Evaluation of Accuracy and Performance of a Novel, Fully Gantry Integrated 3D Laser System for Computed Tomography Guided Needle Placement: A Phantom Study

被引:2
作者
Weigel, Katharina [1 ,2 ]
Kubik-Huch, Rahel A. [1 ]
Baer-Beck, Matthias [3 ]
Canstein, Christian [3 ]
Kostrzewa, Michael [1 ,4 ]
机构
[1] Baden Cantonal Hosp, Dept Radiol, CH-5404 Baden, Switzerland
[2] Barking Havering & Redbridge Univ Hosp NHS Trust, Romford RM7 0A, England
[3] Siemens Healthineers, D-91301 Forchheim, Germany
[4] Heidelberg Univ, Univ Hosp Mannheim, Inst Clin Radiol & Nucl Med, D-68167 Mannheim, Germany
关键词
computed tomography; intervention; laser-guidance; phantom; safety; radiation exposure;
D O I
10.3390/diagnostics13020282
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this phantom study was to compare the accuracy, speed and technical performance of CT guided needle placement using a conventional technique versus a novel, gantry integrated laser guidance system for both an expert and a novice. A total of 80 needle placements were performed in an abdominal phantom using conventional CT guidance and a laser guidance system. Analysis of pooled results of expert and novice showed a significant reduction of time (277 vs. 204 s, p = 0.001) and of the number of needle corrections (3.28 vs. 1.58, p < 0.001) required when using laser guidance versus conventional technique. No significant improvement in absolute (3.81 vs. 3.41 mm, p = 0.213) or angular deviation (2.85 vs. 2.18 degrees, p = 0.079) was found. With either approach, the expert was significantly faster (conventional guidance: 207 s vs. 346 s, p < 0.001; laser guidance: 144 s vs. 264 s, p < 0.001) and required fewer needle corrections (conventional guidance: 4 vs. 3, p = 0.027; laser guidance: 2 vs. 1, p = 0.001) than the novice. The laser guidance system helped both the expert and the novice to perform CT guided interventions in a phantom faster and with fewer needle corrections compared to the conventional technique, while achieving similar accuracy.
引用
收藏
页数:10
相关论文
共 19 条
[1]   Stereotactic Radiofrequency Ablation of Hepatocellular Carcinoma: a Histopathological Study in Explanted Livers [J].
Bale, Reto ;
Schullian, Peter ;
Eberle, Gernot ;
Putzer, Daniel ;
Zoller, Heinz ;
Schneeberger, Stefan ;
Manzl, Claudia ;
Moser, Patrizia ;
Oberhuber, Georg .
HEPATOLOGY, 2019, 70 (03) :840-850
[2]   Percutaneous stereotactic radiofrequency ablation of colorectal liver metastases [J].
Bale, Reto ;
Widmann, Gerlig ;
Schullian, Peter ;
Haidu, Marion ;
Pall, Georg ;
Klaus, Alexander ;
Weiss, Helmut ;
Biebl, Matthias ;
Margreiter, Raimund .
EUROPEAN RADIOLOGY, 2012, 22 (04) :930-937
[3]   Comparison of CT Fluoroscopy-Guided Manual and CT-Guided Robotic Positioning System for In Vivo Needle Placements in Swine Liver [J].
Cornelis, F. ;
Takaki, H. ;
Laskhmanan, M. ;
Durack, J. C. ;
Erinjeri, J. P. ;
Getrajdman, G. I. ;
Maybody, M. ;
Sofocleous, C. T. ;
Solomon, S. B. ;
Srimathveeravalli, G. .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2015, 38 (05) :1252-1260
[4]   Value of Interventional Radiology: Past, Present and Future [J].
Doherty, Michael G. .
SEMINARS IN INTERVENTIONAL RADIOLOGY, 2019, 36 (01) :26-28
[5]   Phantom and Animal Study of a Robot-Assisted, CT-Guided Targeting System using Image-Only Navigation for Stereotactic Needle Insertion without Positional Sensors [J].
Fong, Khi Yung ;
Tan, Alexander Sheng Ming ;
Sulaiman, Muhammad Syadad Bin ;
Leong, Siang Huei ;
Ng, Ka Wei ;
Too, Chow Wei .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2022, 33 (11) :1416-+
[6]   Computer tomography guided thoracoscopic resection of small pulmonary nodules in the hybrid theatre [J].
Karampinis, Ioannis ;
Rathmann, Nils ;
Kostrzewa, Michael ;
Diehl, Steffen J. ;
Schoenberg, Stefan O. ;
Hohenberger, Peter ;
Roessner, Eric D. .
PLOS ONE, 2021, 16 (11)
[7]   Robotic CT-guided out-of-plane needle insertion: comparison of angle accuracy with manual insertion in phantom and measurement of distance accuracy in animals [J].
Komaki, Toshiyuki ;
Hiraki, Takao ;
Kamegawa, Tetsushi ;
Matsuno, Takayuki ;
Sakurai, Jun ;
Matsuura, Ryutaro ;
Yamaguchi, Takuya ;
Sasaki, Takanori ;
Mitsuhashi, Toshiharu ;
Okamoto, Soichiro ;
Uka, Mayu ;
Matsui, Yusuke ;
Iguchi, Toshihiro ;
Gobara, Hideo ;
Kanazawa, Susumu .
EUROPEAN RADIOLOGY, 2020, 30 (03) :1342-1349
[8]   Robotic Assistance System for Cone-Beam Computed Tomography-Guided Percutaneous Needle Placement [J].
Kostrzewa, Michael ;
Rothfuss, Andreas ;
Patz, Torben ;
Kuhne, Markus ;
Schoenberg, Stefan O. ;
Diehl, Steffen J. ;
Stallkamp, Jan ;
Rathmann, Nils .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2022, 45 (01) :62-68
[9]   Computed Tomography-Assisted Thoracoscopic Surgery: A Novel, Innovative Approach in Patients With Deep Intrapulmonary Lesions of Unknown Malignant Status [J].
Kostrzewa, Michael ;
Kara, Kerim ;
Rathmann, Nils ;
Tsagogiorgas, Charalambos ;
Henzler, Thomas ;
Schoenberg, Stefan O. ;
Hohenberger, Peter ;
Diehl, Steffen J. ;
Roessner, Eric D. .
INVESTIGATIVE RADIOLOGY, 2017, 52 (06) :374-380
[10]   Accuracy of percutaneous soft-tissue interventions using a multi-axis, C-arm CT system and 3D laser guidance [J].
Kostrzewa, Michael ;
Rathmann, Nils ;
Kara, Kerim ;
Schoenberg, Stefan O. ;
Diehl, Steffen J. .
EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (10) :1970-1975