Fast Timing in Medical Imaging

被引:6
作者
Lecoq, P. [1 ,2 ,3 ]
Gonzalez, A. J. [2 ]
Auffray, E. [4 ]
Konstantinou, G. [1 ]
Nuyts, J. [5 ]
Prior, J. O. [6 ]
Turtos, R. M. [7 ]
Varela, J. [8 ]
机构
[1] Multiwave Metacrystal SA, CH-1228 Geneva, Switzerland
[2] Univ Politecn Valencia, Ctr Mixto, Inst Instrumentac Imagen Mol, CSIC, Valencia 46022, Spain
[3] European Org Nucl Res, CERN, CH-1211 Geneva, Switzerland
[4] European Org Nucl Res, DI Dept, CERN, CH-1211 Geneva, Switzerland
[5] Katholieke Univ Leuven, Nucl Med & Mol Imaging, MIRC, B-3000 Leuven, Belgium
[6] Lausanne Univ Hosp, Dept Nucl Med & Mol Imaging, CH-1011 Lausanne, Switzerland
[7] Aarhus Univ, Dept Phys & Astron, DK-8000 Aarhus, Denmark
[8] Univ Lisbon, LIP, P-1649004 Lisbon, Portugal
关键词
Biomedical imaging; Positron emission tomography; Timing; Imaging; Image reconstruction; Sensitivity; Crystals; Electronics; image reconstruction; medical imaging; metascintillator; photodetector; positron emission tomography (PET); scintillator heterostructure; scintillators; time-of-flight (TOF); COINCIDENCE-TIME-RESOLUTION; SCINTILLATION PROPERTIES; LUMINESCENCE; PERFORMANCE; DETECTORS; CRYSTALS; LIMITS; NOISE;
D O I
10.1109/TRPMS.2023.3259464
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We report in this article on the Fast Timing in Medical Imaging workshop, (Valencia, 2 June 2022). The workshop gathered 104 attendees from all over the world, with representatives from the academic and industrial sectors. During three very dense days, nuclear medicine physicians, radiologists, oncologists, immunologists, and biologists have debated with physicists, engineers, technologists of different disciplines, as well as with medical imaging industry representatives to devise about the importance of improving the timing performance of a new generation of medical imaging instrumentation, with a special focus on positron emission tomography scanners toward the ultimate goal of 10-ps coincidence time resolution (CTR), allowing a millimeter 3-D spatial resolution on an event-to-event basis by time-of-flight (TOF) techniques. This article summarizes the most up-to-date developments on the roadmap toward the 10-ps time of flight challenge based on the contributions to this workshop.
引用
收藏
页码:429 / 452
页数:24
相关论文
共 116 条
  • [1] Human- and model-observer performance in ramp-spectrum noise: effects of regularization and object variability
    Abbey, CK
    Barrett, HH
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2001, 18 (03): : 473 - 488
  • [2] Albuquerque E, 2021, PROC C REC IEEE NUCL, P1
  • [3] ALLEMAND R, 1980, J NUCL MED, V21, P153
  • [4] Lead tungstate scintillation material
    Annenkov, AA
    Korzhik, MV
    Lecoq, P
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 490 (1-2) : 30 - 50
  • [5] [Anonymous], 2019, CERNLHCC2019003 CMS
  • [6] First Cerenkov charge-induction (CCI) TlBr detector forTOF-PET and proton range verification
    Arino-Estrada, Gerard
    Mitchell, Gregory S.
    Kim, Hadong
    Du, Junwei
    Kwon, Sun Il
    Cirignano, Leonard J.
    Shah, Kanai S.
    Cherry, Simon R.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (17)
  • [7] A Comprehensive & Systematic Study of Coincidence Time Resolution and Light Yield Using Scintillators of Different Size and Wrapping
    Auffray, E.
    Frisch, B.
    Geraci, F.
    Ghezzi, A.
    Gundacker, S.
    Hillemanns, H.
    Jarron, P.
    Meyer, T.
    Paganoni, M.
    Pauwels, K.
    Pizzichemi, M.
    Lecoq, P.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (05) : 3163 - 3171
  • [8] Performance evaluation of MACACO II Compton camera
    Barrientos, L.
    Borja-Lloret, M.
    Etxebeste, A.
    Munoz, E.
    Oliver, J. F.
    Ros, A.
    Roser, J.
    Senra, C.
    Viegas, R.
    Llosa, G.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 1014
  • [9] Belcari N., 2022, FTMI WORKSHOP
  • [10] Evidence and Consequences of Ce4+ in LYSO:Ce, Ca and LYSO:Ce, Mg Single Crystals for Medical Imaging Applications
    Blahuta, S.
    Bessiere, A.
    Viana, B.
    Dorenbos, P.
    Ouspenski, V.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (04) : 3134 - 3141