Assessment of physiological states from contactless face video: a sparse representation approach

被引:10
作者
Qayyum, Abdul [1 ]
Mazher, Moona [2 ]
Nuhu, Aliyu [3 ]
Benzinou, Abdesslam [4 ]
Malik, Aamir Saeed [5 ]
Razzak, Imran [6 ]
机构
[1] Univ Bourgogne, Dijon, France
[2] ENIB, UMR CNRS 6285 LabSTICC, F-29238 Brest, France
[3] Univ Rovira & Virgili, DEIM, Tarragona, Spain
[4] Univ Jos, Dept Elect & Elect Engn, Jos, Nigeria
[5] Univ Teknol Petronas, Ctr Intelligent Signal & Imaging Res CISIR, Dept Elect & Elect Engn, Seri Iskandar, Perak, Malaysia
[6] Deakin Univ, Sch Informat Technol, Geelong, Vic, Australia
关键词
Physiological; Fatigue; Health monitoring; Sparse representation; COVID-19;
D O I
10.1007/s00607-021-01028-3
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
The vital signs are estimated from remote photoplethysmography (rPPG) using the sparse representation signal reconstruction approach. The rPPG signal is used to estimate the physical parameters with the help of a non-invasive smartphone camera. This paper presents a health monitoring method by estimating vital signs using an RGB video camera and uses a pre-specified dictionary based on a hybrid discrete ridgelet transform with a Ricker wavelet basis function, to reconstruct a sparse signal prone to less error. The physical parameters such as heart rate (HR), breathing rate (BR), heart rate variability (HRV), and SpO2 are estimated using a smartphone video camera with the proposed sparse signal reconstruction technique. The inter-beat intervals (IBIs) are used to extract the power ratio in the frequency domain. Changes in HRV are more discriminative indicators of cognitive stress than those in HR and BR. The physiological states such as stress and fatigue could be measured using IBIs ratio in the frequency domain. The morning and evening dataset sessions are recruited for this experiment to check the stress and fatigue factors based on the power ratio extracted from the IBI signal. In the results, a lower mean absolute probability error value shows that the proposed method produces better results than state-of-the-art methods.
引用
收藏
页码:761 / 781
页数:21
相关论文
共 46 条
[1]  
Aznaveh MM, 2009, ADV INTEL SOFT COMPU, V60, P471
[2]   An ultra low power pulse oximeter sensor based on compressed sensing [J].
Baheti, Pawan K. ;
Garudadri, Harinath .
SIXTH INTERNATIONAL WORKSHOP ON WEARABLE AND IMPLANTABLE BODY SENSOR NETWORKS, PROCEEDINGS, 2009, :144-148
[3]   Remote assessment of the Heart Rate Variability to detect mental stress [J].
Bousefsaf, Frederic ;
Maaoui, Choubeila ;
Pruski, Alain .
PROCEEDINGS OF THE 2013 7TH INTERNATIONAL CONFERENCE ON PERVASIVE COMPUTING TECHNOLOGIES FOR HEALTHCARE AND WORKSHOPS (PERVASIVEHEALTH 2013), 2013, :348-351
[4]   Orthogonal Matching Pursuit for Sparse Signal Recovery With Noise [J].
Cai, T. Tony ;
Wang, Lie .
IEEE TRANSACTIONS ON INFORMATION THEORY, 2011, 57 (07) :4680-4688
[5]   Principal component analysis in ECG signal processing [J].
Castells, Francisco ;
Laguna, Pablo ;
Soernmo, Leif ;
Bollmann, Andreas ;
Roig, José Millet .
EURASIP JOURNAL ON ADVANCES IN SIGNAL PROCESSING, 2007, 2007 (1)
[6]   Detection of atrial fibrillation using contactless facial video monitoring [J].
Couderc, Jean-Philippe ;
Kyal, Survi ;
Mestha, Lalit K. ;
Xu, Beilei ;
Peterson, Derick R. ;
Xia, Xiaojuan ;
Hall, Burr .
HEART RHYTHM, 2015, 12 (01) :195-201
[7]   Analysis of Orthogonal Matching Pursuit Using the Restricted Isometry Property [J].
Davenport, Mark A. ;
Wakin, Michael B. .
IEEE TRANSACTIONS ON INFORMATION THEORY, 2010, 56 (09) :4395-4401
[8]   Improved motion robustness of remote-PPG by using the blood volume pulse signature [J].
de Haan, G. ;
van Leest, A. .
PHYSIOLOGICAL MEASUREMENT, 2014, 35 (09) :1913-1926
[9]   Robust Pulse Rate From Chrominance-Based rPPG [J].
de Haan, Gerard ;
Jeanne, Vincent .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (10) :2878-2886
[10]   Sparse signal reconstruction from limited data using FOCUSS: A re-weighted minimum norm algorithm [J].
Gorodnitsky, IF ;
Rao, BD .
IEEE TRANSACTIONS ON SIGNAL PROCESSING, 1997, 45 (03) :600-616