Pulse wave analysis: basic concepts and clinical application in intensive care medicine

被引:7
作者
Thomsen, Kristen K. [1 ,3 ]
Kouz, Karim [1 ]
Saugel, Bernd [1 ,2 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Ctr Anesthesiol & Intens Care Med, Dept Anesthesiol, Hamburg, Germany
[2] Outcomes Res Consortium, Cleveland, OH USA
[3] Univ Med Ctr Hamburg Eppendorf, Ctr Anesthesiol & Intens Care Med, Dept Anesthesiol, Martinistr 52, D-20246 Hamburg, Germany
关键词
cardiac output-guided therapy; critically ill patients; hemodynamic management; hemodynamic monitoring; intensive care; pulse contour analysis; RECORDING ANALYTICAL METHOD; CARDIAC-OUTPUT ESTIMATION; BLOOD PRESSURE; FLUID RESPONSIVENESS; FORM ANALYSIS; ACCURACY; THERMODILUTION; CONTOUR; TECHNOLOGIES; VALIDATION;
D O I
10.1097/MCC.0000000000001039
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose of reviewThe measurement of cardiac output (CO) is important in patients with circulatory shock. Pulse wave analysis (PWA) estimates CO continuously and in real-time using the mathematical analysis of the arterial pressure waveform. We describe different PWA methods and provide a framework for CO monitoring using PWA in critically ill patients.Recent findingsPWA monitoring systems can be classified according to their invasiveness (into invasive, minimally invasive, and noninvasive systems) and their calibration method (into externally calibrated, internally calibrated, and uncalibrated systems). PWA requires optimal arterial pressure waveform signals. Marked alterations and rapid changes in systemic vascular resistance and vasomotor tone can impair the measurement performance of PWA.Noninvasive PWA methods are generally not recommended in critically ill patients (who have arterial catheters anyway). PWA systems can be used to continuously track stroke volume and CO in real-time during tests of fluid responsiveness or during therapeutic interventions. During fluid challenges, continuous CO monitoring is important because - if CO decreases - a fluid challenge can be stopped early to avoid further unnecessary fluid administration. PWA externally calibrated to indicator dilution methods can be used - in addition to echocardiography - to diagnose the type of shock.
引用
收藏
页码:215 / 222
页数:8
相关论文
共 64 条
  • [1] Accuracy of pulse pressure variations for fluid responsiveness prediction in mechanically ventilated patients with biphasic positive airway pressure mode
    Bataille, Benoit
    Le Moal, David
    Renault, Thomas
    Cocquet, Pierre
    de Selle, Jade
    Silva, Stein
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2022, 36 (05) : 1479 - 1487
  • [2] Performance of a new pulse contour method for continuous cardiac output monitoring: validation in critically ill patients
    Bendjelid, K.
    Marx, G.
    Kiefer, N.
    Simon, T. P.
    Geisen, M.
    Hoeft, A.
    Siegenthaler, N.
    Hofer, C. K.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2013, 111 (04) : 573 - 579
  • [3] Impact of Systemic Vascular Resistance on the Accuracy of the Pulsioflex Device
    Biais, Matthieu
    Mazocky, Elodie
    Stecken, Laurent
    Pereira, Bruno
    Sesay, Musa
    Roullet, Stephanie
    Quinart, Alice
    Sztark, Francois
    [J]. ANESTHESIA AND ANALGESIA, 2017, 124 (02) : 487 - 493
  • [4] Assessing the Diagnostic Accuracy of Pulse Pressure Variations for the Prediction of Fluid Responsiveness A "Gray Zone" Approach
    Cannesson, Maxime
    Le Manach, Yannick
    Hofer, Christoph K.
    Goarin, Jean Pierre
    Lehot, Jean-Jacques
    Vallet, Benoit
    Tavernier, Benoit
    [J]. ANESTHESIOLOGY, 2011, 115 (02) : 231 - 241
  • [5] Consensus on circulatory shock and hemodynamic monitoring. Task force of the European Society of Intensive Care Medicine
    Cecconi, Maurizio
    De Backer, Daniel
    Antonelli, Massimo
    Beale, Richard
    Bakker, Jan
    Hofer, Christoph
    Jaeschke, Roman
    Mebazaa, Alexandre
    Pinsky, Michael R.
    Teboul, Jean Louis
    Vincent, Jean Louis
    Rhodes, Andrew
    [J]. INTENSIVE CARE MEDICINE, 2014, 40 (12) : 1795 - 1815
  • [6] What is a fluid challenge?
    Cecconi, Maurizio
    Parsons, Anthony K.
    Rhodes, Andrew
    [J]. CURRENT OPINION IN CRITICAL CARE, 2011, 17 (03) : 290 - 295
  • [7] Chamos C, 2013, PERIOPER MED-LONDON, V2, DOI 10.1186/2047-0525-2-19
  • [8] A randomised trial of non-invasive cardiac output monitoring to guide haemodynamic optimisation in high risk patients undergoing urgent surgical repair of proximal femoral fractures (ClearNOF trial NCT02382185)
    Davies, S. J.
    Yates, D. R.
    Wilson, R. J. T.
    Murphy, Z.
    Gibson, A.
    Allgar, V.
    Collyer, T.
    [J]. PERIOPERATIVE MEDICINE, 2019, 8 (01)
  • [9] Alternatives to the Swan-Ganz catheter
    De Backer, Daniel
    Bakker, Jan
    Cecconi, Maurizio
    Hajjar, Ludhmila
    Liu, Da Wei
    Lobo, Suzanna
    Monnet, Xavier
    Morelli, Andrea
    Myatra, Sheila Neinan
    Perel, Azriel
    Pinsky, Michael R.
    Saugel, Bernd
    Teboul, Jean-Louis
    Vieillard-Baron, Antoine
    Vincent, Jean-Louis
    [J]. INTENSIVE CARE MEDICINE, 2018, 44 (06) : 730 - 741
  • [10] Noninvasive continuous beat-to-beat radial artery pressure via TL-200 applanation tonometry
    Dueck, Ron
    Goedje, Oliver
    Clopton, Paul
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2012, 26 (02) : 75 - 83