INVERTED INTERNAL LIMITING MEMBRANE FLAP FOR SMALL-SIZED (<250 μm) FULL-THICKNESS MACULAR HOLE Anatomical and Functional Outcome

被引:8
|
作者
Iuliano, Lorenzo [1 ,2 ]
Corbelli, Eleonora [1 ]
Bandello, Francesco [1 ]
Codenotti, Marco [1 ]
机构
[1] Vite Salute Univ, San Raffaele Sci Inst, Dept Ophthalmol, Milan, Italy
[2] Vite Salute Univ, Osped San Raffaele Sci Inst, Dept Ophthalmol, Via Olgettina, 60, I-20132 Milan, Italy
来源
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES | 2023年 / 43卷 / 04期
关键词
small macular hole; intermediate macular hole; inverted ILM flap; cover technique; external limiting membrane; ellipsoid zone; RETINAL-DETACHMENT; SURGERY;
D O I
10.1097/IAE.0000000000003728
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose:To compare the anatomical and functional outcome of small (mu m) and medium (250-400 mu m) full-thickness macular holes (FTMHs) treated with internal limiting membrane (ILM) inverted flap (IF) or with the standard technique.Methods:Retrospective longitudinal analysis of successfully operated eyes with small or intermediate FTMH. Outcome measures were best-corrected visual acuity (BCVA), microperimetric sensitivity (with fixation stability), and restoration of the external limiting membrane (ELM) and ellipsoid zone (EZ) at 6 months.Results:Fifty small and 50 intermediate eyes with FTMH were included, half of each group (25) treated with the standard technique, half with IF. BCVA increased in every subgroup, similarly within the same stage regardless the technique. Small FTMH treated with IF disclosed inferior foveal sensitivity at 6 months (20.79 +/- 0.48 dB) compared with the standard technique (21.51 +/- 0.79 dB; P = 0.0035). At 1 month, inferior rates of ELM (24%) and EZ (24%) restoration were also found, compared with the standard technique (56% ELM P = 0.0420; 64% EZ P = 0.0095). At 6 months, ELM and EZ were similarly restored.Conclusion:The surgical repair of small FMTH with ILM IF seem to delay the foveal structural repair and to gain an inferior foveal sensitivity compared to the standard technique.
引用
收藏
页码:547 / 554
页数:8
相关论文
共 50 条
  • [41] Impact of the Inverted Internal Limiting Membrane Flap Diameter on Large Idiopathic Macular Hole Closure: Comparative Randomized Study
    Elwan, Mohamed M.
    Hagras, Sherein M.
    OPHTHALMIC SURGERY LASERS & IMAGING RETINA, 2022, 53 (02) : 103 - 107
  • [42] MANAGEMENT OF LARGE FULL-THICKNESS MACULAR HOLES: Long-Term Outcomes of Internal Limiting Membrane Flaps and Internal Limiting Membrane Peels
    Richards, Kaitlyn
    Kadakia, Ankit
    Wykoff, Charles C.
    Major, James C.
    Wong, Tien P.
    Chen, Eric
    Schefler, Amy C.
    Patel, Sagar B.
    Kim, Rosa Y.
    Henry, Christopher R.
    Fish, Richard H.
    Brown, David M.
    Benz, Matthew S.
    Pearce, William
    Shah, Ankoor R.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2024, 44 (07): : 1165 - 1170
  • [43] THE TEXAS TACO TECHNIQUE FOR INTERNAL LIMITING MEMBRANE FLAP IN LARGE FULL-THICKNESS MACULAR HOLES A Short-Term Pilot Study
    Major, James C., Jr.
    Lampen, Shaun I. R.
    Wykoff, Charles C.
    Ou, William C.
    Brown, David M.
    Wong, Tien P.
    Shah, Ankoor R.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2020, 40 (03): : 552 - 556
  • [44] Persistent Full-Thickness Idiopathic Macular Hole: Anatomical and Functional Outcome of Revitrectomy with Autologous Platelet Concentrate or Autologous Whole Blood
    Purtskhvanidze, Konstantine
    Fruehsorger, Brigitte
    Bartsch, Sofya
    Hedderich, Juergen
    Roider, Johann
    Treumer, Felix
    OPHTHALMOLOGICA, 2018, 239 (01) : 19 - 26
  • [45] Anatomical and functional results after vitrectomy with conventional ILM peeling versus inverted ILM flap technique in large full-thickness macular holes
    Dera, Adrianna U.
    Stoll, Doerte
    Schoeneberger, Verena
    Walckling, Marcus
    Brockmann, Claudia
    Fuchsluger, Thomas A.
    Schaub, Friederike
    INTERNATIONAL JOURNAL OF RETINA AND VITREOUS, 2023, 9 (01)
  • [46] Anatomical and functional results after vitrectomy with conventional ILM peeling versus inverted ILM flap technique in large full-thickness macular holes
    Adrianna U. Dera
    Doerte Stoll
    Verena Schoeneberger
    Marcus Walckling
    Claudia Brockmann
    Thomas A. Fuchsluger
    Friederike Schaub
    International Journal of Retina and Vitreous, 9
  • [47] Internal Limiting Membrane Peeling and Inverted Flap Technique in Macular Hole: Postoperative Metamorphopsia and Optical Coherence Tomography
    Murakami, Tomoya
    Okamoto, Fumiki
    Sugiura, Yoshimi
    Izumi, Iori
    Iioka, Aoi
    Morikawa, Shohei
    Hiraoka, Takahiro
    Oshika, Tetsuro
    OPHTHALMOLOGICA, 2024, 247 (02) : 107 - 117
  • [48] Inverted multi-layer internal limiting membrane flap for macular hole retinal detachment in high myopia
    Wang, Xianggui
    Zhu, Ying
    Xu, Huizhuo
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [49] Inverted flap technique versus internal limiting membrane insertion for macular hole in eyes with extremely high myopia
    Wu, Tsung-Tien
    Hou, Tzu-Yu
    Peng, Kai-Ling
    Kung, Ya-Hsin
    BMC OPHTHALMOLOGY, 2024, 24 (01)
  • [50] INFLUENCE OF INVERTED INTERNAL LIMITING MEMBRANE FLAP TECHNIQUE ON THE OUTER RETINAL LAYER STRUCTURES AFTER A LARGE MACULAR HOLE SURGERY
    Iwasaki, Masanori
    Kinoshita, Takamasa
    Miyamoto, Hirotomo
    Imaizumi, Hiroko
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2019, 39 (08): : 1470 - 1477