INVERTED INTERNAL LIMITING MEMBRANE FLAP FOR SMALL-SIZED (<250 μm) FULL-THICKNESS MACULAR HOLE Anatomical and Functional Outcome

被引:8
|
作者
Iuliano, Lorenzo [1 ,2 ]
Corbelli, Eleonora [1 ]
Bandello, Francesco [1 ]
Codenotti, Marco [1 ]
机构
[1] Vite Salute Univ, San Raffaele Sci Inst, Dept Ophthalmol, Milan, Italy
[2] Vite Salute Univ, Osped San Raffaele Sci Inst, Dept Ophthalmol, Via Olgettina, 60, I-20132 Milan, Italy
来源
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES | 2023年 / 43卷 / 04期
关键词
small macular hole; intermediate macular hole; inverted ILM flap; cover technique; external limiting membrane; ellipsoid zone; RETINAL-DETACHMENT; SURGERY;
D O I
10.1097/IAE.0000000000003728
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose:To compare the anatomical and functional outcome of small (mu m) and medium (250-400 mu m) full-thickness macular holes (FTMHs) treated with internal limiting membrane (ILM) inverted flap (IF) or with the standard technique.Methods:Retrospective longitudinal analysis of successfully operated eyes with small or intermediate FTMH. Outcome measures were best-corrected visual acuity (BCVA), microperimetric sensitivity (with fixation stability), and restoration of the external limiting membrane (ELM) and ellipsoid zone (EZ) at 6 months.Results:Fifty small and 50 intermediate eyes with FTMH were included, half of each group (25) treated with the standard technique, half with IF. BCVA increased in every subgroup, similarly within the same stage regardless the technique. Small FTMH treated with IF disclosed inferior foveal sensitivity at 6 months (20.79 +/- 0.48 dB) compared with the standard technique (21.51 +/- 0.79 dB; P = 0.0035). At 1 month, inferior rates of ELM (24%) and EZ (24%) restoration were also found, compared with the standard technique (56% ELM P = 0.0420; 64% EZ P = 0.0095). At 6 months, ELM and EZ were similarly restored.Conclusion:The surgical repair of small FMTH with ILM IF seem to delay the foveal structural repair and to gain an inferior foveal sensitivity compared to the standard technique.
引用
收藏
页码:547 / 554
页数:8
相关论文
共 50 条
  • [21] Large semicircular inverted internal limiting membrane flap in the treatment of macular hole in high myopia
    Chen, San-Ni
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2017, 255 (12) : 2337 - 2345
  • [22] Comparing the inverted internal limiting membrane flap with autologous blood technique to internal limiting membrane insertion for the repair of refractory macular hole
    Hu, Zhixiang
    Lin, Haishuang
    Liang, Qihua
    Wu, Ronghan
    INTERNATIONAL OPHTHALMOLOGY, 2020, 40 (01) : 141 - 149
  • [23] VISUAL OUTCOMES AFTER INTERNAL LIMITING MEMBRANE PEELING VERSUS FLAP IN THE CLOSURE OF FULL-THICKNESS MACULAR HOLES
    Suarez, Mallory K.
    Wang, Sean K.
    Hayes, Bartlett
    Greven, Margaret A.
    Shah, Rajiv E.
    Greven, Craig
    Russell, Greg
    Ong, Sally S.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2024, 44 (07): : 1171 - 1179
  • [24] Surgical outcomes of inverted internal limiting membrane flap technique for large macular hole
    Mahalingam, Prabhushanker
    Sambhav, Kumar
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2013, 61 (10) : 601 - U110
  • [25] Vitrectomy in Small idiopathic MAcuLar hoLe (SMALL) study: conventional internal limiting membrane peeling versus inverted flap
    Fallico, Matteo
    Caselgrandi, Paolo
    Marolo, Paola
    Parisi, Guglielmo
    Borrelli, Enrico
    Ricardi, Federico
    Gelormini, Francesco
    Ceroni, Luca
    Reibaldi, Michele
    EYE, 2024, 38 (17) : 3334 - 3340
  • [26] Inverted Internal Limiting Membrane Flap versus Internal Limiting Membrane Peeling for Macular Hole Retinal Detachment in High Myopia
    Matsumae, Hiroshi
    Morizane, Yuki
    Yamane, Shin
    Yanagisawa, Shuichiro
    Sakurai, Toshiya
    Kobori, Akira
    Imai, Hisanori
    Kanzaki, Yuki
    Suzuki, Etsuji
    Kadonosono, Kazuaki
    Hayashi, Atsushi
    Shiraga, Fumio
    Kuriyama, Shoji
    OPHTHALMOLOGY RETINA, 2020, 4 (09): : 919 - 926
  • [27] INVERTED INTERNAL LIMITING MEMBRANE FLAP TECHNIQUE FOR MACULAR HOLE SURGERY WITHOUT EXTRA MANIPULATION OF THE FLAP
    Casini, Giamberto
    Mura, Marco
    Figus, Michele
    Loiudice, Pasquale
    Peiretti, Enrico
    De Cilla, Stefano
    Fuentes, Taiusha
    Nasini, Francesco
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2017, 37 (11): : 2138 - 2144
  • [28] Visual improvement and regeneration of retinal layers in eyes with small, medium, and large idiopathic full-thickness macular holes treated with the inverted internal limiting membrane flap technique over a period of 12 months
    Nathalie Bleidißel
    Julia Friedrich
    Nikolaus Feucht
    Julian Klaas
    Mathias Maier
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2022, 260 : 3161 - 3171
  • [29] COMPARISON OF INTERNAL LIMITING MEMBRANE PEELING WITH THE INVERTED INTERNAL LIMITING MEMBRANE FLAP TECHNIQUE FOR RHEGMATOGENOUS RETINAL DETACHMENT COEXISTING WITH MACULAR HOLE
    Liu, Xujia
    Huang, Jinqu
    Zhou, Ruiqin
    Jiang, Zehua
    Chen, Haoyu
    Chen, Weiqi
    Ng, Tsz Kin
    Wu, Zhenggen
    Zhang, Guihua
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2022, 42 (04): : 697 - 703
  • [30] INVERTED INTERNAL LIMITING MEMBRANE FLAP TECHNIQUE FOR MACULAR HOLE COEXISTENT WITH RHEGMATOGENOUS RETINAL DETACHMENT
    Stappler, Theodor
    Montesel, Andrea
    Konstantinidis, Lazaros
    Wolfensberger, Thomas J.
    Eandi, Chiara M.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2022, 42 (08): : 1491 - 1497