Wranicz, Jerzy Krzysztof [19 ]
Barr, Craig [20 ]
Quartieri, Fabio [21 ]
Timmel, Tobias [22 ]
Bollmann, Andreas [22 ]
机构
[1] Heart Ctr Leipzig & Leipzig Heart Inst, Dept Elect, Strumpellstr 39, D-04289 Leipzig, Germany
[2] Erasmus MC, S Gravendijkwal 230, NL-3015 GD Rotterdam, Netherlands
[3] Chaim Sheba Med Ctr, IL-52621 Tel Hashomer, Israel
[4] Bellvitge Univ Hosp, Heart Dis Inst, Bellvitge Biomed Res Inst IDIBELL, Arrhythmia Unit, Barcelona, Spain
[5] Sherbrooke Univ Hosp CHUS, 3001 12E Ave Nord, Sherbrooke, PQ J1H 5N4, Canada
[6] Friedrich Alexander Univ Erlangen Nuremberg, Dept Cardiol, Ulmenweg 18, D-91054 Erlangen, Germany
[7] Zentralklin Bad Berka GmbH, Robert Koch Allee 9, D-99437 Bad Berka, Germany
[8] Semmelweis Univ, Varosmajorutca 68, H-1122 Budapest, Hungary
[9] Univ Montreal, Montreal Heart Inst, 5000 Rue Belanger, Montreal, PQ H1T IC8, Canada
[10] St Marien Hosp GmbH, Altstadtstr 23, D-44534 Lunen, Germany
[11] Azienda Osped Pugliese Ciaccio, Via Vinicio Cortese 25, I-88100 Catanzaro, Italy
[12] Hop Haut Leveque CHU, 1 Ave Magellan, F-33600 Pessac, France
[13] Maria Heimsuchung Caritas Klin Pankow, Breite Str 46 47, D-13187 Berlin, Germany
[14] Orebro Univ, Sch Med Sci, Fac Med & Hlth, Dept Cardiol, SE-70182 Orebro, Sweden
[15] Uppsala Univ, Dept Med Sci & Cardiol, S-75185 Uppsala, Sweden
[16] Satakunta Cent Hosp, Sairaalantie 3, Pori 28500, Finland
[17] Gen Hosp Northern Theater Command, 83 Wenhua Rd, Shenyang 110016, Peoples R China
[18] Univ Bologna, Inst Cardiol, Dept Expt Diagnost & Specialty Med, Via Massarenti 9, I-40138 Bologna, Italy
[19] Med Univ Lodz, Dept Elect, Ul Pomorska 251, PL-92213 Lodz, Poland
[20] Russells Hall Hosp, Pensett Rd, Dudley DY1 2HQ, England
[21] Arcispedale Santa Maria Nuova, Viale Risorgimento 80, I-42123 Reggio Emilia, Italy
[22] Biotron SE & Co KG, Woermannkehre 1, D-12359 Berlin, Germany
来源
EUROPACE | 2023年 / 25卷 / 05期
关键词
Single-lead ICD with atrial sensing; DX ICD; Atrial fibrillation; AHRE; Remote monitoring; Risk of stroke; FIBRILLATION; LEAD;
D O I
10.1093/europace/euad061
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims To allow timely initiation of anticoagulation therapy for the prevention of stroke, the European guidelines on atrial fibrillation (AF) recommend remote monitoring (RM) of device-detected atrial high-rate episodes (AHREs) and progression of arrhythmia duration along pre-specified strata (6 min...<1h, 1 h...<24 h, >= 24h). We used the MATRIX registry data to assess the capability of a single-lead implantable cardioverter-defibrillator (ICD) with atrial sensing dipole (DX ICD system) to follow this recommendation in patients with standard indication for single-chamber ICD. Methods and results In 1841 DX ICD patients with daily automatic RM transmissions, electrograms of first device-detected AHREs per patient in each duration stratum were adjudicated, and the corresponding positive predictive values (PPVs) for the detections to be true atrial arrhythmia were calculated. Moreover, the incidence and progression of new-onset AF was assessed in 1451 patients with no AF history. A total of 610 AHREs >= 6min were adjudicated. The PPV was 95.1% (271 of 285) for episodes 6min...<1h, 99.6% (253/254) for episodes 1 h...<24h, 100% (71/71) for episodes >= 24h, or 97.5% for all episodes (595/610). The incidence of new-onset AF was 8.2% (119/1451), and in 31.1% of them (37/119), new-onset AF progressed to a higher duration stratum. Nearly 80% of new-onset AF patients had high CHA(2)DS(2)-VASc stroke risk, and 70% were not on anticoagulation therapy. Age was the only significant predictor of new-onset AF. Conclusion A 99.7% detection accuracy for AHRE >= 1h in patients with DX ICD systems in combination with daily RM allows a reliable guideline-recommended screening for subclinical AF and monitoring of AF-duration progression. [Graphics] .
引用
收藏
页数:10
相关论文
共 20 条
[1]   The role of atrial sensing for new-onset atrial arrhythmias diagnosis and management in single-chamber implantable cardioverter-defibrillator recipients: Results from the THINGS registry [J].
