Diagnostic accuracy of contrast-enhanced ultrasound for detecting clinically significant portal hypertension and severe portal hypertension in chronic liver disease: a meta-analysis

被引:2
作者
Duan, Yayang [1 ]
Dong, Bingtian [1 ]
Li, Siyao [2 ]
Zhang, Chaoxue [1 ,3 ]
机构
[1] Anhui Med Univ, Affiliated Hosp 1, Dept Ultrasound, Hefei, Anhui, Peoples R China
[2] Qingdao Univ, Affiliated Yantai Yuhuangding Hosp, Dept Ultrasound, Yantai, Shandong, Peoples R China
[3] Anhui Med Univ, Affiliated Hosp 1, Dept Ultrasound, 218 Jixi Rd, Hefei 230022, Anhui, Peoples R China
关键词
Contrast-enhanced ultrasound; clinically significant portal hypertension; severe portal hypertension; subharmonic aided pressure estimation; meta-analysis; VENOUS-PRESSURE GRADIENT; DOPPLER ULTRASONOGRAPHY; SYSTEMATIC REVIEWS; FIBROSIS; DECOMPENSATION; STIFFNESS; AGENTS; TIME; TOOL;
D O I
10.1080/17474124.2023.2196402
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: Contrast-enhanced ultrasound (CEUS) has been proposed for detecting clinically significant portal hypertension (CSPH) and severe portal hypertension (SPH) in patients with chronic liver diseases (CLD). Research design & methods: Studies were selected that investigated the diagnostic performance of CEUS in patients with CLD up to 10 October 2022. The summary area under the receiver operating characteristic curve (AUROC), the summary diagnostic odds ratios, and the summary sensitivities and specificities were used to assess the performance of CEUS for detecting CSPH and SPH. Results: A total of 7 studies were included in this meta-analysis. The summary sensitivity and specificity of this method for CSPH were 92% (95% confidence interval (CI), 76%-97%) and 78% (95% CI, 67%-86%), respectively, and the summary AUROC was 0.89 (95% CI, 0.86-0.92). Those for SPH were 81% (95% CI, 60%-93%), 82% (95% CI, 76%-86%), and 0.82 (95% CI, 0.79-0.85), respectively. A subgroup analysis of 3 subharmonic aided pressure estimation (SHAPE) studies revealed similar diagnostic performance (sensitivity: 95%; specificity: 74%; AUROC: 0.93) for detecting CSPH. Conclusions: CEUS shows good performance in diagnosing CSPH as well as SPH. SHAPE technique may play a more important role in evaluating CSPH in the future.
引用
收藏
页码:489 / 497
页数:9
相关论文
共 43 条
  • [1] Haemodynamic evaluation by Doppler ultrasonography in patients with portal hypertension: a review
    Baik, Soon Koo
    [J]. LIVER INTERNATIONAL, 2010, 30 (10) : 1403 - 1413
  • [2] Non-invasive evaluation of portal hypertension using ultrasound elastography
    Berzigotti, Annalisa
    [J]. JOURNAL OF HEPATOLOGY, 2017, 67 (02) : 399 - 411
  • [3] Portal Hypertension: Pathophysiology, Diagnosis, and Treatment
    Buob, S.
    Johnston, A. N.
    Webster, C. R. L.
    [J]. JOURNAL OF VETERINARY INTERNAL MEDICINE, 2011, 25 (02): : 169 - 186
  • [4] Comparison of Doppler ultrasonography and the hepatic venous pressure gradient in assessing portal hypertension in liver cirrhosis
    Choi, YJ
    Baik, SK
    Park, DH
    Kim, MY
    Kim, HS
    Lee, DK
    Kwon, SO
    Kim, YJ
    Park, JW
    [J]. JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2003, 18 (04) : 424 - 429
  • [5] Ultrasound contrast agents: An overview
    Cosgrove, David
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2006, 60 (03) : 324 - 330
  • [6] A Combined Baveno VII and Spleen Stiffness Algorithm to Improve the Noninvasive Diagnosis of Clinically Significant Portal Hypertension in Patients With Compensated Advanced Chronic Liver Disease
    Dajti, Elton
    Ravaioli, Federico
    Marasco, Giovanni
    Alemanni, Luigina Vanessa
    Colecchia, Luigi
    Ferrarese, Alberto
    Cusumano, Caterina
    Gemini, Stefano
    Vestito, Amanda
    Renzulli, Matteo
    Golfieri, Rita
    Festi, Davide
    Colecchia, Antonio
    [J]. AMERICAN JOURNAL OF GASTROENTEROLOGY, 2022, 117 (11) : 1825 - 1833
  • [7] INVESTIGATING THE EFFICACY OF SUBHARMONIC AIDED PRESSURE ESTIMATION FOR PORTAL VEIN PRESSURES AND PORTAL HYPERTENSION MONITORING
    Dave, Jaydev K.
    Halldorsdottir, Valgerdur G.
    Eisenbrey, John R.
    Merton, Daniel A.
    Liu, Ji-Bin
    Zhou, Jian-Hua
    Wang, Hsin-Kai
    Park, Suhyun
    Dianis, Scott
    Chalek, Carl L.
    Lin, Feng
    Thomenius, Kai E.
    Brown, Daniel B.
    Forsberg, Flemming
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2012, 38 (10) : 1784 - 1798
  • [8] Baveno VII - Renewing consensus in portal hypertension
    de Franchis, Roberto
    Bosch, Jaime
    Garcia-Tsao, Guadalupe
    Reiberger, Thomas
    Ripoll, Cristina
    [J]. JOURNAL OF HEPATOLOGY, 2022, 76 (04) : 959 - 974
  • [9] The performance of tests of publication bias and other sample size effects in systematic reviews of diagnostic test accuracy was assessed
    Deeks, JJ
    Macaskill, P
    Irwig, L
    [J]. JOURNAL OF CLINICAL EPIDEMIOLOGY, 2005, 58 (09) : 882 - 893
  • [10] Chronic Liver Disease: Noninvasive Subharmonic Aided Pressure Estimation of Hepatic Venous Pressure Gradient
    Eisenbrey, John R.
    Dave, Jaydev K.
    Halldorsdottir, Valgerdur G.
    Merton, Daniel A.
    Miller, Cynthia
    Gonzalez, Jose M.
    Machado, Priscilla
    Park, Suhyun
    Dianis, Scott
    Chalek, Carl L.
    Kim, Christopher E.
    Baliff, Jeffrey P.
    Thomenius, Kai E.
    Brown, Daniel B.
    Navarro, Victor
    Forsberg, Flemming
    [J]. RADIOLOGY, 2013, 268 (02) : 581 - 588