Advances in High-Energy-Resolution CdZnTe Linear Array Pixel Detectors with Fast and Low Noise Readout Electronics
被引:12
|作者:
Mele, Filippo
[1
,2
]
Quercia, Jacopo
[1
]
Abbene, Leonardo
[3
]
Benassi, Giacomo
[4
]
Bettelli, Manuele
[5
]
Buttacavoli, Antonino
[3
]
Principato, Fabio
[3
]
Zappettini, Andrea
[5
]
Bertuccio, Giuseppe
[1
,2
]
机构:
[1] Politecn Milan, Dept Elect Informat & Bioengn DEIB, Via Anzani 42, I-22100 Como, Italy
[2] Natl Inst Nucl Phys INFN, Sez Milano, Via Celoria 16, I-22133 Milan, Italy
[3] Univ Palermo, Dept Phys & Chem DiFC Emilio Segre, Viale Sci,Edificio 18, I-90128 Palermo, Italy
[4] Due2lab srl, Via Paolo Borsellino 2, I-42019 Scandiano, Italy
[5] CNR, IMEM, Parco Area Sci 37-A, I-43100 Parma, Italy
来源:
关键词:
CZT;
CdZnTe;
X-ray spectroscopy;
Gamma-ray spectroscopy;
semiconductor radiation detectors;
nuclear microelectronics;
GAMMA-RAY SPECTROSCOPY;
X-RAY;
CHARGE AMPLIFIERS;
CDTE;
PREAMPLIFIER;
OPTIMIZATION;
PERFORMANCE;
SIRIO;
D O I:
10.3390/s23042167
中图分类号:
O65 [分析化学];
学科分类号:
070302 ;
081704 ;
摘要:
Radiation detectors based on Cadmium Zinc Telluride (CZT) compounds are becoming popular solutions thanks to their high detection efficiency, room temperature operation, and to their reliability in compact detection systems for medical, astrophysical, or industrial applications. However, despite a huge effort to improve the technological process, CZT detectors' full potential has not been completely exploited when both high spatial and energy resolution are required by the application, especially at low energies (<10 keV), limiting their application in energy-resolved photon counting (ERPC) systems. This gap can also be attributed to the lack of dedicated front-end electronics which can bring out the best in terms of detector spectroscopic performances. In this work, we present the latest results achieved in terms of energy resolution using SIRIO, a fast low-noise charge sensitive amplifier, and a linear-array pixel detector, based on boron oxide encapsulated vertical Bridgman-grown B-VB CZT crystals. The detector features a 0.25-mm pitch, a 1-mm thickness and is operated at a -700-V bias voltage. An equivalent noise charge of 39.2 el. r.m.s. (corresponding to 412 eV FWHM) was measured on the test pulser at 32 ns peaking time, leading to a raw resolution of 1.3% (782 eV FWHM) on the 59 keV line at room temperature (+20 degrees C) using an uncollimated Am-241, largely improving the current state of the art for CZT-based detection systems at such short peaking times, and achieving an optimum resolution of 0.97% (576 eV FWHM) at 1 mu s peaking time. The measured energy resolution at the 122 keV line and with 1 mu s peaking time of a Co-57 raw uncollimated spectrum is 0.96% (1.17 keV). These activities are in the framework of an Italian collaboration on the development of energy-resolved X-ray scanners for material recycling, medical applications, and non-destructive testing in the food industry.