Biffi, Mauro ;
Iori, Matteo ;
De Maria, Elia ;
Bolognesi, Maria Giulia ;
Placci, Angelo ;
Calvi, Valeria ;
Allocca, Giuseppe ;
Ammendola, Ernesto ;
Carinci, Valeria ;
Boggian, Giulio ;
Saporito, Davide ;
Grassini, Diego ;
Giacopelli, Daniele ;
Statuto, Giovanni ;
Ziacchi, Matteo .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (04) :846-853
[2]   Detection of new atrial fibrillation in patients with cardiac implanted electronic devices and factors associated with transition to higher device-detected atrial fibrillation burden [J].
Boriani, Giuseppe ;
Glotzer, Taya V. ;
Ziegler, Paul D. ;
De Melis, Mirko ;
Stefano, Lorenza Mangoni di S. ;
Sepsi, Milan ;
Landolina, Maurizio ;
Lunati, Maurizio ;
Lewalter, Thorsten ;
Camm, A. John .
HEART RHYTHM, 2018, 15 (03) :376-383
[3]   Dual-Chamber Implantable Cardioverter-Defibrillator Selection Is Associated With Increased Complication Rates and Mortality Among Patients Enrolled in the NCDR Implantable Cardioverter-Defibrillator Registry [J].
Dewland, Thomas A. ;
Pellegrini, Cara N. ;
Wang, Yongfei ;
Marcus, Gregory M. ;
Keung, Edmund ;
Varosy, Paul D. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (10) :1007-1013
[4]   Arrhythmia Detection in Single- and Dual-Chamber Implantable Cardioverter Defibrillators: The More Leads, the Better? [J].
Francia, Pietro ;
Balla, Cristina ;
Uccellini, Arianna ;
Cappato, Riccardo .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2009, 20 (09) :1077-1082
[5]   Subclinical Atrial Fibrillation and the Risk of Stroke [J].
Healey, Jeff S. ;
Connolly, Stuart J. ;
Gold, Michael R. ;
Israel, Carsten W. ;
Van Gelder, Isabelle C. ;
Capucci, Alessandro ;
Lau, C. P. ;
Fain, Eric ;
Yang, Sean ;
Bailleul, Christophe ;
Morillo, Carlos A. ;
Carlson, Mark ;
Themeles, Ellison ;
Kaufman, Elizabeth S. ;
Hohnloser, Stefan H. .
NEW ENGLAND JOURNAL OF MEDICINE, 2012, 366 (02) :120-129
[6]   2020 ESC Guidelines for the diagnosis and management of atrial fibrillation developed in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS) [J].
Hindricks, Gerhard ;
Potpara, Tatjana ;
Dagres, Nikolaos ;
Arbelo, Elena ;
Bax, Jeroen J. ;
Blomstroem-Lundqvist, Carina ;
Boriani, Giuseppe ;
Castella, Manuel ;
Dan, Gheorghe-Andrei ;
Dilaveris, Polychronis E. ;
Fauchier, Laurent ;
Filippatos, Gerasimos ;
Kalman, Jonathan M. ;
La Meir, Mark ;
Lane, Deirdre A. ;
Lebeau, Jean-Pierre ;
Lettino, Maddalena ;
Lip, Gregory Y. H. ;
Pinto, Fausto J. ;
Thomas, G. Neil ;
Valgimigli, Marco ;
Van Gelder, Isabelle C. ;
Van Putte, Bart P. ;
Watkins, Caroline L. .
EUROPEAN HEART JOURNAL, 2021, 42 (05) :373-498
[7]   Implant-based multiparameter telemonitoring of patients with heart failure (IN-TIME): a randomised controlled trial [J].
Hindricks, Gerhard ;
Taborsky, Milos ;
Glikson, Michael ;
Heinrich, Ullus ;
Schumacher, Burghard ;
Katz, Amos ;
Brachmann, Johannes ;
Lewalter, Thorsten ;
Goette, Andreas ;
Block, Michael ;
Kautzner, Josef ;
Sack, Stefan ;
Husser, Daniela ;
Piorkowski, Christopher ;
Sogaard, Peter .
LANCET, 2014, 384 (9943) :583-590
[8]   Implantable Cardioverter Defibrillator System with Floating Atrial Sensing Dipole: A Single-Center Experience [J].
Iori, Matteo ;
Giacopelli, Daniele ;
Quartieri, Fabio ;
Bottoni, Nicola ;
Manari, Antonio .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2014, 37 (10) :1265-1273
[9]   Stroke Risk as a Function of Atrial Fibrillation Duration and CHA2DS2-VASc Score [J].
Kaplan, Rachel M. ;
Koehler, Jodi ;
Ziegler, Paul D. ;
Sarkar, Shantanu ;
Zweibel, Steven ;
Passman, Rod S. .
CIRCULATION, 2019, 140 (20) :1639-1646
[10]  
Kirchhof P, 2016, EUROPACE, V18, DOI [10.1093/europace/euw295, 10.5603/KP.2016.0172, 10.1016/j.rec.2016.11.033]